feat(ifc): a family instance has a port for each of its symbol's connectors, joined or not (B54) - #680
Merged
Conversation
…s Revit's export writes them (B54) Revit's export of the RE1 MEP models writes a port for every connector of a family instance, joined or not. tests/family_instance_ports.rs requires rvt-rs to write each such port on an element it writes as a distribution element, Port_<ElementId>_<index>, tied to the element with that Tag. Red on main (draft #678, run 37230564190, "Corpus health (tier 2)"): RE1-Electrical.rvt: 0 of Revit's 23 family-instance ports written RE1-Plumbing.rvt: 128 of Revit's 136 family-instance ports written RE1-Mechanical.rvt: 78 of Revit's 82 family-instance ports written panicked at tests/family_instance_ports.rs:173:5: RE1-Electrical.rvt: 23 of Revit's 23 ports on family instances rvt-rs writes as distribution elements are not written, tied to their element; first: [(441149, 1), (441150, 1), (441151, 1), (441152, 1), (441153, 1), (441154, 1), (441155, 1), (441156, 1)] RE1-Plumbing.rvt: 8 of Revit's 136 ports on family instances rvt-rs writes as distribution elements are not written, tied to their element; first: [(442581, 1), (442625, 1), (443223, 1), (443279, 1), (443513, 1), (446093, 2), (446093, 4), (447727, 1)] RE1-Mechanical.rvt: 4 of Revit's 82 ports on family instances rvt-rs writes as distribution elements are not written, tied to their element; first: [(433643, 1), (433747, 1), (490317, 1), (491631, 1)]
…ectors, joined or not (B54) A FamilySymbol's native record lists its connectors in m_arrConnectorData (each an m_index), and its Family holds a ConnectorDataCell per connector with its domain. On RE1 Electrical, Plumbing and Mechanical every family instance Revit writes ports for has exactly its symbol's connector indices, the cable tray and conduit ones (domain 4) aside (Measure run 37230166352: one panel's five conduit connectors get no port). rvt-rs wrote ports only for joins it read. native_connectors::symbol_port_indices reads the indices through the native record path (2023 to 2027) and the export gives each family instance it writes as a distribution element a port for each; the writer skips a port a join has already given. A release the native path does not read keeps its join ports.
DrunkOnJava
enabled auto-merge (squash)
October 4, 2026 20:20
DrunkOnJava
added a commit
that referenced
this pull request
Oct 4, 2026
…ectors (B54, B38) (#681) The research behind #680, with its probes. - A FamilySymbol's native record lists its connectors (m_arrConnectorData, m_index); its Family has a ConnectorDataCell per index with the domain. On RE1 Electrical, Plumbing and Mechanical, every family instance's ports in Revit's export are its symbol's connector indices. The cable tray and conduit domain is the exception: one panel's five conduit connectors get no port (run 37230166352). - B38: RE1 Plumbing's tank 442378, which Revit's export leaves out, was created in New Construction, is demolished in no phase, is in the main model and is visible. No record in the file holds DontExport, IfcExportAs or IFCExport. It differs from the exported fixtures only in being unhosted and level-based. Why Revit leaves it out stays open (runs 37229407104, 37229769241). <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Low Risk** > Additive research examples and documentation only; no library or export behavior changes in this diff. > > **Overview** > Adds **RE-169 research artifacts** (backlog B54/B38, issues #528/#328) documenting how Revit IFC ports map to family-symbol connectors and why one plumbing tank is missing from Revit's export. > > Three new **`examples/` probes** drive measure workflows: `probe_re169_symbol_connectors` compares Revit `IFCDISTRIBUTIONPORT` indices to native `FamilySymbol`/`Family` connector data on RE1 MEP models; `probe_re169_tank_fields` dumps native fields for tank 442378 vs an exported fixture; `probe_re169_export_flag` scans the model for `DontExport` / `IfcExportAs` / `IFCExport` and related family references. > > The report **`reports/element-framing/RE-169-symbol-connectors.md`** records findings: exported ports match symbol connector indices (except cable-tray/conduit domain on one panel), ties the conclusion to **#680** (`native_connectors::symbol_port_indices`), and notes tank 442378 is visible/unflagged but unhosted—export omission remains unexplained. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit 4c7cd61. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
DrunkOnJava
added a commit
that referenced
this pull request
Oct 4, 2026
Measure appends `milliseconds <n>` to each model's and sample's rvt-ifc.log, so a slower export shows up in the base/head comparison like any other output change. Run 37237567160 used it to time main against 8cdfba1, the commit before #680: the native passes added by #680 and #684 cost about 1 to 4 s per MEP export and nothing on 2016 to 2022. <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Low Risk** > CI-only timing instrumentation in the measure script; no runtime or export behavior changes. > > **Overview** > The Measure CI script now records **wall-clock time** for each `rvt-ifc` export on reference models and Autodesk sample projects. > > Before each export it captures a nanosecond timestamp; after the run it appends `milliseconds <n>` to that model's `rvt-ifc.log` (alongside the existing exit status). Base/head artifact diffs can then surface export slowdowns the same way as other log changes. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit c951e05. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
DrunkOnJava
added a commit
that referenced
this pull request
Oct 4, 2026
…rameter-definition pass (B80) (#690) native_document::extract first decodes every parameter-definition owner in the file (for saved parameter values), then makes its selected pass. The export's two native consumers, family-instance ports (#680) and duct shapes (#684), read objects' fields only. They now call the new extract_graphs, which makes the selected pass alone. Measure run 37241187730 (samples, against main) shows the IFC byte-identical on all six models and 36 samples. Wall time across them falls from 288.8 s to 226.8 s: | file | main | this PR | |---|---:|---:| | 2025 rme_advanced | 44.9 s | 32.3 s | | 2025 rme_basic | 39.5 s | 28.7 s | | 2024 rme_advanced | 32.9 s | 23.8 s | | 2026 rme_advanced | 30.7 s | 22.6 s | | 2025 rac_advanced | 5.8 s | 4.5 s | <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Low Risk** > Targeted performance path change with measured IFC parity; only affects native readers that do not rely on resolved parameter definitions. > > **Overview** > Adds **`native_document::extract_graphs`**, which runs the selected-record object-graph pass only—skipping **`extract`**'s upfront scan of every parameter-definition owner in the file. Callers that read native object fields (not saved parameter values) no longer pay that definition-ingest cost. > > **Family-instance port indices** (`symbol_port_indices`) and **duct type shapes** (`duct_type_shapes`) now use `extract_graphs` instead of `extract` for their FamilySymbol/Family and `AbsDuctType` passes. Saved metadata on those records is projected with an empty definition registry, which matches graph-only field reads. > > Export output stays byte-identical on measured models; wall time drops materially because the definition pass is avoided on these hot paths (B80). > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit 4684b53. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
DrunkOnJava
added a commit
that referenced
this pull request
Oct 5, 2026
#680 to #728 (#729) BACKLOG.md and CHANGELOG.md for this stretch of session 3: B74 and B79 to B87, the CI audit's items C1 to C10 with their pull requests and evidence, Corpus health's failure rate without the red drafts, zizmor's first findings, the writer-path coverage, and the CHANGELOG entries for the user-visible changes (MEP export speed, ports and joins, the rvt-wasm crate). It merges last, after the pull requests it describes. <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Low Risk** > Documentation-only changes to backlog and release notes; no runtime, export, or CI behavior is modified in this PR. > > **Overview** > Updates **maintainer docs only** (`BACKLOG.md`, `CHANGELOG.md`) to reflect session 3 work through early October 2025—no application or CI workflow code in this diff. > > **`CHANGELOG.md` [Unreleased]** gains user-facing notes for merged work: MEP ports/joins/nesting (B54, B83–B86, B84), duct naming and `Shape` (B59, B43), space types (B78), `--saved-meshes` on 2025/2026 (B77), `typed-no-geometry` typing fix (B74), the **`rvt-wasm`** split (C6), and the **B80** perf stack (native graph reuse, partition scans, SIMD Adler-32, shared extractions, room-outline pass, curve scan bounds). Measure timing/`ifc_flags` (B81) and research notes (e.g. RE-169) are added; the interim B77 restriction on `--saved-meshes` is removed in favor of the measured enablement. > > **`BACKLOG.md`** re-ranks and closes many items (B43, B59, B74, B76–B83, B85, B87, etc.), marks B54/B80/B84/B86 and CI items **C4–C10** as in progress, and adds **B78–B87**. A new **CI audit (2026-10-05)** section documents C1–C10 (required `CI passed`, cache keys, CodeQL/deploy/crates.io, fuzz, runners, speed, release/nightly, corpus pins, stale checks, Dependabot/zizmor) with run IDs and maintainer decisions. The **progress log** expands with session 3 evening entries (red/green runs, Measure evidence, rule slips). > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit 1eadb18. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
#528. A FamilySymbol's native record lists its connectors (m_arrConnectorData, each an m_index); its Family holds a ConnectorDataCell per connector with its domain. On RE1 Electrical, Plumbing and Mechanical every family instance Revit writes ports for has exactly its symbol's connector indices, the cable tray and conduit ones aside (Measure run 37230166352). rvt-rs wrote ports only for the joins it read.
native_connectors::symbol_port_indices reads them through the native record path (2023 to 2027), and the export gives each family instance written as a distribution element a port per connector; the writer skips one a join already gave.
Red on draft #678 (run 37230564190): Electrical 0 of 23, Plumbing 128 of 136, Mechanical 78 of 82; the output is in the test commit. Electrical's 30 proxies keep no ports: IFC4 lets a port be tied only to a distribution element.
Note
Medium Risk
Adds a native-record dependency on the IFC export path and expands port emission for MEP family instances; failures are mostly silent (no ports) but wrong connector filtering could mismatch Revit’s IFC.
Overview
B54 (#528) extends IFC export so family instances written as distribution elements get an
IfcDistributionPortfor each symbol connector Revit would export—not only connectors that appear in join records (ducts/pipes already got ports 0 and 1).A new
native_connectorsmodule readsFamilySymbol/Familynative records vianative_document::extract, maps connector indices to domains, and keeps HVAC, electrical, and piping connectors (excludes cable tray and conduit).attach_family_instance_portsruns late in the export pipeline, looks up each distribution building element’s type symbol, and pushesIfcEntity::Portrows; the STEP writer still skips ports aPortConnectionalready created. If native records cannot be read for the file release, behavior falls back to join-only ports.Docs on
IfcEntity::Portandis_distribution_element(nowpub(crate)) are updated. A corpus integration testfamily_instance_portscompares exported ports to Revit’s RE1 Electrical/Plumbing/Mechanical IFC references for distribution-entity family instances.Reviewed by Cursor Bugbot for commit 59ebdf3. Configure here.