Repository navigation
feat(ifc): MEP systems as IfcSystem, grouping their members (B33, #528) - #631
Conversation
#528) Revit's IFC4 exports of the RE1 MEP models write one IfcSystem per MEP system (5 on Mechanical, 8 on Plumbing, 13 on Electrical, three of the circuits named 1), each grouping its members by IfcRelAssignsToGroup. The test requires, for each of them, an rvt-rs IfcSystem of the same name grouping the same elements among those both exports hold. Red on main before the implementation (CI run 37148704032, Corpus health tier 2, draft #629): test re1_mep_systems_are_revits ... FAILED thread 're1_mep_systems_are_revits' panicked at tests/mep_systems.rs:181:9: RE1 Mechanical: 5 of Revit's 5 systems are not rvt-rs's (name, Revit's members rvt-rs writes, the member counts of rvt-rs's unmatched systems of that name): [("OTH 3", 8, []), ("OTH 2", 2, []), ("Mechanical Return Air 1", 8, []), ("Mechanical Supply Air 1", 58, []), ("OTH 1", 2, [])] test result: FAILED. 0 passed; 1 failed; 0 ignored; 0 measured; 0 filtered out
RE-162: an MEP system is an element of its own, a data object of class RbsHvacSystem, RbsPipingSystem or RbsElectricalSystem holding its name; its members are the elements whose own data objects hold its id. On the RE1 Mechanical, Plumbing and Electrical models every one of Revit's 26 IfcSystems is one such object, and every element Revit groups in it holds the system's id. partition_mep_systems finds the system objects by class and their members among the decoded elements; partition_schema_mvp gives each member a field naming its system; the exporter writes each system as an IfcSystem with an IfcRelAssignsToGroup of its members and an IfcRelServicesBuildings to the building, as Revit's export does.
There was a problem hiding this comment.
Cursor Bugbot has reviewed your changes and found 1 potential issue.
Bugbot Autofix is ON, but it could not run because the branch was deleted or merged before autofix could start.
Comment @cursor review or bugbot run to trigger another review on this PR
Reviewed by Cursor Bugbot for commit 7ef40bd. Configure here.
| if *held != name { | ||
| *held = None; | ||
| } | ||
| } |
There was a problem hiding this comment.
Unreadable copy wipes system names
Medium Severity
A system object whose name cannot be read is stored as None, and any later copy whose name differs from that None clears the stored name. A failed parse on one partition therefore discards a valid name from another copy, so the IfcSystem is emitted unnamed even when a readable object held the name.
Reviewed by Cursor Bugbot for commit 7ef40bd. Configure here.
…odel (#35, #528) (#634) Session 2 statuses: B27, B28, B29, B30, B41 done; B33 (#631) and B39 (#630) in the queue; B40 blocked (Revit's RE1 exports write no non-Pset_ sets, Measure run 37149211122). <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Low Risk** > Documentation-only backlog and progress-log edits with no code, CI, or export behavior changes in this PR. > > **Overview** > Updates **`BACKLOG.md`** to match session 2 afternoon outcomes—no runtime or CI code in this diff. > > The session 2 ranked table moves **B27, B28, B29, B30, and B41** from “in the queue” / “in review” to **done**, marks **B33** and **B39** as **done (in the queue)**, and reclassifies **B40** from **committed** to **blocked (a model)**. > > The progress log is expanded in the same spirit: queue markers cleared for witness CI (**B27**), scorer and property-set items (**B30**, **B28**, **B41**, **B29**); **B33** now documents **`IfcSystem`** export for all 26 MEP systems (#631, RE-162, green `re1_mep_systems_are_revits`); **B39** closes the #228 “leading 3” as a negative (RE-161, #630); **B40** is blocked because RE1 Revit exports expose no non-`Pset_` reference property sets (Measure #633). **B29** notes a Bugbot fix reordering the ceiling finish check before the slab height gate. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit b3fdbd1. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
…Id 3 (#35) (#635) Marks B33 (#631) and B39 (#630) done now that they have merged, and #608 done. Corrects B39's line: RE-161 narrowed the leading 3 to ElementId 3 but did not attribute it, so #228 stays open on that element's class (RE-161 report status: narrowed; not attributed). Docs only. <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Low Risk** > Documentation-only backlog and progress-log edits with no runtime or test impact. > > **Overview** > Updates **BACKLOG.md** only to match merged work: **B33** (#631) and **#608** are marked fully **done** (removing “in the queue”), and **B39** (#630) is **done** with clarified wording. > > **B39** no longer reads as closing **#228**. RE-161 is recorded as **narrowing** the reference-list leading `3` to **ElementId 3** (internal, no name entry; not a workset or parameter value) but **not attributing** it—**#228** stays open on which element/class ElementId 3 is. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit 5d48139. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->


RE-162 (B33, #528). An MEP system is an RbsHvacSystem, RbsPipingSystem or RbsElectricalSystem data object; its members are the exported elements whose own data objects hold its id. HVAC and piping systems are named by the object's first ASCII string, electrical systems by their circuit number (Revit's where it is empty). Writes IfcSystem, IfcRelAssignsToGroup and IfcRelServicesBuildings.
Red on main: CI run 37148704032 (draft #629), RE1 Mechanical 5 of 5 systems missing.
Green: CI run 37149305337, Corpus health tier 2: test re1_mep_systems_are_revits ... ok (all 26 of Revit's systems on RE1 Mechanical, Plumbing and Electrical, same name and members); every other corpus target unchanged. The doc fix follows that run.
Note
Medium Risk
Touches IFC export and partition binary heuristics for system membership; incorrect parsing could mis-group MEP elements, but scope is additive with corpus regression tests.
Overview
Adds end-to-end MEP system export so rvt-rs can write Revit's HVAC, piping, and electrical systems as
IfcSystemgroups, matching Revit's IFC4 pattern (IfcRelAssignsToGroup+IfcRelServicesBuildings).A new
partition_mep_systemsscanner (Revit 2024+) findsRbsHvacSystem,RbsPipingSystem, andRbsElectricalSystemdata objects, derives names (ASCII string for HVAC/piping, circuit number for electrical), and infers members from elements whose payloads reference the system id.partition_schema_mvpstamps each exported element withm_mep_system_<id>fields;export_contentrolls those intoIfcEntity::Systemrecords;step_writeremits the STEP entities, skipping systems with no exported building-element members.Corpus integration test
re1_mep_systems_are_revitscompares system names and member tags against Revit's RE1 Mechanical/Plumbing/Electrical IFC exports; CI adds themep_systemstarget.Reviewed by Cursor Bugbot for commit 7ef40bd. Configure here.