Libs: (bug) TimeSpan day-based constructors silently wrap instead of throwing for out-of-range durations #134109
new TimeSpan(days, hours, minutes, seconds[, ms[, µs]]) accumulates into an unchecked Int64 microsecond total and only range-checks the already-wrapped sum, so large days values silently produce a tiny (or zero) TimeSpan instead of throwing ArgumentOutOfRangeException.
Minimal Repro
usingSystem;Console.WriteLine(newTimeSpan(213503983,0,0,0));// ~584,942 years requestedConsole.WriteLine(newTimeSpan(-213503983,0,0,0));Console.WriteLine(newTimeSpan(213503982,8,1,49,551,616));// sums to exactly 2^64 microsecondsConsole.WriteLine(newTimeSpan(213503983,0,0,0,0));Console.WriteLine(newTimeSpan(213503983,0,0,0,0,0));TimeSpan.FromDays(213503983,0,0,0);// correctly throwsnewTimeSpan(TimeSpan.MaxValue.Days+1,0,0,0);// correctly throws
Expected
All five constructor calls throw ArgumentOutOfRangeException, as documented and as TimeSpan.FromDays(int, int, int, int) already does for the same arguments. TimeSpanTests.Ctor_Int_Int_Int_Int_Int_Invalid asserts exactly this contract for MaxValue.Days + 1.
Actual
15:58:10.4483840 // new TimeSpan(213503983, 0, 0, 0)
-15:58:10.4483840
00:00:00 // a ~584,942-year duration becomes TimeSpan.Zero
15:58:10.4483840
15:58:10.4483840
ArgumentOutOfRangeException: TimeSpan overflowed because the duration is too long. // FromDays
ArgumentOutOfRangeException: TimeSpan overflowed because the duration is too long. // MaxValue.Days + 1
Reproduces identically on .NET 8, 9 and 10.0.7.
Notes
MicrosecondsPerDay is 86,400,000,000, so days only needs to exceed ~213,503,982 for days * MicrosecondsPerDay to wrap Int64 — well inside int and reachable from arithmetic on user input or config. The TimeSpan.Zero case is the dangerous one: a huge duration handed to a timeout/delay API becomes an immediate-fire value. Dates from c88b783bd9d (#94226), which switched the intermediate accumulator from milliseconds to microseconds; #98633 later fixed the same class of problem in the integer From* factories (using Int128) but left the constructors alone. Fix: accumulate in Int128 as FromDays(int,int,int,int) does, or range-check days before multiplying.
I’d like to work on this. I’ve reproduced the overflow path in the current implementation and have a fix that uses widened arithmetic before the range check, together with regression coverage for the affected constructors.
Activity
dotnet-policy-service commentedon Sep 16, 2026
Tagging subscribers to this area: @dotnet/area-system-datetime
See info in area-owners.md if you want to be subscribed.
Fix TimeSpan constructor overflow
asad24-dev commentedon Sep 16, 2026
I’d like to work on this. I’ve reproduced the overflow path in the current implementation and have a fix that uses widened arithmetic before the range check, together with regression coverage for the affected constructors.
Improve TimeSpan overflow coverage
Fix TimeSpan constructor overflow (#134113)
Fix TimeSpan constructor overflow (dotnet#134113)