Skip to content

fix(automations): record failure reason on failed automation runs - #4343

Merged
tlgimenes merged 1 commit into
mainfrom
fix/automation-failure-reason
Jul 6, 2026
Merged

tlgimenes merged 1 commit into
mainfrom
fix/automation-failure-reason

Conversation

@tlgimenes

@tlgimenes tlgimenes commented Jul 6, 2026 •

Copy link
Copy Markdown
Contributor

Problem

Automation runs that fail — including the 5-minute timeout abort — were marked status = 'failed' with failure_reason and failure_kind left NULL. The UI then shows a reason-less "errored" with no explanation.

Found while investigating a real prod thread (thrd_J5cKVKyrKLyEHM-Dc3wT7, Deco org): an automation fire ran for exactly 5:00 and was aborted by AUTOMATIONS_RUN_TIMEOUT_MS mid-run (task 1 of a 17-task commerce-discovery workflow). The DBOS hostedHarnessWorkflow recorded SUCCESS (a timeout abort is a clean cancellation), but the thread showed a bare "failed" with no reason.

Root cause

  • AutomationsStorage.markRunFailed(taskId) (storage/automations.ts) set only status: 'failed' — never failure_reason/failure_kind (the columns exist and are used elsewhere).
  • fireAutomationWorkflow already computes the error message (runError) and even classifies permanent vs transient — but discarded it when calling markRunFailedStep(taskId).

Changes (small, contained)

  • markRunFailed(taskId, reason?, kind?) now persists failure_reason/failure_kind when provided. It only sets them when non-null, so it never clobbers an existing reason.
  • fireAutomationWorkflow passes the reason + a kind at all three failure sites:
    • build/setup failure → kind: "setup" (reason = built.reason)
    • permanent dispatch error → kind: "permanent" (reason = runError)
    • transient error → kind: "error" (reason = runError)
  • The opt-in run timeout now calls abortController.abort(new Error("Run exceeded its 5m time limit and was aborted")) instead of a bare abort(), so a timeout surfaces as a legible error that flows into failure_reason (and logs), rather than a generic abort.

Net effect: a timed-out or otherwise-failed automation now shows why it failed instead of a mystery error.

Testing

  • tsc --noEmit clean for the changed files; bun run fmt clean.
  • (oxlint wasn't runnable in my local shell this session — CI lint will cover it. Changes are plain server-side edits with no lint-sensitive patterns.)
  • No automated test added: the markRunFailed change is DB I/O (e2e tier per TESTING.md, not unit). The behavior is a straightforward column write; happy to add an e2e assertion on failure_reason if you'd like.

Notes / possible follow-ups

  • This fixes the automation failure path (where the reason is dropped today). Interactive (non-automation) hosted runs don't set a timeout, so they're unaffected.
  • A separate, larger option we discussed — making the 5-minute cap configurable per-automation — is intentionally not in this PR.

🤖 Generated with Claude Code


Summary by cubic

Record and surface failure_reason and failure_kind for failed automation runs, including timeout aborts, so the UI shows a clear failure reason instead of a blank "errored".

  • Bug Fixes
    • markRunFailed(taskId, reason?, kind?) now persists failure_reason/failure_kind when provided (never overwrites with null).
    • fireAutomationWorkflow passes reason/kind for all failure paths: setup ("setup"), permanent ("permanent"), transient ("error").
    • Hosted harness run-timeout aborts with a human-friendly error (e.g., "Run exceeded its 5m time limit and was aborted") so timeouts populate failure_reason.

Written for commit 616c4dd. Summary will update on new commits.

Review in cubic

@tlgimenes
tlgimenes force-pushed the fix/automation-failure-reason branch 2 times, most recently from e83a861 to 87a482d Compare July 6, 2026 21:23
Automation runs that fail (including the 5-minute timeout abort) were marked
`status='failed'` with `failure_reason`/`failure_kind` left NULL, so the UI
showed a reason-less "errored" with no explanation.

Root cause: `AutomationsStorage.markRunFailed(taskId)` set only the status, and
`fireAutomationWorkflow` computed the error message (`runError`) but discarded
it when calling `markRunFailedStep`.

Changes:
- `markRunFailed(taskId, reason?, kind?)` now persists `failure_reason` /
  `failure_kind` when provided (never clobbers an existing reason with null).
- `fireAutomationWorkflow` passes the reason + a kind at all three failure
  sites: setup (`"setup"`), permanent dispatch error (`"permanent"`), and
  transient error (`"error"`).
- The opt-in run-timeout now aborts with a descriptive reason
  ("Run exceeded its 5m time limit and was aborted") instead of a bare abort,
  so a timeout surfaces as a legible error that flows into failure_reason.

Co-Authored-By: Claude Opus 4.8 (1M context) <[email protected]>
@tlgimenes
tlgimenes force-pushed the fix/automation-failure-reason branch from 87a482d to 616c4dd Compare July 6, 2026 21:27
@tlgimenes
tlgimenes merged commit 7e2321e into main Jul 6, 2026
14 checks passed
@tlgimenes
tlgimenes deleted the fix/automation-failure-reason branch July 6, 2026 21:47
decocms Bot pushed a commit that referenced this pull request Jul 6, 2026
PR: #4343 fix(automations): record failure reason on failed automation runs
Bump type: patch

- decocms (apps/mesh/package.json): 3.100.0 -> 3.100.1

Deploy-Scope: server
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment