Skip to content

ADEP-1765 Add the search.quant_fragment_isotopes setting - #978

Draft
GeorgWa wants to merge 1 commit into
adep-1765/1-elution-groups-to-rustfrom
adep-1765/2-quant-fragment-isotopes
Draft

GeorgWa wants to merge 1 commit into
adep-1765/1-elution-groups-to-rustfrom
adep-1765/2-quant-fragment-isotopes

Conversation

@GeorgWa

@GeorgWa GeorgWa commented Nov 27, 2026

Copy link
Copy Markdown
Collaborator

Part of ADEP-1765. Stacked on "Pass the elution groups of the spectral library to the Rust backend". Needs the alphadia-search-rs release with the fragment_isotopes quantification parameter.

  • New setting search.quant_fragment_isotopes, default False.
  • When it is on, the final quantification of the main search adds the M+1 XIC of each isotope-eligible fragment. Calibration, fragment competition and the requantification of the transfer step use the monoisotopic XICs.
  • ProteoBench: ratio error 0.1141 against 0.1197 on main, CV 0.088 against 0.095. We can set the default to True after the release.

🤖 Generated with Claude Code