tools(re): psets_vs_ifc compares numbers within a relative 1e-5 (#35) - #597
Merged
Merged
Conversation
At six significant figures a pipe rvt-rs writes 1 um longer than Revit (the writer rounds metres to six decimals) counted as different: 2 of RE1 Mechanical's and 10 of Plumbing's pipe Lengths on #595, all within the 0.1 mm tests/segment_length.rs allows.
DrunkOnJava
added a commit
that referenced
this pull request
Oct 3, 2026
…th and Reference (#35, #96) (#599) B21, fourth slice of #35, and part of #96. RE-134 found where a duct's or pipe's curve object keeps its fields, at its RbsCurveConnectorManager anchor: width at +8, height at +16, type id at +64. This reads them in code. - The anchors are one per curve. Each goes to the one element whose box holds the points of the first two connector entries after it. A neighbour joined at one end holds only that end. The first cut, which used the first entry in the stream, missed 13 ducts. - A duct now carries its type and that type's name. An axis-aligned duct also carries its length: the box dimension its section leaves. - It gets both flow-segment Length sets, as pipes do (#595), and its type's name as Reference (#592). - Its system family follows its shape, which is not read, so it keeps its Duct-<id> name. - **Test (separate commit):** tests/duct_fields.rs on RE1 Mechanical's 25 ducts. Red on main in draft #598 (run 37136951323): 100 of 100 values missing. It passes on the runners (CI run 37137543874). **Measure** (run 37137540566, RE1 Mechanical, head against main) | | before | after | |---|---|---| | Pset_DistributionFlowElementCommon.Reference | 48 of 73 | 73 of 73 | | Pset_QuantityTakeOff.Reference | 49 of 74 | 74 of 74 | | Flow-segment Length, each set | 5 of 31 | 29 of 31 | | Type names | 49 of 74 | 74 of 74 | The 2 Lengths counted as different are within 0.1 mm. This branch's scorer predates the tolerance in #597. Every other model is identical to main.
This was referenced Oct 3, 2026
DrunkOnJava
added a commit
that referenced
this pull request
Oct 3, 2026
Records #595, #597 and #599 in B21's progress, with the property-set scores measured on main at #599's merge (Measure run 37138175399). <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Low Risk** > Documentation-only backlog update; no runtime, export, or CI logic changes in this diff. > > **Overview** > Updates **B21** (parameters milestone) in `BACKLOG.md` to reflect work merged through **#599**, not new product code. > > **#595** is recorded as done (pipe `Length` in both flow-segment sets, with `tests/segment_length.rs` and its red run). **#597** notes that the `psets_vs_ifc` Measure scorer now treats numeric properties as equal within a relative **1e-5** tolerance so tiny writer rounding no longer counts as a mismatch. **#599** documents RE-134 duct curve fields (width, height, type at the connector anchor) plus per-duct type, `Length`, and `Reference`, with `tests/duct_fields.rs` and draft **#598**’s red run. > > Adds a **Measure run 37138175399** snapshot table (equal counts per RE1 model, none “different”) and notes progress posted on **#35**, **#96**, and **#227**. The open-items list drops the duct-`Length`/RE-134 note because **#599** covers it. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit 2e023ef. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
psets_vs_ifc compared numbers at six significant figures. A pipe length rvt-rs writes a micrometre off Revit's (the writer rounds metres to six decimals) counted as different: 2 of RE1 Mechanical's and 10 of Plumbing's Lengths on #595. Numbers of the same value type are now equal within a relative 1e-5, with an absolute floor of 1e-5 in the compared unit.
Measure run 37137013931, on main with #595: