…eepchem#5194) is_hydrogen_bond indexed frag1 coordinates with the frag2 loop counter, returned after checking only the first candidate hydrogen, and compute_hbonds_in_range passed the angle cutoff positionally so it landed in the unused distance parameter. Donor-in-frag1 contacts were never found and the per-bin angle cutoff was always the default.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Closes #5194.
Whether
compute_hydrogen_bondsfound a valid bond depended on theorder fragments and hydrogens were passed.
frag1_xyz[i]indexed withthe frag2 loop counter, placing frag1 hydrogens at frag2 coordinates.
The hydrogen-candidate loop broke out after the first candidate
instead of examining all of them.
hbond_angle_cutofflanded in thedistance parameter positionally, so the caller's angle bound never
applied.
Indexing is corrected. Every candidate is visited and the cutoff
passes by keyword. The previously empty
test_compute_hydrogen_bondsnow covers all four orderings plus a bent geometry where a tight
cutoff rejects and a loose one accepts.