Skip to content

PwmControl.isPwmEnabled crashes #233

Closed

Description

@shelbyRobots

I am able to use a CRServoImplEx instance to use setPwmEnable/Disable.
However, isPwmEnabled crashes the app with the following:
E EventLoopManager: com.qualcomm.robotcore.exception.RobotCoreException: EventLoop Exception in loop(): IllegalArgumentException - invalid pwm channel: 4

Steps:
crsix.setPwmDisable();
...do other stuff...
if(crsix.setPwmDisable) crsix.setPwmDisable();

I was able to do a work around by keeping a local variable of pwm energize state when I call disable - to avoid calling enable on an already pwm energized port.

ServoControllerEx with port number parameter seemed to give same results.

Activity

  1. Windwoes commented on Nov 13, 2021

    @Windwoes
    Member

    Looks to be a bug in the LynxGetServoEnableCommand constructor...

    It reads

        public LynxGetServoEnableCommand(LynxModuleIntf module, int channelZ)
            {
            this(module);
            LynxConstants.validatePwmChannelZ(channelZ);
            this.channel = (byte)channelZ;
            }

    But it should be

        public LynxGetServoEnableCommand(LynxModuleIntf module, int channelZ)
            {
            this(module);
            LynxConstants.validateServoChannelZ(channelZ);
            this.channel = (byte)channelZ;
            }
  2. Windwoes commented on Dec 21, 2021

    @Windwoes
    Member

    This will be fixed in the next release of the SDK.

  3. Windwoes commented on Jan 17, 2022

    @Windwoes
    Member

    Fixed in 7.1

  4. added a commit that references this issue on Aug 14, 2025
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment