engine: a conveyor leak fraction given as a graphical function is ignored #865
A conveyor leak flow whose fraction is a graphical function (the flow has a <gf> and its <eqn> is the lookup input) simulates with the wrong fraction and no warning.
Conveyor expansion copies the flow's equation into a hidden fraction variable but not its graphical function, so the leak fraction becomes the raw lookup input instead of the table's output.
A per-element <gf> on an arrayed leak flow is carried over; only a whole-variable <gf> is lost.
Example
A leak flow with <leak/>, <eqn>TIME</eqn>, and a <gf> mapping 0..10 to 0..0.1: at TIME = 5 the leak fraction used is 5 (clamped to 1 on a linear-leak conveyor, so the whole zone drains), not the table's 0.05.
Why it matters
Silent wrong numbers.
Stella lets any flow be a graphical function, so this is a plausible way to write a time- or state-dependent leak fraction, but we have not seen it in a real model.
Fix
In leak_fraction_equation's flow-equation case, copy the flow's gf onto the synthesized fraction aux; this is a few lines plus a test.
When an explicit <leak>expr</leak> fraction is present the flow's <gf> does not apply to it; reject that combination rather than guess.
Cross-reference: #944 tracks the case item 2 above explicitly carves out -- a same-step direct read of a conveyor-driven leak flow. That rule (not just the PREVIOUS() variant) blocks the checked-in Stella fixture test/conveyors/covid19_severity.stmx, whose death rate aux sums four conveyor leak flows. A design that permits the direct read subsumes item 2, so the two are best resolved together.
changed the title [-]Conveyor engine: deferred edge-case limitations (GF leak fraction, PREVIOUS(driven_flow), JSON serialization)[/-][+]engine: a conveyor leak fraction given as a graphical function is ignored[/+]on Oct 12, 2026
Activity
bpowers commentedon Jul 11, 2026
Cross-reference: #944 tracks the case item 2 above explicitly carves out -- a same-step direct read of a conveyor-driven leak flow. That rule (not just the
PREVIOUS()variant) blocks the checked-in Stella fixturetest/conveyors/covid19_severity.stmx, whosedeath rateaux sums four conveyor leak flows. A design that permits the direct read subsumes item 2, so the two are best resolved together.[-]Conveyor engine: deferred edge-case limitations (GF leak fraction, PREVIOUS(driven_flow), JSON serialization)[/-][+]engine: a conveyor leak fraction given as a graphical function is ignored[/+]