engine: wasm backend refuses conveyor inflows with a spread placement #946
The wasm backend refuses a conveyor inflow whose isee:spreadflow placement is even, dest, dist or source.
It only supports the default beginning, where the whole inflow lands on the entry slat.
The bytecode VM simulates all five, so these models run on the VM but fail if a caller asks for the wasm engine (there is no automatic fallback).
Example
test/conveyors/sir_social_distancing_mixnot.stmx (a vendored Stella model) has a dist inflow.
It cannot reach the wasm backend yet anyway: its conveyors live in a sub-model, which no backend supports (#941).
Why it matters
Only wasm users of spread-inflow models are affected, and the refusal is a clear error, not a wrong number.
No model in the repo can hit it until #941 is fixed.
Low priority.
Fix
Port the VM's per-slat placement to the wasm belt pass:
a per-belt scratch buffer of per-slat shares that grows with the belt and is reset with it;
the leak-window bookkeeping at insertion done slat by slat, transcribed from ConveyorState::insert (today it is folded into a single-slat shortcut that is only exact for beginning);
for dist, a weight vector recomputed each step, since a sampled transit time changes the belt length;
for source, a copy of the upstream belt's per-slat leak amounts taken before the upstream belt admits its own inflow, kept until the downstream belt inserts.
source is the hardest; even, dest and dist could land first.