Issue overview
Problems noted after merge of #6248.
- 5ZoneAirCooledWithDOASAirLoop - OA table output shows zero mechanical ventilation - that's wrong.
- Unit tests
- DOATToUnitVentilator node connection warnings DOATToUnitVentilator node connection errors #6273
- Deal with furnaces searching for any ADU/DirectAir to find out the ZoneSequenceCoolingNum etc. - happens in Furnaces and HVACMultiSpeedHeatPump
- Review whether optimum start avail managers really works with multiple airloops in the sames zone - if more than one is opt start then it may be goofy - so, as it stands if any airloop serving a given zone goes into optimal start, the thermostat setting will changes for all equipment serving that zone. That's true even with one airloop and other zone equipment.
- Optimal start could be refactored to loop over the zones on the airloop instead of all zones for every decision
- Sort out NoHeatToReturnAir node by node instead of zone by zone
- Sort out zone loads in SystemReports::ReportSystemEnergyUse
- Sort out unbalanced exhaust warnings - currently by zone, not by airloop in ZoneEquipmentManager::SimZoneEquipment
- Sort out peak system load in OutputReportTabular::WriteComponentLoadSummaryTables
Details
Some additional details for this issue (if relevant):
- Platform (Operating system, version)
- Version of EnergyPlus (if using an intermediate build, include SHA)
- Unmethours link or helpdesk ticket number
Checklist
Add to this list or remove from it as applicable. This is a simple templated set of guidelines.
- Defect file added (list location of defect file here)
- Ticket added to Pivotal for defect (development team task)
- Pull request created (the pull request will have additional tasks related to reviewing changes that fix this defect)