Skip to content

red: B86 MEP joins test - #707

Closed
DrunkOnJava wants to merge 6 commits into
mainfrom
red/b86-proxy-connections
Closed

DrunkOnJava wants to merge 6 commits into
mainfrom
red/b86-proxy-connections

Conversation

@DrunkOnJava

@DrunkOnJava DrunkOnJava commented Oct 5, 2026 •

Copy link
Copy Markdown
Owner

Red check for B86's test, on top of B83 (#705). Closed once the failing output is recorded.


Note

Medium Risk
Changes IFC export topology for MEP ports on building element proxies; behavior is constrained by new corpus parity tests but affects interoperability with tools that consume port relationships.

Overview
IFC4 proxy MEP ports now follow Revit’s export: family instances emitted as IfcBuildingElementProxy get connector ports from the same native path as distribution elements, and the STEP writer nests those ports under the proxy with IfcRelNests instead of IfcRelConnectsPortToElement (IFC4 only ties ports to distribution elements).

Port-to-port joins (IfcRelConnectsPorts) are unchanged; only how a proxy’s ports attach to their host element differs. Distribution elements still use IfcRelConnectsPortToElement.

Regression coverage adds corpus tests (proxy_ports, proxy_connections) against Revit’s RE1-*.ifc when RVT_PROJECT_CORPUS_DIR is set, plus CI targets and an update to ports_vs_ifc.py so scoring treats nested proxy ports like Revit’s IFC4 export.

Reviewed by Cursor Bugbot for commit f4e9d4c. Configure here.

…ests them (B83)

Revit's export of RE1 Electrical writes 30 of its 53 ports on elements both
it and rvt-rs write as proxies. IFC4 ties a port to a distribution element
only through IfcRelConnectsPortToElement, and Revit's own IFC4 export
nests every port in its element with an IfcRelNests. For every port Revit
writes on an element rvt-rs writes as an IfcBuildingElementProxy, rvt-rs
must write the port Port_<ElementId>_<index>, nested in that element.

Red on draft #704, Corpus health run 37299353664:

    RE1-Electrical.rvt: 0 of Revit's 30 ports on proxies written, nested in their element
    RE1-Plumbing.rvt: 0 of Revit's 0 ports on proxies written, nested in their element
    RE1-Mechanical.rvt: 0 of Revit's 6 ports on proxies written, nested in their element
    thread 'proxies_have_revits_ports_nested' panicked at tests/proxy_ports.rs:171:5:
    RE1-Electrical.rvt: 30 of Revit's 30 ports on family instances rvt-rs writes as proxies are not written nested in their element; first: [(428352, 1), (476276, 1), (476469, 1), (476602, 1), (477108, 1), (477740, 1), (477846, 1), (477893, 1)]
    RE1-Mechanical.rvt: 6 of Revit's 6 ports on family instances rvt-rs writes as proxies are not written nested in their element; first: [(427568, 6), (427568, 7), (427568, 8), (427568, 9), (427568, 10), (427568, 11)]
    test result: FAILED. 0 passed; 1 failed; 0 ignored; 0 measured; 0 filtered out; finished in 2.49s
… in it (B83)

Revit's export of RE1 Electrical writes 30 of its 53 ports on elements both
it and rvt-rs write as proxies (panels, receptacles, switches, junction
boxes, sensors). rvt-rs gave ports to distribution elements only, as it ties
each with an IfcRelConnectsPortToElement, which IFC4 restricts to
distribution elements. Revit's own IFC4 export (revit-ifc ConnectorExporter)
nests every port in its element with an IfcRelNests named NestedPorts.

- attach_family_instance_ports gives a proxy a port per symbol connector,
  as it does a distribution element (RE-169).
- The writer nests a proxy's ports in it, one IfcRelNests per proxy
  ('NestedPorts', 'Flow'); every other port keeps its
  IfcRelConnectsPortToElement.
- tools/re/ports_vs_ifc.py reads nested ports as tied to their element.
@DrunkOnJava DrunkOnJava changed the title red: B86 proxy connections test red: B86 MEP joins test Oct 5, 2026
@DrunkOnJava

Copy link
Copy Markdown
Owner Author

Red recorded (Corpus health run 37302264599). The implementation reads joins from the family instances' native connectors (RE-171) and is in the B86 pull request.

@DrunkOnJava DrunkOnJava closed this Oct 5, 2026
DrunkOnJava added a commit that referenced this pull request Oct 5, 2026
…native connectors (B86, RE-171) (#716)

B86, the rest of B54 (#528): the 13 joins of Revit's RE1 export that
rvt-rs did not read.

**Red.** `tests/mep_connections.rs` requires every join Revit's export
writes between two elements rvt-rs writes with ports, and no join rvt-rs
writes between two elements Revit holds that is not Revit's. On draft
#707 (Corpus health run 37302264599) it failed with Plumbing 6 of 126
not written and Mechanical 7 of 73. That red result was in hand before
the native implementation below was written. The proxy-filter commit was
written while that run was still going.

**What reads the joins.** A `FamilyInstance` record holds a `Connector`
object per connector. Each one gives its index (`m_nIndex`) and lists,
in `m_arrRefs`, the elements joined to it with their connector indices
and a connection type. RE-171's probe (run 37303312731) scored the
type-1 references against Revit's exports:

| model | Revit's joins | native type-1 references | not Revit's |
|---|---:|---:|---:|
| RE1 Mechanical | 73 | 73 | 0 |
| RE1 Plumbing | 126 | 126 | 2 (both on tank 442378, which Revit's
export leaves out, RE-169) |

`native_connectors::family_instance_joins` reads them from the MEP
categories' family instances, selected by id. The export uses them
wherever the native record path reads the file (Revit 2023 to 2027). The
byte-form lists (RE-138, RE-141) remain the fallback on 2025, the one
release they are measured on. Joins whose other end is a proxy are now
written, because proxies carry ports since B83.

**Why not widen the byte form.** A side agent pointed out that the
alternative, accepting lists with any terminal or equipment first, found
anywhere, with indices up to 31, would be matched on bytes alone, and
only RE1 could catch a false match. On Autodesk's 2025 MEP samples that
version added 252 and 249 joins. The native connectors there hold 2,609
and 2,652. The byte form disagrees with them in two ways (runs
37303169279, 37306537328):
- **Duct ends.** 207 of main's 265 joins that native lacks are the same
two elements joined at the other end of the duct. That is the
earlier-copy inversion rule, measured on RE1 only, misreading the
samples.
- **Impossible joins.** Main joins 11 and 12 duct or pipe ends twice,
which cannot happen. Native joins none twice, on every file.

**Measure** (run 37306537328, head 55a6830 against `main` plus the
join-list probe):
- **RE1.** Mechanical 73 of 73 and Plumbing 126 of 126 joins written.
The only two not in Revit's export are the tank's. No port is untied,
and there are no schema findings.
- **Samples.** The 2024, 2025 and 2026 MEP samples each write 2,609
(`rme_advanced`) and 2,652 (`rme_basic`) joins, the same project in
three releases. 2024 and 2026 wrote none before.
- **Unchanged.** Every other model's and sample's output is identical.
- **Timing (one runner).** Core Interior, Einhoven, the architecture
samples and 2027 read 0.93 to 1.03. The MEP samples read 1.06 to 1.16,
because they now decode their MEP instances' records and write about
2,600 more joins each.

The probes `examples/probe_re171_connector_refs.rs` and
`examples/probe_re170_join_list.rs`, and the RE-170 and RE-171 report,
follow in their own research pull request.

<!-- CURSOR_SUMMARY -->
---

> [!NOTE]
> **Medium Risk**
> Changes how MEP joins are discovered and which IFC port connections
are emitted, with broad impact on MEP exports but a version fallback and
new regression test against Revit reference exports.
> 
> **Overview**
> MEP connector joins are now taken primarily from **native
`FamilyInstance` connector references** (type-1 `m_arrRefs` entries) via
`native_connectors::family_instance_joins`, scoped to 18 MEP
equipment/terminal classes so full-model furniture decode is avoided.
When native records are unavailable, the existing **byte-form**
`partition_connector_pairs` scans remain the fallback on supported Revit
versions.
> 
> Decoded join fields are attached to **any element** that has pairs,
not only ducts, pipes, and fittings—so terminals, equipment, and similar
instances participate in export.
> 
> IFC **`IfcRelConnectsPorts`** emission treats
**`IfcBuildingElementProxy`** as port-bearing alongside distribution
elements, so joins involving proxies (e.g. mechanical AHU to ducts) are
written when both ends export with ports.
> 
> A new **`mep_connections`** corpus test compares port-to-port joins in
rvt-rs STEP output against Revit’s reference IFC for RE1 Electrical,
Plumbing, and Mechanical; CI includes this target.
> 
> <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit
dc2771c. Configure
[here](https://www.cursor.com/dashboard/bugbot).</sup>
<!-- /CURSOR_SUMMARY -->
@DrunkOnJava
DrunkOnJava deleted the red/b86-proxy-connections branch October 18, 2026 09:37
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant