fix(ifc): segment lengths in IFC4's base quantities and a pipe's invert in Pset_PipeSegmentOccurrence, not IFC2X3's flow-segment sets (#822) - #829

Merged
DrunkOnJava merged 6 commits into
mainfrom
fix/822-segment-sets
Oct 19, 2026
Merged

DrunkOnJava merged 6 commits into
mainfrom
fix/822-segment-sets

Conversation

@DrunkOnJava

@DrunkOnJava DrunkOnJava commented Oct 19, 2026 •

Copy link
Copy Markdown
Owner

Summary

Part 2 of #822. A pipe's or duct's length is now written in IFC4's base quantities (Qto_PipeSegmentBaseQuantities, Qto_DuctSegmentBaseQuantities, an IfcElementQuantity) and a pipe's invert in Pset_PipeSegmentOccurrence, instead of IFC2X3's flow-segment sets, on an element written as a pipe or duct segment. A proxy's Serial Number is no longer also written in Pset_PrecastConcreteElementGeneral.

Motivation

RE-131, RE-134 and RE-157 followed Revit's exports of the RE1 models, which are IFC2X3. IFC4 has no Pset_FlowSegmentPipeSegment or Pset_FlowSegmentDuctSegment, its Pset_DuctSegmentTypeCommon has no Length, and its Pset_PrecastConcreteElementGeneral no SerialNumber (buildingSMART's IFC2X3 and IFC4 definitions). Revit's IFC4 export of the BIM4LCA office writes a pipe's length in Qto_PipeSegmentBaseQuantities and its invert in Pset_PipeSegmentOccurrence. Measure's IFC4 property set check (#826) finds these four on main: 2,421 values in each flow-segment set and 1,441 duct type-set lengths on 4 exports, and 19 precast serial numbers on RE1 Electrical.

Changes

  • src/ifc/step_writer.rs, entities.rs: a PropertySet named Qto_ is written as an IfcElementQuantity whose values are IFC4 simple quantities (PropertyValue::quantity: IfcQuantityLength in metres, and areas, volumes, counts, weights and times likewise); a quantity set with no quantity is not written.
  • src/ifc/export_content.rs: a pipe gets Qto_PipeSegmentBaseQuantities.Length and Pset_PipeSegmentOccurrence.InvertElevation, a duct Qto_DuctSegmentBaseQuantities.Length, and its Pset_DuctSegmentTypeCommon keeps Shape. They are chosen by the entity the element is written as, after its Export to IFC As, so a pipe or duct written as another entity gets none. pipe_inverts_above_storeys takes the storey's elevation off only the inverts rvt-rs works out in model height (TypedProductionAppend::computed_inverts), so a pipe's parameter named Pset_PipeSegmentOccurrence.InvertElevation (RE-194) is written as it is. A Serial Number is in Pset_ManufacturerOccurrence only.
  • Tests (tests/segment_length.rs, invert_elevation.rs, duct_fields.rs, duct_segment_type_common.rs, serial_number.rs) read RE1's values from Revit's IFC2X3 sets only and rvt-rs's from the IFC4 quantities and sets only, and check that rvt-rs writes none in the IFC2X3 sets. tools/re/psets_vs_ifc.py compares an IFC2X3 reference's invert with Pset_PipeSegmentOccurrence and counts two kinds of value apart: its lengths, which IFC4 holds in quantities the scorer does not read, and its precast Serial Numbers, which IFC4 keeps in Pset_ManufacturerOccurrence, where they are scored.
  • RE-157 records the RE1 exports' schema. CHANGELOG.

Testing

Measure A/B against main (cdac7e6), run 39259646397, at c220943, both sides scored with this PR's psets_vs_ifc before e88b9c7 (which changes scoring only):

values equal to Revit's values Revit does not write
RE1 Mechanical 177 → 183 97 → 4
RE1 Plumbing 293 → 356 195 → 6
  • Each pipe's InvertElevation is Revit's in Pset_PipeSegmentOccurrence: 6 of 6 on Mechanical, 63 of 63 on Plumbing. Their 93 and 126 IFC2X3 lengths are counted apart; tests/segment_length.rs, duct_fields.rs and duct_segment_type_common.rs check them in the quantity sets against Revit's within 0.1 mm, and pass on corpus tier 2.
  • RE1 Electrical's equal values fall from 147 to 128 in that run: its 19 precast Serial Numbers, which Revit's IFC2X3 export also writes in Pset_ManufacturerOccurrence, equal on both sides (31 of 31). e88b9c7 counts them apart; a smoke run of the scorer on Revit's own file sets those 19 aside and scores the 31.
  • 5 of the 89 exports change: RE1 Mechanical, Plumbing and Electrical and Autodesk's 2025 MEP samples (advanced and basic). The other 84 are byte-identical, the BIM4LCA office among them: rvt-rs reads no length or invert for its 12 pipes.
  • The review fixes (segment sets by the entity written, the storey taken off computed inverts only) change no export: against this PR's earlier head 8351f24 (run 39254274438) only the nine exports feat(ifc): an element with no FireRating parameter takes its type's Fire Rating in its IFC4 common set (RE-77, RE-194) #830 changes differ, so no measured pipe or duct is written as another entity and none has an invert parameter.
  • IFC4 property set check (ci: Measure reports each export's standard property sets against IFC4's definitions (#822) #826): 78 of the 89 exports have no finding (77 on main). The flow-segment sets (2,421 values each), Pset_DuctSegmentTypeCommon.Length (1,441) and the precast SerialNumber (19) are gone. What is left is the fittings' Pset_PipeFittingTypeCommon.NominalDiameter on 11 exports (5,469 values), which a follow-up takes out.
  • IfcOpenShell validates all 89 head exports with no finding, the IfcElementQuantity sets included.

cargo fmt is clean. No unit tests, by the repository's rule.

Audit-honesty checklist

  • README / docs reflect the current state after this PR
  • Commit messages describe what changed and why
  • No emojis in code, docs, or commit messages
  • No private paths, personal email addresses, or internal jargon in committed files

Legal and contribution hygiene

  • I agree this work is licensable under Apache-2.0
  • This PR contains no Autodesk proprietary source, decompiled internals, or NDA'd SDK content

Based on buildingSMART's IFC2X3 and IFC4 property set definitions (CLEANROOM.md source 4) and Revit's own IFC exports of the RE1 models and the BIM4LCA office.

Breaking changes

A consumer reading a pipe's or duct's Length or a pipe's InvertElevation from the flow-segment sets finds them in the base quantities and Pset_PipeSegmentOccurrence; a proxy's Serial Number is in Pset_ManufacturerOccurrence only. pipe_inverts_above_storeys is crate-internal; TypedProductionAppend gains the public field computed_inverts.


Note

Medium Risk
Changes where MEP length, invert, and serial data appear in exported IFC4 (breaking for consumers of the old property sets), though behavior is covered by corpus tests and explicit IFC4 alignment.

Overview
Aligns IFC4 export with buildingSMART and Revit IFC4: pipe and duct segment lengths move out of IFC2X3-only flow-segment and duct type Length properties into Qto_PipeSegmentBaseQuantities / Qto_DuctSegmentBaseQuantities as IfcElementQuantity entries. Pipe invert moves from Pset_FlowSegmentPipeSegment to Pset_PipeSegmentOccurrence, with storey-relative adjustment updated to follow that set.

The STEP writer now treats any PropertySet whose name starts with Qto_ as an element quantity, mapping supported PropertyValue types via new PropertyValue::quantity() to IFC4 simple quantities (SI units in STEP). Empty quantity sets are skipped.

Serial numbers are emitted only in Pset_ManufacturerOccurrence; the duplicate Pset_PrecastConcreteElementGeneral.SerialNumber on proxies is dropped for IFC4. Duct Pset_DuctSegmentTypeCommon keeps Shape only (no length there).

Corpus tests and tools/re/psets_vs_ifc.py were updated to compare Revit IFC2X3 reference values against these IFC4 locations (including parsing IfcElementQuantity). CHANGELOG and RE-157 notes document the schema split.

Reviewed by Cursor Bugbot for commit f09359cdc6b13526b45f8cec874af0ee6f8eb2a6. Configure here.

Base automatically changed from fix/822-ifc4-reference-sets to main October 19, 2026 12:37
@DrunkOnJava
DrunkOnJava marked this pull request as ready for review October 19, 2026 12:38
@DrunkOnJava
DrunkOnJava force-pushed the fix/822-segment-sets branch 2 times, most recently from 8351f24 to ca192db Compare October 19, 2026 12:51

@chatgpt-codex-connector chatgpt-codex-connector Bot left a comment

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

💡 Codex Review

Here are some automated review suggestions for this pull request.

Reviewed commit: ca192dbe54

ℹ️ About Codex in GitHub

Your team has set up Codex to review pull requests in this repo. Reviews are triggered when you

  • Open a pull request for review
  • Mark a draft as ready
  • Comment "@codex review".

If Codex has suggestions, it will comment; otherwise it will react with 👍.

Codex can also answer questions or update the PR. Try commenting "@codex address that feedback".

Comment thread src/ifc/export_content.rs Resolved
Comment thread src/ifc/export_content.rs Resolved
Comment thread tests/segment_length.rs Resolved
…a pipe's invert in Pset_PipeSegmentOccurrence, not IFC2X3's flow-segment sets (#822)

Revit's IFC2X3 export of the RE1 models writes a segment's length in Pset_FlowSegmentPipeSegment and Pset_FlowSegmentDuctSegment (and a duct's in Pset_DuctSegmentTypeCommon), and a pipe's invert in Pset_FlowSegmentPipeSegment: IFC4 has none of these. Its IFC4 export of the BIM4LCA office writes the length in Qto_PipeSegmentBaseQuantities and the invert in Pset_PipeSegmentOccurrence. A PropertySet named Qto_ is now written as an IfcElementQuantity of IFC4 simple quantities.
…eteElementGeneral, which IFC4 gives none (#822)

Revit's IFC2X3 export of the RE1 models gives a building-element proxy's Serial Number in Pset_PrecastConcreteElementGeneral as well as Pset_ManufacturerOccurrence; IFC4's Pset_PrecastConcreteElementGeneral has no SerialNumber, so only Pset_ManufacturerOccurrence holds it. A Qto_ set with no quantity is not written: an IfcElementQuantity holds one at least.
…pipe's own invert parameter keeps its value (#822)

Qto_PipeSegmentBaseQuantities, Qto_DuctSegmentBaseQuantities, Pset_PipeSegmentOccurrence and the duct's Pset_DuctSegmentTypeCommon are chosen by the entity an element is written as, not its Revit class, so a pipe or duct whose Export to IFC As writes it as another entity gets none of them. The storey elevation comes off only the invert rvt-rs works out in model height, by the sets' indices, so a pipe's parameter named Pset_PipeSegmentOccurrence.InvertElevation (RE-194) is written as it is.
…FC4 ones apart (#822)

Revit's lengths, inverts and references are read from its IFC2X3 sets only and rvt-rs's from the IFC4 quantities and sets only, so the tests fail if rvt-rs writes them in IFC2X3's sets alone, and each checks rvt-rs writes none there.
…part, as IFC4 keeps it in Pset_ManufacturerOccurrence (#822)

Revit's IFC2X3 export of RE1 Electrical writes each of 19 Serial Numbers in both Pset_PrecastConcreteElementGeneral and Pset_ManufacturerOccurrence. IFC4 keeps only the second, which rvt-rs writes and the scorer compares (31 of 31), so the first is counted apart instead of as missing.
@DrunkOnJava
DrunkOnJava merged commit 7d8e8fd into main Oct 19, 2026
25 checks passed
@DrunkOnJava
DrunkOnJava deleted the fix/822-segment-sets branch October 19, 2026 14:08
DrunkOnJava added a commit that referenced this pull request Oct 19, 2026
…ot in Pset_PipeFittingTypeCommon, which IFC4 gives none (#822) (#833)

## Summary

Part 5 of #822, its last IFC2X3 property. RE-165's pipe fitting
`NominalDiameter` moves from `Pset_PipeFittingTypeCommon`, where IFC2X3
has it and IFC4 does not, to rvt-rs's own `RvtElementRecordGeometry`
set. With it, Measure's IFC4 property set check (#826) finds nothing on
any of the 89 exports.

## Motivation

IFC4's `Pset_PipeFittingTypeCommon` has no `NominalDiameter`
(buildingSMART's IFC4 definitions); after #829 the check found 5,469
such values on 11 exports. IFC4 keeps a pipe connection's nominal
diameter on its port (`Pset_DistributionPortTypePipe`), but Revit's IFC4
export writes no such set: revit-ifc certifies
`Pset_DistributionPortCommon` and none of the typed port sets for the
IFC4 Reference View or Design Transfer View
(`IFCCertifiedEntitiesAndPSets.json`), and its Reference View export of
the BIM4LCA office writes no property set on any of its 67 ports. With
no IFC4 placement that Revit's export uses, the measured value goes to
rvt-rs's own set, as RE-187's door type sizes do.

## Changes

- `src/ifc/export_content.rs`: a fitting's nominal diameter is one
length, `NominalDiameter`, in its `RvtElementRecordGeometry` set;
`Pset_PipeFittingTypeCommon.NominalDiameter` is no longer written.
- `tests/fitting_nominal_diameter.rs`: reads Revit's file from
`Pset_PipeFittingTypeCommon` only and rvt-rs's from its own set only,
and checks that rvt-rs writes none in `Pset_PipeFittingTypeCommon`.
- `tools/re/psets_vs_ifc.py`: counts an IFC2X3 reference's fitting
`NominalDiameter` apart, as rvt-rs's own set is not scored.
- `partition_fitting_sizes` module documentation, `PropertyValue::List`
documentation, CHANGELOG.

## Testing

Measure A/B against #829's head (c220943), run
[39263341670](https://github.com/DrunkOnJava/rvt-rs/actions/runs/39263341670),
at 16ec4e9, whose `src` and `tests` are this branch's (it was rebased
onto `main` once #829 landed), both sides scored with this PR's
`psets_vs_ifc`:

- IFC4 property set check: all 89 exports have no finding (78 before;
the other 11 had 5,469 `NominalDiameter` values). IfcOpenShell validates
all 89 with no finding.
- 11 exports change, the ones with fittings: RE1 Mechanical and
Plumbing, Autodesk's 2024 to 2027 MEP samples (advanced and basic) and
Snowdon Towers' plumbing model.
- RE1 Plumbing: the 46 values rvt-rs wrote in
`Pset_PipeFittingTypeCommon` (on Revit's 42 fittings and 4 more) leave
the values Revit's export does not hold, 48 → 2; Revit's 42 IFC2X3
diameters are counted apart on both sides, so equal values read 314 here
where #829's scorer, which compared them, read 356. RE1 Mechanical:
rvt-rs's 3, which Revit's export does not write, likewise (4 → 1).
- `tests/fitting_nominal_diameter.rs` compares Revit's 42 diameters with
rvt-rs's own set within a relative 1e-5 on corpus tier 2.

`cargo fmt` is clean. No unit tests, by the repository's rule.

## Audit-honesty checklist

- [x] README / docs reflect the current state after this PR
- [x] Commit messages describe what changed and why
- [x] No emojis in code, docs, or commit messages
- [x] No private paths, personal email addresses, or internal jargon in
committed files

## Legal and contribution hygiene

- [x] I agree this work is licensable under Apache-2.0
- [x] This PR contains no Autodesk proprietary source, decompiled
internals, or NDA'd SDK content

Based on buildingSMART's IFC2X3 and IFC4 property set definitions
(CLEANROOM.md source 4), Revit's own IFC exports of the RE1 models and
the BIM4LCA office, and revit-ifc's `IFCCertifiedEntitiesAndPSets.json`
(CLEANROOM.md source 5, read and cited).

## Breaking changes

`Pset_PipeFittingTypeCommon.NominalDiameter` is no longer written; a
fitting's nominal diameter is
`RvtElementRecordGeometry.NominalDiameter`, one length rather than a
list of one.

<!-- CURSOR_SUMMARY -->
---

> [!NOTE]
> **Medium Risk**
> Breaking IFC export contract for consumers that read
`Pset_PipeFittingTypeCommon.NominalDiameter`; behavior is localized to
pipe fitting property emission and validation tooling.
> 
> **Overview**
> **Pipe fitting nominal diameter** no longer lands in
`Pset_PipeFittingTypeCommon` (IFC4 has no `NominalDiameter` there).
Export now writes the same measured value as a **single length**
`NominalDiameter` on rvt-rs’s `RvtElementRecordGeometry` set, alongside
other record geometry properties.
> 
> Corpus and tooling follow that split:
`tests/fitting_nominal_diameter.rs` compares Revit’s IFC2X3 reference
from the old set, asserts rvt-rs does not emit the legacy property, and
checks values in the own set; `tools/re/psets_vs_ifc.py` excludes this
IFC2X3-only property from the IFC4 property-set score. Docs and
CHANGELOG note the breaking export shape (list of one → one length, new
location).
> 
> <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit
1080604. Configure
[here](https://www.cursor.com/dashboard/bugbot).</sup>
<!-- /CURSOR_SUMMARY -->
DrunkOnJava added a commit that referenced this pull request Oct 19, 2026
…al port is SOURCEANDSINK (#828) (RE-197) (#832)

## Summary

Closes #828. Each port's `PredefinedType` is its connector's domain
(`DUCT`, `CABLE`, `PIPE`), as Revit's IFC4 export types it, and a
connector of a domain Revit's exporter gives no direction, every one but
HVAC and piping, is `SOURCEANDSINK`. RE-197 records the measurement and
the negatives: an HVAC or piping connector's direction and a port's
`SystemType` are not in what rvt-rs reads, and Revit's IFC4 Reference
View export writes no port property set.

## Motivation

rvt-rs wrote every port with `FlowDirection` `.NOTDEFINED.` and no
`PredefinedType`. Revit's IFC4 export of the BIM4LCA office writes all
67 of its ports `SOURCEANDSINK`, 43 `CABLE` / `ELECTRICAL` and 24 `PIPE`
/ `HEATING`. A port's `PredefinedType` also decides which IFC4 port
property sets apply to it.

## Changes

- `src/native_connectors.rs`: `symbol_port_indices` returns each
connector's domain with its index; `port_type_of_domain` maps HVAC to
`DUCT`, electrical to `CABLE`, piping to `PIPE` and an undefined domain
to `NOTDEFINED` (a cable tray or conduit connector has no port, RE-169);
`port_flow_direction_of_domain` gives `SOURCEANDSINK` for every domain
but HVAC and piping, as revit-ifc's `ConnectorExporter` does.
- `src/ifc/entities.rs`, `export_content.rs`, `mod.rs`,
`step_writer.rs`: `IfcEntity::Port` carries `predefined_type` and
`flow_direction`; a duct's or pipe's two ports are `DUCT` or `PIPE`,
with no direction; the writer fills `FlowDirection` and
`PredefinedType`, `NOTDEFINED` and `$` where nothing is read.
- `examples/probe_re197_connector_directions.rs`: tallies every field of
a family's `ConnectorDataCell`, and of the `FamilyParams` object its
`m_oRelevantParams` points to, against the direction of the port in
Revit's export.
- `tools/re/ports_vs_ifc.py`: compares `FlowDirection`, `PredefinedType`
and `SystemType` on the ports both exports hold, only those the schema
of Revit's export gives a port (an IFC2X3 port has `FlowDirection`
only).
- RE-197 report; the ports row of the support matrix, which also drops
what B83, B84 and RE-169 made stale (proxies have ports, every port is
nested, 73 of 73 and 126 of 126 connections); README; CHANGELOG.

## Testing

Measure A/B against `main` (cdac7e6), run
[39261416282](https://github.com/DrunkOnJava/rvt-rs/actions/runs/39261416282),
at f5a2216, both sides scored with this PR's `ports_vs_ifc`:

| | `PredefinedType` equal | `FlowDirection` equal |
|---|---:|---:|
| BIM4LCA office, as built (67 ports) | 0 → 67 | 0 → 43 |
| BIM4LCA office, building permit (67 ports) | 0 → 67 | 0 → 43 |
| RE1 Electrical (53 ports, IFC2X3) | not in the schema | 0 → 53 |
| RE1 Mechanical (150 ports, IFC2X3) | not in the schema | 0 → 1 |
| RE1 Plumbing (260 ports, IFC2X3) | not in the schema | 0 → 1 |

- No port takes a direction Revit's export does not give it, on any of
the five models.
- Left as before: the office's 24 pipe ends (`SOURCEANDSINK` in Revit's
export, `NOTDEFINED` here) and RE1's HVAC and piping ports, whose
direction is not read; `SystemType` on all 67 office ports.
- Ports and connections are unchanged: Mechanical 73 of 73 connections
and 150 of 150 ports, Plumbing 126 of 126 with 2 not in Revit's export,
every port tied to its element.
- 29 of the 89 exports change, every one with ports. IfcOpenShell finds
nothing on any of the 89.
- The probe (runs
[39253573356](https://github.com/DrunkOnJava/rvt-rs/actions/runs/39253573356),
[39255994320](https://github.com/DrunkOnJava/rvt-rs/actions/runs/39255994320),
[39256707456](https://github.com/DrunkOnJava/rvt-rs/actions/runs/39256707456)):
no field of the connector cell or its `FamilyParams` object separates In
from Out ports; every electrical connector's port is `SOURCEANDSINK`, 98
of 98.

Final A/B on `main` after #829 (7d8e8fd), run
[39267434693](https://github.com/DrunkOnJava/rvt-rs/actions/runs/39267434693),
at a2a8897: every port figure above is the same, the same 29 exports
change, IfcOpenShell finds nothing on any of the 89, and no port takes a
direction Revit's export does not give it. The review fixes after it
(0070b76: port values only from IFC4's enumerations, and the unread
electrical description override stated) change no export, as every value
the exporter writes is in those enumerations, and #833, merged since,
changes no port.

`cargo fmt` is clean. No unit tests, by the repository's rule.

## Audit-honesty checklist

- [x] README / docs reflect the current state after this PR
- [x] Commit messages describe what changed and why
- [x] No emojis in code, docs, or commit messages
- [x] No private paths, personal email addresses, or internal jargon in
committed files

## Legal and contribution hygiene

- [x] I agree this work is licensable under Apache-2.0
- [x] This PR contains no Autodesk proprietary source, decompiled
internals, or NDA'd SDK content

Based on byte observations of the RE1 models and the BIM4LCA office
against Revit's own IFC exports of them, and revit-ifc's
`ConnectorExporter`, `ElementFilteringUtil` and
`IFCCertifiedEntitiesAndPSets.json` (CLEANROOM.md source 5, read and
cited, no code copied).

## Breaking changes

`ifc::entities::IfcEntity::Port` gains the fields `predefined_type` and
`flow_direction`, so code constructing it names both;
`native_connectors::symbol_port_indices` returns `(index, domain)`
pairs. An export's ports now carry `PredefinedType` and, where the
domain gives one, `FlowDirection` `SOURCEANDSINK`.

<!-- CURSOR_SUMMARY -->
---

> [!NOTE]
> **Medium Risk**
> Changes IFC MEP port semantics and a public `IfcEntity::Port` shape;
behavior is bounded to match Revit on measured models but HVAC/piping
directions remain intentionally incomplete.
> 
> **Overview**
> **IFC `IfcDistributionPort` export now follows Revit's
connector-domain rules (RE-197 / #828).** Each port gets a
**`PredefinedType`** from its connector domain (`DUCT`, `CABLE`, `PIPE`,
or `NOTDEFINED`), and **`FlowDirection` `SOURCEANDSINK`** for every
domain except HVAC and piping, where direction stays **`NOTDEFINED`**
because the family connector setting is not read. Duct and pipe end
ports are typed **`DUCT`** / **`PIPE`** accordingly.
> 
> `IfcEntity::Port` carries `predefined_type` and `flow_direction`;
`native_connectors` adds `port_type_of_domain` /
`port_flow_direction_of_domain` and returns connector **domains** with
symbol port indices. The STEP writer emits those attributes on
`IFCDISTRIBUTIONPORT` instead of always `.NOTDEFINED.` and `$`.
> 
> **Measurement and docs:** `tools/re/ports_vs_ifc.py` scores
**`FlowDirection`**, **`PredefinedType`**, and **`SystemType`** against
Revit's export; a new probe and RE-197 report document the rule and
limits (`SystemType` and HVAC/piping direction still unset). Changelog,
README, and the support matrix are updated with BIM4LCA / RE1 Electrical
parity numbers.
> 
> <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit
a2a8897. Configure
[here](https://www.cursor.com/dashboard/bugbot).</sup>
<!-- /CURSOR_SUMMARY -->
@DrunkOnJava DrunkOnJava mentioned this pull request Oct 19, 2026
6 tasks done
DrunkOnJava added a commit that referenced this pull request Oct 19, 2026
## Summary

Prepare v0.6.0. Merging this is not the release: the release is the signed `v0.6.0` tag on the merged commit, after the maintainer's go-ahead. This stays a draft until then.

## Motivation

Since 0.5.1, `main` has:

- **IFC4's own property sets (#822):** the IFC2X3 sets 0.5 took from Revit's exports of the RE1 models are gone or moved to where IFC4 and Revit's own IFC4 export put them (#825, #829, #833), and Measure checks every export's standard property sets against buildingSMART's published IFC4 property set definitions (#826). That is rvt-rs's own check: buildingSMART's Validation Service has not been run on the exports, and quantity sets are not checked.
- **More of what Revit's exporter writes:** parameters named for an IFC4 property set's property (RE-194, #815, #817/#821), each element's `IsExternal` (RE-193, #814), a type's Fire Rating (#830), a door's overall size (#788), Revit 2024 Areas as spaces (#811), port types and electrical flow directions (#832), rooms with no number (#818), pieces' property sets (#819), a room's floor finish in IFC4's set (#820).
- **Older and newer releases, experimentally:** Revit 2015 to 2022 (#742) and 2027 (#740) element records.
- **Fixes:** Export to IFC As on fixtures, stairs, doors, curtain walls and wall sweeps (#796, #804, #812, #813), the latest copy of an element's or type's data (#803, #809), declared ElementIds (#797), diagnostics naming the file, not its folders (#785), the browser viewer's wasm32 string-length panic (#835), and `rvt-inspect`, `rvt-corpus doctor` and the viewer's File Status taking Revit 2015 and 2027 as releases rvt-rs reads (#838).
- **CI and release:** IfcOpenShell 0.9.0.post1 (#795), Rust installed with rustup (#793), a tag publishes nothing until the maintainer approves it (#786, #787), and Measure's office, R2025, paired-probe and per-sample hashing (#790, #799, #805, #806).

## Changes

- **Versions 0.5.1 → 0.6.0** in the nine files that carry them: `rvt`, `rvt-py` and its pin, `rvt-wasm`, the `stream_evidence` pin, `CITATION.cff` (with `date-released`), `.release-please-manifest.json`, `viewer/package.json` and both lockfiles' workspace entries.
- **CHANGELOG:** `[0.6.0] — 2026-10-19`, with an introduction, **Upgrading from 0.5** (the property sets that moved, the public API changes, the releases that now export elements) and the outside contributors credited: puzzbobb (#740, #742, #798), Erry91 (#788) and MadsHolten (#835). The section's headings were already single; its 41 entries are all kept, with #835's and #838's added. Its introduction says the property sets match buildingSMART's published IFC4 definitions by rvt-rs's own check, as does the README's release summary.
- **README:** "Release 0.6.0 and main" names v0.6.0 and summarises what it added. The lines that said `main` reads Revit 2015 to 2022 and 2027 now say experimental (since 0.6.0). The opening and "Not yet" lines name those releases, and so does the capability table. The bullet list of what 0.5.0 added is gone; #832 had put 0.6.0's port types in it. As Codex found, the IFC4 export row, the viewer paragraph and the decoder-work paragraph also said 2022 and earlier export only the scaffold, and the by-input table skipped 2014; they name 2015 to 2022, 2026 and 2027 now.
- **Witnesses:** the IFC header carries the version, so both Core Interior `rvt-rs.json` observations and their verdicts are refreshed from this pull request's CI run.

## Testing

- CI on this pull request, the witness replays included.
- Measure on `main` at 23a9d76, which is everything in this release but #835's wasm32-only fix and #838's CLI and viewer version range, neither of which changes an export: run [39273188597](https://github.com/DrunkOnJava/rvt-rs/actions/runs/39273188597). All 89 exports (the reference models, both BIM4LCA office files, Autodesk's 58 sample projects and the 23 R2025 models) have no finding in Measure's IFC4 property set check (#826, against buildingSMART's published definitions), and IfcOpenShell's schema validation finds nothing on any of the 89; none was too large to validate.
- Witnesses: both Core Interior observations and verdicts are taken from this pull request's CI run 39275014518; only `witness_version` and the verdict hashes differ, and CI's replay on b82c0c3 passes.

## Audit-honesty checklist

- [x] README / docs reflect the current state after this PR
- [x] Commit messages describe what changed and why
- [x] No emojis in code, docs, or commit messages
- [x] No private paths, personal email addresses, or internal jargon in committed files

## Legal and contribution hygiene

- [x] I agree this work is licensable under Apache-2.0
- [x] This PR contains no Autodesk proprietary source, decompiled internals, or NDA'd SDK content

## Breaking changes

See **Upgrading from 0.5** in the CHANGELOG: standard property sets moved to IFC4's, and five public API changes.

<!-- CURSOR_SUMMARY -->
---

> [!NOTE]
> **Low Risk**
> Version and documentation-only release prep with no runtime code changes in this PR.
> 
> **Overview**
> **Bumps the workspace from 0.5.1 to 0.6.0** across `Cargo.toml`, `rvt-py` / `rvt-wasm` / `stream_evidence` pins, lockfiles, `viewer/package.json`, `.release-please-manifest.json`, and `CITATION.cff` (release date 2026-10-19).
> 
> **Documents the release:** adds the `[0.6.0]` section to `CHANGELOG.md` (IFC4 property sets, broader Revit export parity, experimental 2015–2022/2027 element export, wasm viewer fix, and **Upgrading from 0.5** breaking notes). **README** now treats v0.6.0 as the current release—updates the support matrix and “Release 0.6.0 and main” to describe shipped capabilities instead of the old 0.5.1 bullet list.
> 
> No application or library source changes in this diff; it packages and narrates work already on `main`.
> 
> <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit c8826b82982270fd4f47b8da656f2e3e6021c76b. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup>
<!-- /CURSOR_SUMMARY -->
Repository owner deleted a comment from chatgpt-codex-connector Bot Oct 31, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant