Skip to content
SMC17Public

About

Physical-intelligence substrate for HVAC + cold-chain in Zig. AGPL-3.0.

Topics

Resources

Code of conduct

Contributing

Security policy

Stars

1 star

Watchers

0 watching

Forks

carreir

Status · Roadmap · Contributing · Issues · Public roadmap

Physical-intelligence substrate for HVAC + cold-chain in Zig. HMAC-SHA256 chained cold-chain log with TLA+ formal spec model-checked by CI.

CI License: AGPL-3.0 Zig: 0.16 Tests: 54/54 Formal

A Zig physical-intelligence substrate for HVAC and cold-chain research. Deterministic kernels for psychrometric calculations, refrigerant saturation tables, and tamper-evident cold-chain logging.

Pre-1.0. Zig itself is on 0.16; no production deployment exists. The substrate is genuinely usable for ASHRAE psychrometric calculations, NIST-style refrigerant lookups, and HMAC-chained cold-chain logging today — but it is not a replacement for EnergyPlus, TRNSYS, NIST REFPROP, or a certified compliance system. See STATUS.md for proof levels per module.

What ships

  • psychrometric/ — ASHRAE 2021 Ch.1 moist-air primitives (22 unit tests)
  • refrigerant/ — NIST-published saturation P-T for R-134a / R-410A / R-32 / R-1234yf / R-744 (21 unit tests)
  • coldchain/ — HMAC-SHA256 append-only reefer log with TLA+ formal spec model-checked in CI (10 unit tests + 200-500 trial property tests)
  • chiller/ — comptime safety invariants for vapor-compression cycles (1 unit test)

What does NOT ship yet

  • Not cross-validated against EnergyPlus / TRNSYS / OpenStudio
  • Not differential-tested against NIST REFPROP as a library
  • No production deployment, no soak time, no incident history
  • No FDA/HACCP/EU-GDP certification (the log is compatible-shaped, not certified)
  • No BMS/SCADA gateway, no service surface

Architecture

flowchart LR
    A[Physical system] --> B[psychrometric<br/>ASHRAE moist-air]
    A --> C[refrigerant<br/>NIST P-T tables]
    A --> D[chiller<br/>vapor-compression]
    B --> E[coldchain<br/>HMAC-SHA256 audit log]
    C --> E
    D --> E
    E --> F[TLA+ spec<br/>model-checked]

    style E fill:#fce7f3,stroke:#db2777
    style F fill:#dcfce7,stroke:#16a34a
Loading

What it is

Three composable hulls under src/:

Hull Purpose Reference Proof level
psychrometric/ Moist-air primitives at standard pressure — saturation pressure, humidity ratio, enthalpy, dewpoint ASHRAE Handbook — Fundamentals (2021), Ch.1 unit-tested (22 cases)
refrigerant/ Saturation P-T tables + lookup for R-134a / R-410A / R-32 / R-1234yf / R-744 NIST Webbook + REFPROP-published values unit-tested (21 cases)
coldchain/ HMAC-SHA256 append-only reefer log with tamper detection + replay TLA+ formal spec (src/coldchain/Coldchain.tla) model-checked in CI audit-logged + unit-tested (10 cases) + model-checked
chiller/ Comptime safety invariants for vapor-compression chiller cycles (surge + slugging) First-principles thermodynamics unit-tested (1 case)

current_test_count: 54

Tests: 54/54 pass on Zig 0.16 / Linux x86_64 (zig build test --summary all). A drift-check workflow fails CI if the declared count and the actual count diverge.

A TLA+ formal specification of the cold-chain log (src/coldchain/Coldchain.tla) is model-checked on every push touching the spec. Three invariants are pinned: WriterLogIsAlwaysValid, TamperDetection, ReorderingDetected.

What it is not — honest non-claims

  • Not cross-validated against EnergyPlus / TRNSYS / OpenStudio. Psychrometric values are pinned to ASHRAE 2021 Ch.1 textbook examples; refrigerant values to NIST-published saturation points. Not yet differential-tested against a full HVAC simulator.
  • Not cross-checked against NIST REFPROP as a library — only against published reference points.
  • No production deployment. Zero real-traffic operation; zero soak time; zero production-incident history.
  • No certified regulatory compliance. The cold-chain log is shaped to be compatible with FDA 21 CFR Part 11, HACCP, and EU GDP audit trails, but compatibility is not certification.
  • No real building-management-system (BMS) integration. This is a set of in-process Zig libraries with a small CLI shell — not a service, not a gateway, not a SCADA adapter.

Quickstart

Requires Zig 0.16.0.

zig build test --summary all   # 54/54 pass

# CLI examples:
zig build run -- psychro 30 20                       # moist-air state for T_db=30°C, T_wb=20°C
zig build run -- refrigerant R-410A T=5              # saturation pressure of R-410A at 5°C
zig build run -- refrigerant R-134a P=400            # saturation temperature of R-134a at 400 kPa
zig build run -- coldchain replay /path/to/log.ccl   # verify HMAC chain on a reefer log

Cold-chain log — design summary

src/coldchain/log.zig (489 LOC) is the most-developed primitive.

Each on-disk entry is fixed-width 88 bytes:

timestamp_us   u64 LE    8
temperature_c  f32 LE    4
humidity       f32 LE    4
accel_x_mg     i16 LE    2
accel_y_mg     i16 LE    2
accel_z_mg     i16 LE    2
reserved       [2]u8     2
prior_hmac     [32]u8   32
hmac           [32]u8   32
                        88

The HMAC over each entry is HMAC-SHA256(key, prior_hmac || payload). Coupling each signature to the entire prefix means removing, reordering, or inserting any entry breaks the chain.

Threat model: an adversary can modify any byte of the stored log but does not have the HMAC key. verifyChain and replay reject single-bit tampering, entry swaps, deletions, and insertions.

Property-based tests (200–500 randomised trials per property) pin:

  • Random N-entry chain (N in [1, 100]) always appends and verifies.
  • Any single-bit flip in any byte is detected.
  • appendOne(key, prior_hmac, sample) is deterministic.
  • Verification with the wrong key always rejects.

The same invariants are encoded as a TLA+ specification (src/coldchain/Coldchain.tla) and model-checked by CI on every push that touches the spec.

Engineering posture

  • Zig 0.16 first; deterministic kernels.
  • AGPL-3.0 (integrators wrap for commercial; the substrate stays sovereign).
  • First-principles thermodynamics — no vendor SCADA coupling.
  • Pre-1.0 versioning; v1.0 only when both (a) Zig itself hits 1.0 and (b) a real production deployment exists.

Non-claims

  • Not a substitute for EnergyPlus / TRNSYS / OpenStudio / NIST REFPROP as a library.
  • Not a certified compliance system.
  • Not a SCADA adapter or BMS gateway.
  • The v1.0.0 git tag predates the Zig-1.0 + production-deployment gate; treat as pre-1.0 substrate per STATUS.md.

License

AGPL-3.0. See LICENSE.

Contributing

See CONTRIBUTING.md. Security disclosure: SECURITY.md. Project state and per-module proof levels: STATUS.md.

About

Physical-intelligence substrate for HVAC + cold-chain in Zig. AGPL-3.0.

Topics

Resources

Code of conduct

Contributing

Security policy

Stars

1 star

Watchers

0 watching

Forks

Releases

Packages

Used by

Contributors

Languages