VRF power in heat recovery using ThermostatOffsetPriority is 0 when coils are active #6485
Copy link
Copy link
Closed
Labels
PriorityHighThis defect or feature has been declared high priorityThis defect or feature has been declared high priority
Milestone
Description
Issue overview
Testing of the VariableRefrigerantFlow_5Zone example file and changing the master thermostat priority control type to ThermostatOffsetPriority shows that power sometimes goes to 0 when the coils are actively cooling or heating. The figure below exemplifies the problem.
AirConditioner:VariableRefrigerantFlow,
ThermostatOffsetPriority, !- Master Thermostat Priority Control Type