Repository navigation
set OtaCrcInitializer to OTA_VERSION_ID during binding - #2983
Merged
JyeSmith merged 3 commits intoOct 21, 2024
Merged
Conversation
mha1
reviewed
Oct 13, 2024
mha1
left a comment
Contributor
There was a problem hiding this comment.
Might want to change the comments too
// Binding uses a CRCInit=0, 50Hz, and InvertIQ
pkendall64
approved these changes
Oct 13, 2024
JyeSmith
deleted the
set-OtaCrcInitializer-to-OTA_VERSION_ID-during-binding
branch
October 21, 2024 02:15
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
It is still possible for a 2.4G Rx on V3 to receive a bind packet from a Tx on V4. The Rx will not connect correctly after receiving the bind packet, but this still should not happen.