PS_CONVERT has no effect when using Figure.show/Figure.savefig/Figure.psconvert #4256
Comma-separated list of optional module arguments that we should supply when psconvert is called implicitly under modern mode [A]. Ignored when psconvert is called on the command line explicitly. The option arguments must be listed without their leading option hyphen.
In PyGMT, Figure.show/Figure.savefig calls psconvert internally, so this option has no effect, which is expected according to the GMT documentation. As a workaround, we can explicitely add these options when calling Figure.show/Figure.savefig, but it's a little tedious.
Possible solutions are:
Document that PS_CONVERT is ignored in PyGMT.
In Figure.psconvert, parse the values of PS_CONVERT and append them to the argument list when calling psconvert.
Thinking about if there is a more Pythonic and elegant way to implement the same feature.
Solution 2 is not that hard to implement, but need time to think about solution 3.
After comparing Solutions 1 and 2, I prefer Solution 1.
The argument of PS_CONVERT (e.g., pygmt.config(PS_CONVERT="C-I/home/xxx/.gmt,E300") is not readable and not Pythonic. Users have to read through the GMT documentation to understand its meaning. It also changes the global configuration, which may have side-effect.
Instead of setting PS_CONVERT, user can set parameters when calling Figure.savefig/Figure.show, which is more readable and Pythonic:
Using gs_option (i.e. -C in psconvert) sounds reasonable. Maybe we can also remove or comment out PS_CONVERT from the autocomplete at so that people don't use it accidentally?
Raise a warning if pygmt.config(PS_CONVERT=...) is used.
Remove PS_CONVERT from autocomplete
Or is there a way still to make the PS_CONVERT config work if used globally?
In GMT CLI, PS_CONVERT is only used when calling gmt end. To make it work in PyGMT, we have to parse the value of PS_CONVERT and pass the CLI options psconvert when calling Figure.savefig/Figure.show. See the initial version in PR #4342
In GMT CLI, PS_CONVERT is only used when calling gmt end. To make it work in PyGMT, we have to parse the value of PS_CONVERT and pass the CLI options psconvert when calling Figure.savefig/Figure.show. See the initial version in PR #4342
This chunk of code is a little trickier to understand/maintain. So would lean towards just raising a warning when PS_CONVERT is used as you suggested ^.
Activity
seisman commentedon Jan 12, 2026
Thanks @Chuan1937 for tackling this in PR #4342.
After comparing Solutions 1 and 2, I prefer Solution 1.
The argument of
PS_CONVERT(e.g.,pygmt.config(PS_CONVERT="C-I/home/xxx/.gmt,E300")is not readable and not Pythonic. Users have to read through the GMT documentation to understand its meaning. It also changes the global configuration, which may have side-effect.Instead of setting
PS_CONVERT, user can set parameters when callingFigure.savefig/Figure.show, which is more readable and Pythonic:If the same parameters need to be reused, it's easy to define a dict and pass it to
Figure.savefig/Figure.showwhen needed. E.g.,seisman commentedon Jan 13, 2026
@GenericMappingTools/pygmt-maintainers Any comments?
weiji14 commentedon Jan 13, 2026
Using
gs_option(i.e.-Cin psconvert) sounds reasonable. Maybe we can also remove or comment outPS_CONVERTfrom the autocomplete atpygmt/pygmt/src/config.py
Line 138 in b1d4bd7
so that people don't use it accidentally? Or is there a way still to make the
PS_CONVERTconfig work if used globally?seisman commentedon Jan 13, 2026
With Solution 1, I think we should do:
PS_CONVERTis not supported in thepygmt.configdocumentation [Already done in Add a note/warning that PS_CONVERT is not supported #4342]pygmt.config(PS_CONVERT=...)is used.PS_CONVERTfrom autocompleteIn GMT CLI,
PS_CONVERTis only used when callinggmt end. To make it work in PyGMT, we have to parse the value ofPS_CONVERTand pass the CLI optionspsconvertwhen callingFigure.savefig/Figure.show. See the initial version in PR #4342pygmt/pygmt/src/psconvert.py
Lines 146 to 166 in 26c0c6d
weiji14 commentedon Jan 13, 2026
This chunk of code is a little trickier to understand/maintain. So would lean towards just raising a warning when
PS_CONVERTis used as you suggested ^.