Skip to content

Error handling is too brittle for Windows IpcStreamFactory/IPC PAL #41007

Description

@josalem

If a Connect Diagnostic Port doesn't explicitly call DisconnectNamedPipe before closing the handle, the error handling in the runtime will erroneously treat this as a generic error rather than a hangup. The if statement currently only marks ERROR_PIPE_NOT_CONNECTED as a hangup, but should also treat ERROR_PIPE_BROKEN as a hangup. The current error path also does not reset the connection, so the cache is still there on subsequent loops through IpcStreamFactory::GetNextAvailableStream which leaves us waiting on handles that no longer are attached to anything.

The fix is simple and twofold: reset connections on the error path & map ERROR_PIPE_BROKEN to the hangup state rather than error state. The PR is incoming.

CC @tommcdon @sywhang @noahfalk @jander-msft

Activity

  1. added this to the 5.0.0 milestone on Aug 19, 2020
  2. self-assigned this
    on Aug 19, 2020
  3. added
    untriaged
    on Aug 19, 2020
  4. josalem commented on Aug 19, 2020

    @josalem
    ContributorAuthor

    See dotnet/diagnostics#1420 (comment) for a description of the issue

  5. removed
    untriaged
    on Aug 19, 2020
  6. ghost locked as resolved and limited conversation to collaborators on Dec 7, 2020