Oct 25, 2026
…deleted branch (#1001) ## Summary Sixteen reports' reproduce commands named a branch that was deleted when it landed (`feat/mullion-span`, `feat/bare-named-parameters`, `feat/wall-extend-to-structure`, `feat/824-hatch-openings`, `re/re155-reference-slots` ... `re/re163-content-documents`, `re/878-2015-episodes`, `re/223-flag-census`, `docs/re229-symbol-lengths`), so `gh workflow run` refused them. Each now names the commit that landed (`--ref main -f ref=<sha>`, and `-f base=<parent>` where it measured a change against `main`). CONTRIBUTING's reverse-engineering steps state the rule. ## Motivation A report's reproduce section is how its counts are checked again. Measure's `ref` input takes a commit, and every probe and scorer these reports name is on `main`. ## Changes - **`reports/element-framing/RE-155` to `RE-163`, `RE-208`, `RE-219`, `RE-225` to `RE-229`**: branch refs replaced by the squash commits of #601, #606, #611, #620, #627, #628, #630, #632, #642, #928, #963, #993, #994, #996, #997 and #998. RE-224's `re/saved-mesh-status` is kept: it is the ungated branch its scorer needs, and it stays. - **`CONTRIBUTING.md`**: a report's reproduce commands name a commit, never a branch. ## Testing Unit tests are banned in this repository: do not add them. - [ ] `tools/check-local.sh`: CI. - [x] Every probe and scorer the changed commands name exists on `main` (checked file by file), and each commit is the merge of the pull request that added the report. - N/A: no code change. ## Audit-honesty checklist - [x] README / docs reflect the current state after this PR - [x] No user-visible change, so no changelog fragment - [x] Commit messages describe what changed and why - [x] No emojis in code, docs, or commit messages - [x] No private paths, personal email addresses, or internal jargon in committed files ## Legal and contribution hygiene - [x] Apache-2.0 - [x] No Autodesk proprietary content - [x] No fixtures ## Breaking changes None.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
RE-162 (B33, #528). Each of Revit's 26 IfcSystems on RE1 is one RbsHvacSystem, RbsPipingSystem or RbsElectricalSystem data object; its members are the elements whose own objects hold its id. HVAC and piping names are the object's first ASCII string; an electrical system's is its circuit number after a fixed marker and entry list, empty for Revit's circuit.
Report: reports/element-framing/RE-162-mep-systems.md. Probe: examples/probe_re162_mep_systems.rs. Measure runs 37148070432, 37148641247, 37148993751.
Note
Low Risk
Documentation and an optional example probe only; no production code paths or export logic are modified in this diff.
Overview
Adds RE-162 research artefacts: a new Measure probe and an element-framing report documenting where Revit stores MEP systems in
.rvtpartitions versus what Revit’s IFC4 exports expose asIfcSystem.The probe
probe_re162_mep_systemsparses reference IFC for each system’s name and member tags, scans inflated partitions for length-prefixed UTF-16 names and RE-153 verified data objects, and emits JSON on candidate system element ids, member overlap, system-class objects (RbsHvacSystem,RbsPipingSystem,RbsElectricalSystem), embedded strings, and id back-references. The report records a positive finding: each of the 26 RE1 systems is one system-class object whose members are elements whose own objects store that system’s id, plus naming rules (first ASCII string for HVAC/piping; circuit number after a fixed layout for electrical).This does not change export or library behavior yet; it points follow-up at writing
IfcSystemfrom those objects and a futuretests/mep_systems.rscheck against Revit.Reviewed by Cursor Bugbot for commit dada125. Configure here.