feat(ifc): a duct's size and type from its curve object, and its Length and Reference (#35, #96) - #599
Merged
Conversation
Revit's export of RE1 Mechanical gives each of its 25 rectangular ducts Pset_FlowSegmentDuctSegment.Length and Pset_FlowSegmentPipeSegment.Length (its length along its axis), and Pset_DistributionFlowElementCommon .Reference and Pset_QuantityTakeOff.Reference (its type's name). The new real-file target checks each of those on every duct rvt-rs writes with Revit's Tag: lengths within 0.1 mm, references as Revit writes them. Red on main (draft #598, run 37136951323, Corpus health tier 2): thread 're1_mechanical_duct_lengths_and_references_are_revits' panicked at tests/duct_fields.rs:224:5: 100 of the 25 ducts' Length and Reference values are not Revit's; first: ["428274 Pset_FlowSegmentDuctSegment.Length: Revit 0.2 m, rvt-rs None", ...] test result: FAILED. 0 passed; 1 failed; 0 ignored; 0 measured; 0 filtered out; finished in 0.75s
…th and Reference (#35, #96) RE-134 measured where a duct's or pipe's curve object keeps its fields: at its RbsCurveConnectorManager anchor (the nearest before its first connector entry), m_dWidthOrDiameter at +8, m_dHeight at +16 and m_idType at +64. This reads them in code. - partition_curve_fields: scan_curve_fields finds each duct's and pipe's anchor and fields; CurveFields::length_in_box gives an axis-aligned duct's length as the dimension of its record box its section leaves. - partition_schema_mvp: ducts and pipes carry m_curve_width and m_curve_height; a duct its type and that type's name (RE-130's reader) and m_duct_length. Its system family follows its shape, which is not read, so it keeps its Duct-<id> name. - export: a duct gets both flow-segment Length sets, as a pipe does, and its type's name as Reference.
DrunkOnJava
added a commit
that referenced
this pull request
Oct 3, 2026
…#597) psets_vs_ifc compared numbers at six significant figures. A pipe length rvt-rs writes a micrometre off Revit's (the writer rounds metres to six decimals) counted as different: 2 of RE1 Mechanical's and 10 of Plumbing's Lengths on #595. Numbers of the same value type are now equal within a relative 1e-5, with an absolute floor of 1e-5 in the compared unit. Measure run 37137013931, on main with #595: - RE1 Plumbing: equal 370, different 0 (was 360 and 10). Both flow-segment Lengths are equal on 63 of 63 pipes. - RE1 Mechanical: equal 110, different 0 (was 108 and 2). 6 of 6 pipes are equal; the 25 ducts are missing until #599.
…ies after it (#96) The first cut gave each curve the anchor before the first connector entry in the stream that falls in its box. A fitting's or a neighbour's entry at a shared end can come first, so 13 of RE1 Mechanical's 25 ducts found no anchor (tests/duct_fields.rs: '52 of the 25 ducts' Length and Reference values are not Revit's'). The anchors are one per curve, so each anchor now goes to the one element whose box holds the points of the first two entries after it.
DrunkOnJava
enabled auto-merge (squash)
October 3, 2026 16:42
This was referenced Oct 3, 2026
DrunkOnJava
added a commit
that referenced
this pull request
Oct 3, 2026
Records #595, #597 and #599 in B21's progress, with the property-set scores measured on main at #599's merge (Measure run 37138175399). <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Low Risk** > Documentation-only backlog update; no runtime, export, or CI logic changes in this diff. > > **Overview** > Updates **B21** (parameters milestone) in `BACKLOG.md` to reflect work merged through **#599**, not new product code. > > **#595** is recorded as done (pipe `Length` in both flow-segment sets, with `tests/segment_length.rs` and its red run). **#597** notes that the `psets_vs_ifc` Measure scorer now treats numeric properties as equal within a relative **1e-5** tolerance so tiny writer rounding no longer counts as a mismatch. **#599** documents RE-134 duct curve fields (width, height, type at the connector anchor) plus per-duct type, `Length`, and `Reference`, with `tests/duct_fields.rs` and draft **#598**’s red run. > > Adds a **Measure run 37138175399** snapshot table (equal counts per RE1 model, none “different”) and notes progress posted on **#35**, **#96**, and **#227**. The open-items list drops the duct-`Length`/RE-134 note because **#599** covers it. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit 2e023ef. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
B21, fourth slice of #35, and part of #96.
RE-134 found where a duct's or pipe's curve object keeps its fields, at its RbsCurveConnectorManager anchor: width at +8, height at +16, type id at +64. This reads them in code.
The anchors are one per curve. Each goes to the one element whose box holds the points of the first two connector entries after it. A neighbour joined at one end holds only that end. The first cut, which used the first entry in the stream, missed 13 ducts.
A duct now carries its type and that type's name. An axis-aligned duct also carries its length: the box dimension its section leaves.
It gets both flow-segment Length sets, as pipes do (feat(ifc): a pipe's Length in its flow-segment property sets (#35) #595), and its type's name as Reference (feat(ifc): the Reference of Revit's common property sets, the type's name (#35) #592).
Its system family follows its shape, which is not read, so it keeps its Duct- name.
Test (separate commit): tests/duct_fields.rs on RE1 Mechanical's 25 ducts. Red on main in draft test: red run for B21 duct fields (do not merge) #598 (run 37136951323): 100 of 100 values missing. It passes on the runners (CI run 37137543874).
Measure (run 37137540566, RE1 Mechanical, head against main)
The 2 Lengths counted as different are within 0.1 mm. This branch's scorer predates the tolerance in #597. Every other model is identical to main.