You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Safety E-STOP fires on pure noise in 54% of 1-second runs; statistic is not an e-process #2
RtFusionKernel.stepImu documents an "anytime-valid e-process" with warn_e_threshold = 20 // alpha <= 0.05 and estop_e_threshold = 1000 // alpha <= 0.001. Neither bound holds.
Measured (Zig 0.16.0 ReleaseFast, M2 Max, c1ead21). Input is i.i.d. accel_z = 9.81 + N(0, 0.05²), with no anomaly; 2,000 runs of 1,000 steps (1 s at 1 kHz), seed 17:
claimed
measured
P(WARN at any time)
≤ 0.05
0.998
P(E_STOP)
≤ 0.001
0.542
Why:
The increment 3·|z| − 4.5 uses |z| in a one-sided Gaussian likelihood ratio. Under H0, E[exp(3|z| − 4.5)] = 2·Φ(3) ≈ 2.0, not ≤ 1, so the running product is not a supermartingale.
log_e = max(0, log_e + lr) is a CUSUM recursion. Clamping at 0 also breaks Ville's inequality. CUSUM is a fine change detector, but its threshold sets an average run length, not an error probability.
Fix: either (a) use a valid two-sided mixture e-process without clamping, and calibrate it, or (b) call it CUSUM, and pick thresholds from a measured in-control run length. Then add the false-alarm simulation as a test.
Activity