You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Test Failure tracing\\eventpipe\\enabledisable\\enabledisable\\enabledisable.cmd #83359
coreclr windows arm64 Checked gcstress0x3 @ Windows.11.Arm64.Open
- tracing\\eventpipe\\enabledisable\\enabledisable\\enabledisable.cmd
coreclr linux arm Checked gcstress0x3 @ (Ubuntu.1804.Arm32.Open)[email protected]/dotnet-buildtools/prereqs:ubuntu-18.04-helix-arm32v7
- tracing/eventpipe/enabledisable/enabledisable/enabledisable.sh
Error message:
cmdLine:C:\h\w\B6C009D4\w\B1690976\e\tracing\eventpipe\enabledisable\enabledisable\enabledisable.cmd Timed Out (timeout in milliseconds: 3600000 from variable __TestTimeout, start: 3/5/2023 3:30:55 PM, end: 3/5/2023 4:30:55 PM)
Return code: -100
Raw output file: C:\h\w\B6C009D4\w\B1690976\uploads\Reports\tracing.eventpipe\enabledisable\enabledisable\enabledisable.output.txt
Raw output:
BEGIN EXECUTION
"C:\h\w\B6C009D4\p\corerun.exe" -p "System.Reflection.Metadata.MetadataUpdater.IsSupported=false" enabledisable.dll
cmdLine:C:\h\w\B6C009D4\w\B1690976\e\tracing\eventpipe\enabledisable\enabledisable\enabledisable.cmd Timed Out (timeout in milliseconds: 3600000 from variable __TestTimeout, start: 3/5/2023 3:30:55 PM, end: 3/5/2023 4:30:55 PM)
Unable to find cdb.exe at C:\Program Files (x86)\Windows Kits\10\Debuggers\arm64\cdb.exe
Test Harness Exitcode is : -100
To run the test:
set CORE_ROOT=C:\h\w\B6C009D4\p
C:\h\w\B6C009D4\w\B1690976\e\tracing\eventpipe\enabledisable\enabledisable\enabledisable.cmd
Expected: True
Actual: False
Stack trace
at tracing_eventpipe._enabledisable_enabledisable_enabledisable_._enabledisable_enabledisable_enabledisable_cmd()
at System.RuntimeMethodHandle.InvokeMethod(Object target, Void** arguments, Signature sig, Boolean isConstructor)
at System.Reflection.MethodInvoker.Invoke(Object obj, IntPtr* args, BindingFlags invokeAttr)
coreclr linux arm Checked gcstress0x3 @ (Ubuntu.1804.Arm32.Open)[email protected]/dotnet-buildtools/prereqs:ubuntu-18.04-helix-arm32v7
- tracing/eventpipe/enabledisable/enabledisable/enabledisable.sh
Error message:
cmdLine:/root/helix/work/workitem/e/tracing/eventpipe/enabledisable/enabledisable/enabledisable.sh Timed Out (timeout in milliseconds: 3600000 from variable __TestTimeout, start: 3/12/2023 2:41:17 PM, end: 3/12/2023 3:41:17 PM)
Return code: -100
Raw output file: /root/helix/work/workitem/uploads/Reports/tracing.eventpipe/enabledisable/enabledisable/enabledisable.output.txt
Raw output:
BEGIN EXECUTION
/root/helix/work/correlation/corerun -p System.Reflection.Metadata.MetadataUpdater.IsSupported=false enabledisable.dll ''
cmdLine:/root/helix/work/workitem/e/tracing/eventpipe/enabledisable/enabledisable/enabledisable.sh Timed Out (timeout in milliseconds: 3600000 from variable __TestTimeout, start: 3/12/2023 2:41:17 PM, end: 3/12/2023 3:41:17 PM)
Printing stacktrace from '/home/helixbot/dotnetbuild/dumps/crashdump_5912.dmp.crashreport.json'
Test Harness Exitcode is : -100
To run the test:
> set CORE_ROOT=/root/helix/work/correlation
> /root/helix/work/workitem/e/tracing/eventpipe/enabledisable/enabledisable/enabledisable.sh
Expected: True
Actual: False
Stack trace:
at tracing_eventpipe._enabledisable_enabledisable_enabledisable_._enabledisable_enabledisable_enabledisable_sh()
at System.RuntimeMethodHandle.InvokeMethod(Object target, Void** arguments, Signature sig, Boolean isConstructor)
at System.Reflection.MethodInvoker.Invoke(Object obj, IntPtr* args, BindingFlags invokeAttr)
coreclr linux arm Checked gcstress0x3 @ (Ubuntu.1804.Arm32.Open)[email protected]/dotnet-buildtools/prereqs:ubuntu-18.04-helix-arm32v7
- tracing/eventpipe/enabledisable/enabledisable/enabledisable.sh
coreclr linux x64 Checked gcstress0x3 @ Ubuntu.1804.Amd64.Open
- tracing/eventpipe/enabledisable/enabledisable/enabledisable.sh
coreclr linux arm64 Checked gcstress0x3 @ (Ubuntu.1804.Arm64.Open)[email protected]/dotnet-buildtools/prereqs:ubuntu-18.04-helix-arm64v8
- tracing/eventpipe/enabledisable/enabledisable/enabledisable.sh
coreclr windows x64 Checked gcstress0xc @ Windows.10.Amd64.Open
- baseservices/threading/regressions/2164/foreground-shutdown/foreground-shutdown.cmd
coreclr windows arm64 Checked gcstress0x3 @ Windows.11.Arm64.Open
- tracing\\eventpipe\\enabledisable\\enabledisable\\enabledisable.cmd
Error message:
cmdLine:/root/helix/work/workitem/e/tracing/eventpipe/enabledisable/enabledisable/enabledisable.sh Timed Out (timeout in milliseconds: 3600000 from variable __TestTimeout, start: 4/2/2023 4:19:28 PM, end: 4/2/2023 5:19:28 PM)
Return code: -100
Raw output file: /root/helix/work/workitem/uploads/Reports/tracing.eventpipe/enabledisable/enabledisable/enabledisable.output.txt
Raw output:
BEGIN EXECUTION
/root/helix/work/correlation/corerun -p System.Reflection.Metadata.MetadataUpdater.IsSupported=false enabledisable.dll ''
cmdLine:/root/helix/work/workitem/e/tracing/eventpipe/enabledisable/enabledisable/enabledisable.sh Timed Out (timeout in milliseconds: 3600000 from variable __TestTimeout, start: 4/2/2023 4:19:28 PM, end: 4/2/2023 5:19:28 PM)
Printing stacktrace from '/home/helixbot/dotnetbuild/dumps/crashdump_4621.dmp.crashreport.json'
Test Harness Exitcode is : -100
To run the test:
set CORE_ROOT=/root/helix/work/correlation
/root/helix/work/workitem/e/tracing/eventpipe/enabledisable/enabledisable/enabledisable.sh
Expected: True
Actual: False
Stack trace
at tracing_eventpipe._enabledisable_enabledisable_enabledisable_._enabledisable_enabledisable_enabledisable_sh()
at System.RuntimeMethodHandle.InvokeMethod(Object target, Void** arguments, Signature sig, Boolean isConstructor)
at System.Reflection.MethodInvoker.Invoke(Object obj, IntPtr* args, BindingFlags invokeAttr)
Activity
mikelle-rogers commentedon Mar 13, 2023
Failed in Run: runtime-coreclr gcstress0x3-gcstress0xc 20230312.1
Failed tests:
Error message:
Stack trace:
More failures
v-wenyuxu commentedon Apr 3, 2023
Failed again in: runtime-coreclr gcstress0x3-gcstress0xc 20230402.1
Failed test:
Error message:
More failures
JulieLeeMSFT commentedon Apr 7, 2023
This failure is making the pipeline red for more than a month. Can you please take a look? ping @davmason
davmason commentedon Apr 7, 2023
We can disable this test under GCStress entirely