Skip to content

Status bar: stale final click count, no stop reason, safety stops shown in neutral color #53

Closed

Description

@TMHSDigital

Summary

The status bar ends a run with stale or ambiguous information:

  • Final click count is stale. The 1 s status timer stops as soon as is_running goes false, and _paint_stopped() never refreshes the counters. The final count can lag the real one by up to a second of clicks.
  • No stop reason. Hitting the max-clicks limit, auto-stop timeout, and user Stop all show "Stopped".
  • Safety stops are colored grey. _state_color() keys on words like "safety" or "emergency", but the actual reasons are "failsafe" and "Runaway guard: exceeded 50 clicks/sec", so they get the neutral color.
  • The runtime placeholder Runtime: 0:00:00 doesn't match the live format 00:00:00.

Evidence

  • autoclicker/gui/main_window.py:150-156 (_paint_stopped), :371-375 (_update_status_loop).
  • autoclicker/gui/sections/status.py:17-25 (_state_color keyword matching), :50.
  • Reason strings in core/click_engine.py:322-324, :337.

Suggested approach

Done when

Final counts are exact, every stop reason is distinguishable, and safety stops render in the error color (GUI unit tests).

Activity

  1. added
    bug
    priority: low
    ux
    on Oct 4, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    bugpriority: lowux

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions