Reading the two binary readers side by side, the load/store alignment immediate gets widened differently:

binary-reader-ir.cc:      1ull << alignment_log2
binary-reader-interp.cc:  1 << alignment_log2

The interp form shifts a signed int. CheckAlignment only rejects alignment_log2 >= 32, so a load or store in an untrusted module can carry alignment_log2 == 31, and 1 << 31 on int is signed overflow. Switching the literal to 1u makes the shift unsigned; the returned value is unchanged.

@sbc100
sbc100 merged commit 2d84a99 into WebAssembly:main Jun 5, 2026