Repository navigation
Keep units with a numeric factor, such as meV*angstrom - #310
Merged
Merged
Conversation
Scipp writes a unit it has no name for with a numeric factor, e.g. meV*angstrom as 1.602176634e-32 J*m. EasyScience strips that factor whenever it creates a DescriptorNumber or Parameter, including every arithmetic result, so the unit became J*m and the value was rescaled: Parameter(value=0.1, unit='meV*angstrom') had the value 1.6e-33, a value set later was read in J*m, and 2 meV * 3 angstrom gave 9.6e-32 J*m. A temporary patch of EasyScience's DescriptorNumber._base_unit, applied when easydynamics is imported, now strips only a unit that is just a number (1000 from m/mm still becomes dimensionless) and keeps any other. Values, bounds and arithmetic results keep their unit, at no extra cost. Co-Authored-By: Claude Opus 5.5 <[email protected]>
Codecov Report✅ All modified and coverable lines are covered by tests. Additional details and impacted files@@ Coverage Diff @@
## develop #310 +/- ##
===========================================
+ Coverage 98.27% 98.28% +0.01%
===========================================
Files 65 66 +1
Lines 6548 6593 +45
Branches 1105 1113 +8
===========================================
+ Hits 6435 6480 +45
Misses 60 60
Partials 53 53
Flags with carried forward coverage won't be shown. Click here to find out more.
🚀 New features to boost your workflow:
|
Scipp gives a ratio of compatible units with different prefixes a unit that is only a number, above or below 1 (1000 for m/mm, 0.001 for mm/m, 1.6e-22 for meV/J). Cover a range of them, and a ratio of unrelated units, which keeps its unit. Co-Authored-By: Claude Opus 5.5 <[email protected]>
henrikjacobsenfys
added a commit
that referenced
this pull request
Nov 24, 2026
With #310, a Parameter created with a unit such as meV*angstrom keeps its value, so make_parameter_Q_independent, set_parameter_Q_dependence and ModelBase.from_dict no longer set the unit after construction. The shared relabel_parameter_unit helper this PR added for them is dropped again; ExpressionComponent.set_unit, which relabels a unit on purpose, keeps its own copy as on develop. Co-Authored-By: Claude Opus 5.5 <[email protected]>
henrikjacobsenfys
added a commit
that referenced
this pull request
Nov 24, 2026
* Add get_parameters, fix_parameter and free_parameter to ModelBase Address one Parameter of a named component at every Q, or at a single Q, without looping over the per-Q component collections by hand. Fixing or freeing at every Q also updates the template, so it survives a rebuild. Part of #70. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Add make_parameter_Q_independent to ModelBase Tie one Parameter of a named component to a single value across Q, by making it at every other Q dependent on the one at Q index 0. The model stores the tie and reapplies it whenever the per-Q collections are rebuilt or patched. remove_parameter_Q_constraint undoes it. Part of #70. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Add set_parameter_Q_dependence to ModelBase Make one Parameter of a named component follow an expression in Q, in terms of new Parameters owned by the model and shared by all Q. Units are carried through the expression by EasyScience. The model stores the dependence and reapplies it whenever the per-Q collections are rebuilt or patched. Part of #70. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Test the error for a dependent parameter; do not pin a library message The description promises that fixing a dependent parameter raises the EasyScience AttributeError; that is now tested. Two tests matched the full text of an EasyScience KeyError and only need the missing name. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Drop Q constraints with their component in two more cases Found by an independent review, each reproduced with a script. - A constraint on a component generated by a diffusion model outlived remove_diffusion_model, and remove_parameter_Q_constraint then raised a KeyError. SampleModel recorded the diffusion models' versions after the base class reapplied the constraints, which it skips while the collections count as stale. The two lines are swapped. - clear_components without Q kept the constraint for a later component of the same name, since pruning only runs on per-Q collections. clear_components now clears the constraints. Also: say in the docstring which fixed flags a removed constraint leaves, and drop a test that repeated get_parameters' own. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Keep the value of a new Parameter whose unit has a numeric factor Found by an independent review and reproduced with scripts. set_parameter_Q_dependence created its Parameters with the unit in the constructor. EasyScience rewrites a unit such as meV*angstrom**2 in base units and rescales the value with it, so {'D': 0.1} came back as 1.6e-43 kN*L, setting D.value afterwards gave widths of about 1e41 meV, and a fit failed with NaN. The unit is now set after construction with the relabelling ExpressionComponent already used, which moves to utils.relabel_parameter_unit. Also: - make_parameter_Q_independent replaces an existing Q dependence, as the description says and as the reverse already did; it raised. - remove_parameter_Q_constraint restores the bounds of the template. The parameters kept those of the expression, so a width was left without a lower bound. - clear_components clears the Q dependences too. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Test removing a Q constraint from a diffusion-model component Such a component has no template, so there are no template bounds to restore. Codecov flagged that branch as not covered. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Keep Q-independent parameters when copying or serializing a model copy and to_dict/from_dict re-create a model from its __init__ arguments, so constraints added with make_parameter_Q_independent were lost. to_dict now writes them under 'Q_independent_parameters', and from_dict reapplies them after construction. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Keep Q dependences when copying or serializing a model to_dict now writes each set_parameter_Q_dependence as its expression and its shared Parameters, and from_dict reinstates them, so the copy follows its own Parameters. The Parameters are read without their unit and relabelled afterwards, because EasyScience rescales the value of a Parameter created with a unit such as meV*angstrom. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Treat a Q-independent Parameter as a constant Q dependence make_parameter_Q_independent now makes the Parameter at every Q depend on one new model-owned Parameter, '<component> <parameter> (all Q)', which starts from the value, unit, bounds and fixed flag at Q index 0 and is returned. This drops the separate list of Q-independent parameters, its branch in _apply_Q_constraints and remove_parameter_Q_constraint, the Q index 0 special case in _get_parameters_with_template, and its own serialization key; Q-independent and Q-dependent Parameters now share one store and one code path. As for a Q dependence, the per-Q Parameters are all dependent, so they are set, fixed and bounded through the returned Parameter; fix_parameter on them raises. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Show how to build a diffusion model yourself in tutorial 1 A new section at the end makes the Lorentzian area Q-independent and its width follow hbar * D * Q**2, fits all Q simultaneously, and gets the same D and scale as the prebuilt BrownianTranslationalDiffusion model. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Store each Q dependence as a small named record _Q_dependences mapped each parameter to a bare (expression, parameters) tuple, read as dependence[0] and dependence[1]. A _QDependence dataclass with expression and parameters fields makes the type and its uses easier to read, and the key is unpacked by name instead of as key[0]. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Keep units with a numeric factor, such as meV*angstrom Scipp writes a unit it has no name for with a numeric factor, e.g. meV*angstrom as 1.602176634e-32 J*m. EasyScience strips that factor whenever it creates a DescriptorNumber or Parameter, including every arithmetic result, so the unit became J*m and the value was rescaled: Parameter(value=0.1, unit='meV*angstrom') had the value 1.6e-33, a value set later was read in J*m, and 2 meV * 3 angstrom gave 9.6e-32 J*m. A temporary patch of EasyScience's DescriptorNumber._base_unit, applied when easydynamics is imported, now strips only a unit that is just a number (1000 from m/mm still becomes dimensionless) and keeps any other. Values, bounds and arithmetic results keep their unit, at no extra cost. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Test that every ratio of compatible units stays dimensionless Scipp gives a ratio of compatible units with different prefixes a unit that is only a number, above or below 1 (1000 for m/mm, 0.001 for mm/m, 1.6e-22 for meV/J). Cover a range of them, and a ratio of unrelated units, which keeps its unit. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Build Parameters with their unit directly, now that units are kept With #310, a Parameter created with a unit such as meV*angstrom keeps its value, so make_parameter_Q_independent, set_parameter_Q_dependence and ModelBase.from_dict no longer set the unit after construction. The shared relabel_parameter_unit helper this PR added for them is dropped again; ExpressionComponent.set_unit, which relabels a unit on purpose, keeps its own copy as on develop. Co-Authored-By: Claude Opus 5.5 <[email protected]> --------- Co-authored-by: Claude Fable 5.2 <[email protected]>
henrikjacobsenfys
added a commit
that referenced
this pull request
Nov 24, 2026
* Add get_parameters, fix_parameter and free_parameter to ModelBase Address one Parameter of a named component at every Q, or at a single Q, without looping over the per-Q component collections by hand. Fixing or freeing at every Q also updates the template, so it survives a rebuild. Part of #70. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Add make_parameter_Q_independent to ModelBase Tie one Parameter of a named component to a single value across Q, by making it at every other Q dependent on the one at Q index 0. The model stores the tie and reapplies it whenever the per-Q collections are rebuilt or patched. remove_parameter_Q_constraint undoes it. Part of #70. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Add set_parameter_Q_dependence to ModelBase Make one Parameter of a named component follow an expression in Q, in terms of new Parameters owned by the model and shared by all Q. Units are carried through the expression by EasyScience. The model stores the dependence and reapplies it whenever the per-Q collections are rebuilt or patched. Part of #70. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Allow exp, sin, cos and sinc in set_parameter_Q_dependence EasyScience cannot apply functions to a Parameter in a dependency expression yet. Until it can, map callable DescriptorNumbers to the function names in the dependency map, so the expression calls those. Part of #70. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Test the error for a dependent parameter; do not pin a library message The description promises that fixing a dependent parameter raises the EasyScience AttributeError; that is now tested. Two tests matched the full text of an EasyScience KeyError and only need the missing name. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Drop Q constraints with their component in two more cases Found by an independent review, each reproduced with a script. - A constraint on a component generated by a diffusion model outlived remove_diffusion_model, and remove_parameter_Q_constraint then raised a KeyError. SampleModel recorded the diffusion models' versions after the base class reapplied the constraints, which it skips while the collections count as stale. The two lines are swapped. - clear_components without Q kept the constraint for a later component of the same name, since pruning only runs on per-Q collections. clear_components now clears the constraints. Also: say in the docstring which fixed flags a removed constraint leaves, and drop a test that repeated get_parameters' own. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Keep the value of a new Parameter whose unit has a numeric factor Found by an independent review and reproduced with scripts. set_parameter_Q_dependence created its Parameters with the unit in the constructor. EasyScience rewrites a unit such as meV*angstrom**2 in base units and rescales the value with it, so {'D': 0.1} came back as 1.6e-43 kN*L, setting D.value afterwards gave widths of about 1e41 meV, and a fit failed with NaN. The unit is now set after construction with the relabelling ExpressionComponent already used, which moves to utils.relabel_parameter_unit. Also: - make_parameter_Q_independent replaces an existing Q dependence, as the description says and as the reverse already did; it raised. - remove_parameter_Q_constraint restores the bounds of the template. The parameters kept those of the expression, so a width was left without a lower bound. - clear_components clears the Q dependences too. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Test removing a Q constraint from a diffusion-model component Such a component has no template, so there are no template bounds to restore. Codecov flagged that branch as not covered. Co-Authored-By: Claude Fable 5.2 <[email protected]> * Keep Q-independent parameters when copying or serializing a model copy and to_dict/from_dict re-create a model from its __init__ arguments, so constraints added with make_parameter_Q_independent were lost. to_dict now writes them under 'Q_independent_parameters', and from_dict reapplies them after construction. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Keep Q dependences when copying or serializing a model to_dict now writes each set_parameter_Q_dependence as its expression and its shared Parameters, and from_dict reinstates them, so the copy follows its own Parameters. The Parameters are read without their unit and relabelled afterwards, because EasyScience rescales the value of a Parameter created with a unit such as meV*angstrom. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Treat a Q-independent Parameter as a constant Q dependence make_parameter_Q_independent now makes the Parameter at every Q depend on one new model-owned Parameter, '<component> <parameter> (all Q)', which starts from the value, unit, bounds and fixed flag at Q index 0 and is returned. This drops the separate list of Q-independent parameters, its branch in _apply_Q_constraints and remove_parameter_Q_constraint, the Q index 0 special case in _get_parameters_with_template, and its own serialization key; Q-independent and Q-dependent Parameters now share one store and one code path. As for a Q dependence, the per-Q Parameters are all dependent, so they are set, fixed and bounded through the returned Parameter; fix_parameter on them raises. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Show how to build a diffusion model yourself in tutorial 1 A new section at the end makes the Lorentzian area Q-independent and its width follow hbar * D * Q**2, fits all Q simultaneously, and gets the same D and scale as the prebuilt BrownianTranslationalDiffusion model. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Mention the dependency functions in tutorial 1 Co-Authored-By: Claude Opus 5.5 <[email protected]> * Store each Q dependence as a small named record _Q_dependences mapped each parameter to a bare (expression, parameters) tuple, read as dependence[0] and dependence[1]. A _QDependence dataclass with expression and parameters fields makes the type and its uses easier to read, and the key is unpacked by name instead of as key[0]. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Keep units with a numeric factor, such as meV*angstrom Scipp writes a unit it has no name for with a numeric factor, e.g. meV*angstrom as 1.602176634e-32 J*m. EasyScience strips that factor whenever it creates a DescriptorNumber or Parameter, including every arithmetic result, so the unit became J*m and the value was rescaled: Parameter(value=0.1, unit='meV*angstrom') had the value 1.6e-33, a value set later was read in J*m, and 2 meV * 3 angstrom gave 9.6e-32 J*m. A temporary patch of EasyScience's DescriptorNumber._base_unit, applied when easydynamics is imported, now strips only a unit that is just a number (1000 from m/mm still becomes dimensionless) and keeps any other. Values, bounds and arithmetic results keep their unit, at no extra cost. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Test that every ratio of compatible units stays dimensionless Scipp gives a ratio of compatible units with different prefixes a unit that is only a number, above or below 1 (1000 for m/mm, 0.001 for mm/m, 1.6e-22 for meV/J). Cover a range of them, and a ratio of unrelated units, which keeps its unit. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Build Parameters with their unit directly, now that units are kept With #310, a Parameter created with a unit such as meV*angstrom keeps its value, so make_parameter_Q_independent, set_parameter_Q_dependence and ModelBase.from_dict no longer set the unit after construction. The shared relabel_parameter_unit helper this PR added for them is dropped again; ExpressionComponent.set_unit, which relabels a unit on purpose, keeps its own copy as on develop. Co-Authored-By: Claude Opus 5.5 <[email protected]> * Use sinc in the Chudley-Elliott width, so the jump length keeps its unit The width expression wrote sin(x)/x out with the jump length's bare value, since sin could not take a Parameter, so it assumed angstrom: converting the jump length to nm made the widths about 100 times too small. It now uses sinc from the dependency functions on Q * l with units, which also resolves the TODO waiting for sinc (#272). Co-Authored-By: Claude Opus 5.5 <[email protected]> * Add canary tests that fail once EasyScience no longer needs the workarounds One test per dependency function checks that EasyScience still cannot apply exp, sin, cos or sinc to a Parameter, and one checks that, without the unit patch, EasyScience still rescales meV*angstrom to J*m. When EasyScience is fixed they fail, and their docstrings say what to remove. The unit patch keeps EasyScience's own _base_unit for this. Co-Authored-By: Claude Opus 5.5 <[email protected]> --------- Co-authored-by: Claude Fable 5.2 <[email protected]>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Problem
Scipp writes a unit it has no name for with a numeric factor:
meV*angstromis1.602176634e-32 J*m. EasyScience strips that factor whenever it creates aDescriptorNumberorParameter, including the result of every arithmetic operation, and rescales the value to match. The value is physically the same, but the number changes silently:Parameter(value=0.1, unit='meV*angstrom')1.6e-33 J*m0.1 meV*Åparameter.value = 0.2J*mmeV*ÅParameter.from_dict(p.to_dict())2 meV * 3 Å9.6e-32 J*m6 meV*ÅE * L / L3.2e-22 J2 meV(2 meV)**21.03e-43 J^24 meV^21 m / 1 mm1000dimensionless1000dimensionless (unchanged)The stripping exists for the last row: a unit that is only a number, such as
1000fromm/mm, should become dimensionless.Change
easydynamics/base_unit_patch.pyreplaces EasyScience'sDescriptorNumber._base_unit, the unit a new object is converted to, with one that strips only a unit that is just a number and keeps any other. It is applied first thing wheneasydynamicsis imported.DescriptorNumberandParameterin the process, not only ours. Overriding_base_unitin our subclasses alone is not enough: EasyScience builds arithmetic results with its own classes.meV*angstrom**2as1.6e-42*kN*L. Only the value is affected by this PR.Not covered: two EasyDynamics
DescriptorNumbers still cannot be added, subtracted, multiplied or divided, because EasyScience only accepts its own exact class there. Our code never does this.Follow-up
Once merged, #299 can drop its three workarounds that set a unit after construction (in
make_parameter_Q_independent,set_parameter_Q_dependenceandModelBase.from_dict), about 20 lines.Tests
tests/unit/easydynamics/test_base_unit_patch.py: construction, setting a value,to_dict/from_dict, arithmetic (product, chain, power), and a dependency withoutdesired_unit. The pure-number case is tested over 13 ratios: scipp gives any ratio of compatible units with different prefixes a unit that is only a number, above or below 1 (1000form/mm,0.001formm/m,1.6e-22formeV/J,0.1formeV*angstrom / meV*nm), and all must stay dimensionless. A ratio of unrelated units (meV/THz) keeps its unit.Without the patch, 8 tests fail; the ratio tests pass either way, as that behaviour is unchanged. All unit tests and tutorial notebooks pass.
🤖 Generated with Claude Code