Nice, recently I've noticed that this constraint has an empty SectionPrint parameter panel and I was going to suggest that it should be removed but you made a good use of it as more options may now be supported since heat flux will be available in thermal analyses. I would just like to suggest renaming Section Load (suggesting external loads) to something like Section Forces (even if moments are included as well) or Section Forces and Moments. When it comes to Drag Stresses, we may even omit them from the selection and leave only the other 2 options. |
740d051 to
e5e57a6
Compare
e5e57a6 to
69131eb
Compare
|
Enum changed to |
Ok, I guess that we can keep one not yet supported property value. |
Variableproperty to select CalculiX section print key. (Drag Stress not yet supported)@FEA-eng