Skip to content

Use a monotonic clock for auto-stop, runaway guard, and runtime #52

Closed

Description

@TMHSDigital

Summary

The engine measures auto-stop, the runaway-CPS window, and runtime with time.time() (the wall clock). An NTP sync, a manual clock change, or a DST/timezone change during a session can:

  • trigger auto-stop early (clock jumps forward) or never (clock jumps back),
  • distort the 1-second runaway window (false trips or a blind spot),
  • show a negative or jumping runtime.

Evidence

autoclicker/core/click_engine.py:142 (start_time), :192, :360-363 (runaway window), :392 (auto-stop), :493 (click timestamps), :544 (runtime).

Suggested approach

Use time.monotonic() for all durations and intervals. Keep time.time() only where a wall-clock timestamp is displayed or logged. Update tests that patch time.time.

Done when

No elapsed-time logic depends on time.time(), and a test that patches monotonic verifies auto-stop is unaffected by a wall-clock jump.

Activity

  1. added
    bug
    priority: low
    safety
    on Oct 4, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment