Skip to content

GUI allows multiple links into Loop Start's input port, failing only at run time #7155

Closed

Description

@aglinxinyuan

What happened?

The GUI lets you connect two upstream operators into a Loop Start's single input port. Nothing in the editor flags it — no link is refused, validation stays green — and the workflow only fails when you run it:

java.lang.IllegalArgumentException: requirement failed:
Loop Start input port GlobalPortIdentity(
    PhysicalOpIdentity(OperatorIdentity(LoopStart-operator-...),main),
    PortIdentity(0,false), true)
  expected exactly one reader URI, got 2
    at WorkflowExecutionManager.loopStartStateUris(WorkflowExecutionManager.scala:69)
    at StartWorkflowHandler.startWorkflow(StartWorkflowHandler.scala:45)

Loop Start being single-input is intended — the scheduler resolves that loop's bookkeeping URIs from its input port's single reader, so fan-in belongs in a Union before the loop, as discussed in #6966. The bug is that the restriction is invisible until run time.

(This does not apply to Loop End, which supports fan-in — a loop body may branch and converge on it. That side is tracked in #7246.)

How to reproduce?

  1. Drop a Loop Start and two source operators on the canvas.
  2. Connect both sources to the Loop Start's input port — both links are accepted.
  3. Run the workflow → it fails at StartWorkflow with the error above.

Version/Branch

1.3.0-incubating-SNAPSHOT (main)

Root cause

InputPort already carries a disallowMultiLinks flag, and the frontend honors it in two independent places:

Guard Where Reads the flag from
Editor refuses to draw a second link into the port workflow-editor.component.ts operator metadata (dynamic schema)
Validation requires exactly one input on the port validation-workflow.service.ts the saved operator predicate

Loop Start never sets it — LoopOpDesc.operatorInfo declares a plain InputPort().

Expected behavior

before after
Drawing a 2nd link into Loop Start's input port allowed refused by the editor
Programmatically built plan fails at StartWorkflow unchanged — the scheduler require stays as a backstop
Loop End with 2+ inbound links — still allowed (see #7246)

Activity

  1. added theissue type on Jul 31, 2026
  2. changed the title [-]GUI allows multiple links into a loop operator's input port, failing only at run time[/-] [+]GUI allows multiple links into Loop Start's input port, failing only at run time[/+] on Aug 2, 2026
  3. added a commit that references this issue on Aug 2, 2026