Repository navigation
Description
Description
After four root-cause fixes on branch fix-clearn-unit-errors reduced the C-LEARN unit-diagnostic flood from 481 spurious diagnostics to ~14 (fixes: Context self-alias registration, units_infer time-unit alias resolution, units_check tolerating unknown dependency units, and skipping macro-marked models during unit checking), C-LEARN still produces ~14 unit warnings that genuine Vensim does not flag as mismatches. These break down as:
- 6-7
computed units 'gtonsc/degreesc/yr' don't match specified unitson permafrost/clathrate methane-flux variables (flux_c_from_permafrost_release,ch4_emissions_from_permafrost_and_clathrate) -- a temperature-sensitivity-coefficient unit that does not fully cancel. - 6
expected left and right argument units to match, but 'dmnl' and '1/ppm' don'ton thephvariable (a log/concentration formula). - 1
IF branches have different units: then '1/gtonsco2', else '1/yr'onglobal_annual_rate_of_co2eq_2050_to_2100. - 1 umbrella main-model
unit inference [...]: unit_mismatchwarning (which underlying conflict it reports is nondeterministic -- see engine: World3 unit-alias test passes or fails depending on test order #474 for the order-dependence root cause).
The open question
It is not yet established whether these are:
- Simlin being legitimately stricter than Vensim -- e.g. Vensim may not check IF-branch unit consistency, or may not require the argument of a
LOG/concentration formula to be dimensionless. If so, we may want to relax those specific checks for Vensim parity (an IF-branch-units check and a log-argument-dimensionlessness check are the two candidate relaxations). - Genuine dimensional inconsistencies in the C-LEARN model that Vensim happens to tolerate silently. If so, the diagnostics are correct and the resolution is to document them as known model-authoring imprecision (not an engine change).
Resolving this requires per-variable investigation of the C-LEARN equations against Vensim's actual unit-checking semantics for each of the three distinct message classes (coefficient non-cancellation, log-argument dimensionlessness, IF-branch consistency).
Why it matters
- Unit checking is meant to be a verification safety net; residual noise on a flagship real-world model (C-LEARN) erodes trust in it and can mask genuine errors.
- If Simlin is over-strict relative to Vensim, every imported Vensim model with these idioms inherits spurious diagnostics.
- If these are genuine model errors, surfacing them is correct behavior and the work is documentation, not code.
Components affected
src/simlin-engine/src/units_check.rs-- the IF-branch consistency check and the log/binary-operator argument-units checkssrc/simlin-engine/src/units_infer.rs-- coefficient unit cancellation during inference
Reproduce
cargo test -p simlin-engine --test clearn_unit_errors -- --ignored --nocapture dump_clearn_unit_diagnostics
Context
Discovered while fixing the C-LEARN unit-error flood on branch fix-clearn-unit-errors (481 -> 14 diagnostics via four root-cause fixes). These ~14 are explicitly out of scope for that branch -- they require a Vensim-parity semantics decision per message class, not a mechanical fix. Distinct from #454 (resource_unit/resource_units alias), #455 (year-vs-implicit-time stock unification), #456 (duplicate_unit per stdlib instance), #457 (stdlib module output units not propagated), and #474 (the order-dependence that makes the umbrella diagnostic nondeterministic). Related: #35 (general unit-checking tracker).
Activity
engine: clear C-LEARN unit-error flood (481 -> 14) (#615)