conveyor-engine: run_coupled_passes rebuilds the compile-time-constant coupling table every Euler step #878
Found by branch review of conveyor-engine before merge (the in-flight XMILE conveyor+queue implementation; specs docs/design/conveyors.md + docs/design/queues.md). Filed from a review report that exceeded its 15-finding cap.
Summary
run_coupled_passes rebuilds the compile-time-constant coupling table (a coupling_for_conveyor Vec, a queue_is_coupled Vec, and an any flag) from the immutable queue plans on every Euler step, before the !any fast path usually discards it. A no-coupling conveyor/queue model heap-allocates and re-derives "no coupling" each dt, even though apply_couplings fixed the answer once at build time.
Failure scenario / cost
A 10,000-step Euler run of a plain one-conveyor model (queue_plans empty) executes run_coupled_passes (vm.rs:885) every step; queue_compile.rs:1132 allocates and fills vec![None; conv_plans.len()] (~10,000 pointless heap allocations), the queue-outflow scan at :1135 runs zero iterations, any stays false, and :1158 discards the table via the fast path. A model with a conveyor plus an independent uncoupled queue pays both allocations (:1132 and :1133) plus a full outflow scan (:1135-1154) each step, all still discarded. Per-step cost scales with (conveyors + queues) though the coupling never changes.
Evidence
called every step, plans borrowed immutably: crate::queue_compile::run_coupled_passes(&self.conveyor_plans, &mut self.conveyors, &self.queue_plans, ...) (src/simlin-engine/src/vm.rs:885-894), inside Method::Euler => loop { (vm.rs:831)
rebuilt each step: let mut coupling_for_conveyor: Vec<Option<CoupledServe>> = vec![None; conv_plans.len()]; (queue_compile.rs:1132), let mut queue_is_coupled = vec![false; queue_plans.len()]; (:1133), let mut any = false; (:1134), the scan (:1135), then if !any { fast path (:1157-1159)
coupling fixed once at build: op.kind = QueueOutflowKind::Coupled { inside apply_couplings (queue_compile.rs:1066), called at :898 within build_compiled
plans carry Coupled through clone/reset: if let Some(ref plans) = state.queue_plans { new_vm.set_queue_plans(plans.clone()); } (src/libsimlin/src/simulation.rs:420-424)
Suggested direction
Materialize the coupling table once in apply_couplings (or at plan-resolution time) and precompute the no-coupling bool, so the per-step pass reads it instead of rebuilding it.
Activity