Skip to content

FitterWorker.stop() docstring describes removed thread-termination behavior #324

Closed

Description

@rozyczko

Source: EasyReflectometryApp/Backends/Py/workers/fitter_worker.py:137-160 — DEEP_ANALYSIS.md §5 item 13

stop()'s docstring describes QThread.terminate() behaviour and refers to THREAD_TERMINATION_WARNING.md, but:

  • the method only sets a flag (no termination), and
  • that file does not exist in the repository.

The docstring documents code that was removed. Relatedly, analysis.py:448 still calls setTerminationEnabled(True) although nothing terminates.

Fix: Update the docstring to describe the flag-based stop; remove the stale setTerminationEnabled(True) call and the nonexistent-file reference.

Activity

  1. added
    [scope] maintenance
    [priority] low
    on Jun 17, 2026
  2. added a commit that references this issue on Jun 18, 2026
  3. added a commit that references this issue on Jul 15, 2026
  4. added a commit that references this issue on Oct 19, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment