Skip to content

pygmt.x2sys_init: Initialize a new x2sys track database #4570

Closed

Description

@seisman

This issue serves as the central place for discussing and tracking the implementation of the pygmt.x2sys_init function in PyGMT. The issue will be closed when the initial implementation is complete. Progress is tracked at PyGMT: Wrapping GMT modules.

Documentation

GMT Option Flags and Modifiers

☑️: Implemented; ⬜: To be implemented/discussed; Strikethrough: Won't implement.

  • ☑️ -D (fmtfile): Format definition file prefix for this data type; several built-in formats are provided (e.g., "mgd77", "xyz", "geo").
  • ☑️ -E (suffix): File extension (suffix) for the track data files.
  • ☑️ -F (force): Force a re-initialization of an existing TAG, overwriting the previous settings.
  • ☑️ -G (discontinuity): d|g. Select geographic coordinates and the longitude discontinuity convention (d for dateline, g for Greenwich).
  • ☑️ -I (spacing): dx[/dy]. Grid spacing for the track bin-index database.
  • ☑️ -N (units): d|s unit. Set the distance and speed units.
  • ☑️ -R (region): The region covered by the track data.
  • ☑️ -V (verbose): Verbosity level.
  • ☑️ -W (gap): t|d gap. Maximum time or distance gap between consecutive data points before a data gap is declared.
  • ☑️ -j (distcalc): Distance calculation mode (great circle, rhumb, Cartesian).
  • --PAR=value: Use pygmt.config instead.

Notes on Input Formats

  • tag (positional): The unique name for this x2sys TAG; all subsequent x2sys_cross calls reference this TAG.
  • x2sys_init does not take a data table as input; it creates configuration files in the directory pointed to by the X2SYS_HOME environment variable.
  • The X2SYS_HOME environment variable must be set to a writable directory before calling x2sys_init; otherwise GMT will raise an error.
  • Commonly used built-in fmtfile prefixes include "mgd77" (ASCII MGD77 marine geophysical data), "mgd77+" (enhanced MGD77+ netCDF), "xyz" (plain ASCII x,y,z), and "geo" (lon,lat).

Linked Pull Requests

  • Initial feature implementation – Wrap x2sys_init and x2sys_cross #546
  • Add a gallery or tutorial example (e.g., setting up an MGD77 TAG and running a crossover analysis with pygmt.x2sys_cross)

Related Issues and Discussions

  • pygmt.x2sys_init is always called first in an x2sys workflow; it must be run once to create the TAG before any pygmt.x2sys_cross calls.
  • All options currently appear to be implemented; this issue primarily tracks gallery examples and future maintenance tasks.
  • The force=True option is useful in automated testing or batch workflows where the TAG directory may already exist from a previous run.