Repository navigation
feat(ifc): an element's shared parameter Serial Number in Revit's SerialNumber sets (#35) - #608
Merged
Merged
Conversation
tests/serial_number.rs: on RE1 Electrical (31 elements) and Plumbing (1), every Pset_ManufacturerOccurrence and Pset_PrecastConcreteElementGeneral SerialNumber Revit writes on an element rvt-rs writes must be rvt-rs's. Red on main (draft #607, run 37142425779, Corpus health tier 2): ---- re1_serial_numbers_are_revits stdout ---- thread 're1_serial_numbers_are_revits' panicked at tests/serial_number.rs:178:9: RE1 Electrical: 50 of Revit's 50 SerialNumber values are not rvt-rs's ((tag, set), Revit's, rvt-rs's); first: [(("441149", "Pset_ManufacturerOccurrence"), "IFCIDENTIFIER('G2342')", None), (("441150", "Pset_ManufacturerOccurrence"), "IFCIDENTIFIER('G2342')", None), (("441151", "Pset_ManufacturerOccurrence"), "IFCIDENTIFIER('G2342')", None), ... test result: FAILED. 0 passed; 1 failed; 0 ignored; 0 measured; 0 filtered out; finished in 1.65s
…ialNumber sets (#35) RE-156 found SerialNumber stored as a text entry whose id is the shared parameter Serial Number's ElementId, in the element's own data object, and the parameter's definition as a data object holding its group, name and GUID. This reads it. - partition_room_parameters: find_parameter_definitions (name -> id, from the definitions' strings); scan_text_parameter, RE-153's scan for any element set and parameter id (scan_room_text_parameter now calls it). - partition_schema_mvp: m_serial_number on every element with a value. - export_content: Pset_ManufacturerOccurrence.SerialNumber (IfcIdentifier), and on a building-element proxy Pset_PrecastConcreteElementGeneral too, as Revit's RE1 Electrical and Plumbing exports write them.
DrunkOnJava
enabled auto-merge (squash)
October 3, 2026 18:07
DrunkOnJava
added a commit
that referenced
this pull request
Oct 3, 2026
Phase 0 of session 2: repository state, test inventory, the property-set gap after #603/#605/#608, RE-157's finding, and ranked items B26 to B43 with the 16 committed for this session. Also records #601 to #608 in B21's progress and corrects the B23 table's stale statuses. <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Low Risk** > Documentation-only maintainer backlog updates; no runtime, CI config, or application code changes in this diff. > > **Overview** > Updates **`BACKLOG.md`** for maintainer **session 2 (2026-10-03)**: session settings now record test policy **(a)** (leave remaining suites untouched after B23), the **ordered committed queue** (B27→B33 and related ids), and a fresh **Phase 0** snapshot (git/CI, unit-test inventory post-mirror deletion, `psets_vs_ifc` gaps, RE-157 pipe inner diameter). > > Adds a **session-2 work table** for **B26–B43** (16 items committed, B42/B43 blocked on models), extends the **B21 progress log** with **#601–#608** and reframes still-open parameter/property-set work toward the new items, logs **four session findings** (witness CI cycles/B27, duct segment quirk, etc.), and **marks B23 mirror-deletion areas** as done in **#574–#577** with Python kept under **B25**. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit 502bb34. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
DrunkOnJava
added a commit
that referenced
this pull request
Oct 3, 2026
… own export (B40, #35) (#633) B40 evidence (#35, #85). A Measure probe scorer listing every property set Revit's export relates to an object, Pset_ and other. Measure run 37149211122: Revit's RE1 exports write no property sets other than Pset_ ones (0 values on Architecture, Mechanical, Plumbing and Electrical; Pset_ values 255, 298, 612, 153). Every project or shared parameter value they carry is mapped to a standard set: SerialNumber (done, #608) and NumberOfPoles (blocked, RE-158). So B40, writing every project and shared parameter, has no reference values beyond those, and is blocked on a model whose export writes Revit's parameter-group sets. Reproduce: gh workflow run measure.yml --ref tools/b40-reference-sets -f base=none -f probe=probe_re157_pipe_inner_diameter -f probe_scorer=reference_property_sets <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Low Risk** > Adds a standalone offline research script with no changes to export, auth, or runtime paths. > > **Overview** > Adds **`tools/re/reference_property_sets.py`**, a B40 research script (#35, #85) that inspects Revit’s native IFC export via IfcOpenShell. > > It walks **`IfcRelDefinesByProperties`** links, aggregates every **`IfcPropertySet`** property by `(set name, property name)`, and prints how many values appear on how many objects, including nominal value types for single-value properties. Output splits **standard `Pset_` sets** from **Revit parameter-group sets** so Measure runs can see whether project/shared parameters show up outside standard psets. > > The CLI matches other **`tools/re`** probe scorers: **`probe.txt`** plus **`revit-export.ifc`** (the probe file is ignored); it exits with usage on bad args. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit a2c561d. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
DrunkOnJava
added a commit
that referenced
this pull request
Oct 3, 2026
…Id 3 (#35) (#635) Marks B33 (#631) and B39 (#630) done now that they have merged, and #608 done. Corrects B39's line: RE-161 narrowed the leading 3 to ElementId 3 but did not attribute it, so #228 stays open on that element's class (RE-161 report status: narrowed; not attributed). Docs only. <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Low Risk** > Documentation-only backlog and progress-log edits with no runtime or test impact. > > **Overview** > Updates **BACKLOG.md** only to match merged work: **B33** (#631) and **#608** are marked fully **done** (removing “in the queue”), and **B39** (#630) is **done** with clarified wording. > > **B39** no longer reads as closing **#228**. RE-161 is recorded as **narrowing** the reference-list leading `3` to **ElementId 3** (internal, no name entry; not a workset or parameter value) but **not attributing** it—**#228** stays open on which element/class ElementId 3 is. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit 5d48139. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
RE-156 (#606) found Revit's SerialNumber stored as a text entry whose id is the shared parameter
Serial Number's ElementId, inside the element's own data object, and the parameter's definition as a data object holding its group, name and GUID. This reads it.partition_room_parameters:find_parameter_definitions(parameter name -> ElementId, from the definitions' strings) andscan_text_parameter, RE-153's scan for any element set and parameter id;scan_room_text_parameternow calls it.partition_schema_mvp:m_serial_numberon every element with a value.export_content:Pset_ManufacturerOccurrence.SerialNumber(IfcIdentifier), and on a building-element proxyPset_PrecastConcreteElementGeneral.SerialNumbertoo, as Revit's RE1 Electrical (12 flow terminals, 19 proxies) and Plumbing (1 flow terminal) exports write them.Test:
tests/serial_number.rs(real target). Red on main: draft #607, run 37142425779, 50 of 50 values missing on RE1 Electrical; the output is in the test commit's message.Note
Medium Risk
Adds heuristic partition binary parsing and changes IFC property-set output for elements with Serial Number; export fidelity impact but no security or auth surface.
Overview
RE-156 wires Revit’s shared parameter Serial Number from partition data through to IFC export so values match Revit’s own exports.
Partition scanning is generalized:
scan_text_parameterreads any element’s text parameter by id inside its data object;find_parameter_definitionsmaps project/shared parameter names to ElementIds from definition blobs. Room floor-finish scanning now delegates to the shared helper. During MVP decode,attach_serial_numberssetsm_serial_numberon walls, columns, doors, windows, slabs, and generic products when the parameter exists.IFC export adds
serial_number_property_sets:Pset_ManufacturerOccurrence.SerialNumber(IfcIdentifier), and the same onPset_PrecastConcreteElementGeneralforIFCBUILDINGELEMENTPROXY, emitted alongside existing Reference property sets.A new
tests/serial_number.rscorpus test (RE1 Electrical/Plumbing vs reference IFC) and CIserial_numberreal target guard parity.Reviewed by Cursor Bugbot for commit 80adbc2. Configure here.