You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Confirmed. Looks like a problem with exactly 180. Both 179.xxx and 180.xxx seems to work. @seisman, any thoughts on why 180 "blows up" somewhat? The French code must do something like divide by zero (sin (180))?
Activity
PaulWessel commentedon Nov 22, 2023
Confirmed. Looks like a problem with exactly 180. Both 179.xxx and 180.xxx seems to work. @seisman, any thoughts on why 180 "blows up" somewhat? The French code must do something like divide by zero (sin (180))?
seisman commentedon Nov 22, 2023
Need to find some time to debug it.
jpesicek commentedon Nov 22, 2023
one more:
echo 2 2 0 80.00 90.00 -140.00 5 | gmt psmeca -JX10 -R0/4/0/4 -Sa10 -N -: -L -T > plot2.ps
PaulWessel commentedon Nov 22, 2023
This time it is the "90.00" that cause trouble, it seems.
PaulWessel commentedon Jan 20, 2024
Ping @seisman on this again? Gotta be something dumb like sin(180) and then divide by it?
seisman commentedon Jan 20, 2024
OK, will look at it again next week.
jpesicek commentedon Oct 31, 2024
Just checking in on the status of this bug, thanks
jpesicek commentedon Dec 23, 2024
another note that when I use gmt4, the lines are plotted correctly