SymbolReader doesn't allow UNC symbol server paths #674
Why do local paths need to be excluded at all? I have hundreds of local folders that are legitimate symbol stores (mostly along the lines of srv*D:\xperf\Bug12345_Repro.etl.NGENPDB)
There are more or less two variants of symbol lookup...
Old-fashioned, no-symsrv way:
PS C:\Program Files (x86)\Windows Kits\10\Debuggers\x64> .\symchk.exe C:\Windows\System32\combase.dll /v /s "C:\othersym"
[SYMCHK] Searching for symbols to C:\Windows\System32\combase.dll in path C:\othersym
DBGHELP: Symbol Search Path: C:\othersym
[SYMCHK] Using search path "C:\othersym"
DBGHELP: No header for C:\Windows\System32\combase.dll. Searching for image on disk
DBGHELP: C:\Windows\System32\combase.dll - OK
DBGHELP: C:\othersym\combase.pdb - file not found
DBGHELP: C:\othersym\dll\combase.pdb - file not found
DBGHELP: C:\othersym\symbols\dll\combase.pdb - file not found
The symsrv way:
PS C:\Program Files (x86)\Windows Kits\10\Debuggers\x64> .\symchk.exe C:\Windows\System32\combase.dll /v /s "srv*C:\othersym"
[SYMCHK] Searching for symbols to C:\Windows\System32\combase.dll in path srv*C:\othersym
DBGHELP: Symbol Search Path: srv*C:\othersym
[SYMCHK] Using search path "srv*C:\othersym"
DBGHELP: No header for C:\Windows\System32\combase.dll. Searching for image on disk
DBGHELP: C:\Windows\System32\combase.dll - OK
SYMSRV: BYINDEX: 0x1
C:\othersym
combase.pdb
28C4EF2E3A6DD5EA0CBCA4163A6505321
SYMSRV: UNC: C:\othersym\combase.pdb\28C4EF2E3A6DD5EA0CBCA4163A6505321\combase.pdb - path not found
SYMSRV: UNC: C:\othersym\combase.pdb\28C4EF2E3A6DD5EA0CBCA4163A6505321\combase.pd_ - path not found
SYMSRV: UNC: C:\othersym\combase.pdb\28C4EF2E3A6DD5EA0CBCA4163A6505321\file.ptr - path not found
SYMSRV: RESULT: 0x80070003
Because the NGENPDB folders include symbols in the format of {pdbFilename\{signature}{age}\{pdbFilename}, a srv*-less symbol path will result in failed symbol lookups.
Note that casual testing, e.g. .sympath C:\symbols will likely fail to reproduce this behavior - because dbghelp checks for a pingme.txt file in the root folder for drive & UNC paths, and automatically inserts a srv* star if it's present.
I have a fix (will merge it soon) for supporting UNC paths as "servers" with the {pdbFilename\{index}\{pdbFilename} directory structure. Hopefully that is enough for your scenarios. The sympath support in SOS isn't going to handle all the subtleties that symsrv/windbg can especially things like custom symbol server dlls (they wouldn't work for portable PDBs anyway). It is meant for setting up fairly simple symbol search paths for portable PDBs. Any failures will not affect windbg's symbol searching.
Activity
mikem8361 commentedon Dec 6, 2019
Looks like I should also check if !url.IsUnc.
The SymStore code has the same check in The HttpSymbolStore constructors. It will need the same change.
Zhentar commentedon Dec 6, 2019
Why do local paths need to be excluded at all? I have hundreds of local folders that are legitimate symbol stores (mostly along the lines of
srv*D:\xperf\Bug12345_Repro.etl.NGENPDB)mikem8361 commentedon Dec 6, 2019
The sympath parsing does support directories and UNC paths, but as far as I can tell from the docs directory paths are not prefixed with "srv*".
Should work. SRV* is for symbol servers and you can also specify a cache for the server like:
Zhentar commentedon Dec 9, 2019
There are more or less two variants of symbol lookup...
Because the NGENPDB folders include symbols in the format of
{pdbFilename\{signature}{age}\{pdbFilename}, asrv*-less symbol path will result in failed symbol lookups.Note that casual testing, e.g.
.sympath C:\symbolswill likely fail to reproduce this behavior - because dbghelp checks for apingme.txtfile in the root folder for drive & UNC paths, and automatically inserts asrv*star if it's present.There are also quite a few other potential subtleties to symsrv paths, detailed here: https://docs.microsoft.com/en-us/windows-hardware/drivers/debugger/advanced-symsrv-use . Things like
symsrv*symsrv.dll**\\network\symbol_cache*https://msdl.microsoft.com/download/symbolsare perfectly legal (and there could even be alternative symsrv implementations that take non-path input!)SymbolReader doesn't support UNC symbol paths. Issue: dotnet#674
mikem8361 commentedon Dec 11, 2019
I have a fix (will merge it soon) for supporting UNC paths as "servers" with the
{pdbFilename\{index}\{pdbFilename}directory structure. Hopefully that is enough for your scenarios. The sympath support in SOS isn't going to handle all the subtleties that symsrv/windbg can especially things like custom symbol server dlls (they wouldn't work for portable PDBs anyway). It is meant for setting up fairly simple symbol search paths for portable PDBs. Any failures will not affect windbg's symbol searching.SymbolReader doesn't support UNC symbol paths. Issue: dotnet#674
SymbolReader doesn't support UNC symbol paths. Issue: dotnet#674
SymbolReader doesn't support UNC symbol paths. Issue: dotnet#674
Fix various issues (#690)
mikem8361 commentedon Dec 15, 2019
PR #690
Merge latest master into release/stable (#993)