B21, second slice of #35 (RE-154, #590).

On all four RE1 models, Revit's export gives every element these Reference values, each holding the type's name:

  • Pset_QuantityTakeOff.Reference (IfcIdentifier);
  • its entity's common set's Reference (IfcIdentifier);
  • on walls and slabs, Pset_ReinforcementBarPitchOf{Wall,Slab}.Reference (IfcLabel).

No stored parameter holds the value; rvt-rs reads the type name from the partition name entries (RE-38).

Commits

  • Test: tests/common_reference.rs on the four RE1 models. Red on main in draft test: red run for B21 common References (do not merge) #591 (run 37133676030): 93 of Revit's values are missing on Architecture. The red output is in the commit message.
  • Implementation: each element named Family:Type:ElementId gets those sets. Only entities measured on the RE1 exports are listed. A door or window written as its opening (RE-84) gets none.
  • Fix: the first cut also skipped walls and slabs, whose types carry the no-geometry flag too.
  • Pinned data, with the maintainer's approval, in its own commit:
    • Core Interior step.IFCPROPERTYSET goes from 1086 to 2670.
    • The witness observations are regenerated (surface unchanged).

Measure (run 37135379188, head against main, after the Bugbot fix for the IFC4 flow, furniture and alarm subtypes)

model property sets added
Core Interior 1,584
RE1 Plumbing 246
RE1 Architecture 130
RE1 Mechanical 98
RE1 Electrical 87
Einhoven 21

Every scorer output is identical to main, and tests/common_reference.rs passes on the runners (CI run 37135701455). Because the test judges only elements both exports hold, it leaves out RE1 Plumbing's water closet tank 442378: rvt-rs exports it and Revit does not.

)

RE-154: Revit's export gives every element of the RE1 models
Pset_QuantityTakeOff.Reference and, where its entity has one, its
Pset_<Entity>Common.Reference (and on walls and slabs the reinforcement-
pitch set's), each the type's name. The new real-file target checks, on
the four RE1 models, that every element rvt-rs writes as Revit's entity
with Revit's Tag and Name carries each of those values with Revit's value
type, and that rvt-rs writes no Reference Revit does not.

Red on main (draft #591, run 37133676030, Corpus health tier 2):

    thread 're1_common_references_are_revits' panicked at
    tests/common_reference.rs:214:9:
    RE1 Architecture: 93 of Revit's Reference values on elements rvt-rs
    writes as Revit does are not in rvt-rs's export, in
    {"Pset_BuildingElementProxyCommon", "Pset_CoveringCommon",
    "Pset_CurtainWallCommon", ...}
    test result: FAILED. 0 passed; 1 failed; 0 ignored; 0 measured;
    0 filtered out; finished in 1.21s
…name (#35)

RE-154: on all four RE1 models Revit's export gives every element
Pset_QuantityTakeOff.Reference and its entity's common set's Reference
(Pset_WallCommon, Pset_DoorCommon, Pset_DistributionFlowElementCommon
and so on), and walls and slabs Pset_ReinforcementBarPitchOf{Wall,Slab}
.Reference, each the type's name, the first three as IfcIdentifier and the
last as IfcLabel. No stored parameter holds it; rvt-rs reads the type name
from the partition name entries (RE-38).

Each element named Family:Type:ElementId now gets those sets. Only the
entities measured on the RE1 exports are listed (walls, slabs, doors,
coverings, curtain walls, members, plates, railings, proxies, flow
terminals, fittings and segments, furnishing and distribution control
elements); any other gets none. A door or window written as its opening
(RE-84) gets none.

@cursor cursor Bot left a comment •

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Cursor Bugbot has reviewed your changes and found 1 potential issue.

Fix All in Cursor

Bugbot Autofix prepared a fix for the issue found in the latest run.

  • ✅ Fixed: Reference sets miss IFC4 types
    • Extended reference_property_sets match arms to include the IFC4 entity names the exporter emits so distribution, furnishing, and alarm elements receive Pset_QuantityTakeOff and Pset_DistributionFlowElementCommon Reference values.

Create PR

Or push these changes by commenting:

@cursor push bf1c81ff30
Preview (bf1c81ff30)
diff --git a/src/ifc/export_content.rs b/src/ifc/export_content.rs
--- a/src/ifc/export_content.rs
+++ b/src/ifc/export_content.rs
@@ -910,10 +910,20 @@
         "IFCPLATE" => &[("Pset_PlateCommon", true)],
         "IFCRAILING" => &[("Pset_RailingCommon", true)],
         "IFCBUILDINGELEMENTPROXY" => &[("Pset_BuildingElementProxyCommon", true)],
-        "IFCFLOWTERMINAL" | "IFCFLOWFITTING" | "IFCFLOWSEGMENT" => {
-            &[("Pset_DistributionFlowElementCommon", true)]
+        "IFCFLOWTERMINAL"
+        | "IFCFLOWFITTING"
+        | "IFCFLOWSEGMENT"
+        | "IFCDUCTSEGMENT"
+        | "IFCDUCTFITTING"
+        | "IFCPIPESEGMENT"
+        | "IFCPIPEFITTING"
+        | "IFCAIRTERMINAL"
+        | "IFCSANITARYTERMINAL"
+        | "IFCLIGHTFIXTURE"
+        | "IFCELECTRICAPPLIANCE" => &[("Pset_DistributionFlowElementCommon", true)],
+        "IFCFURNISHINGELEMENT" | "IFCFURNITURE" | "IFCDISTRIBUTIONCONTROLELEMENT" | "IFCALARM" => {
+            &[]
         }
-        "IFCFURNISHINGELEMENT" | "IFCDISTRIBUTIONCONTROLELEMENT" => &[],
         _ => return Vec::new(),
     };
     std::iter::once(("Pset_QuantityTakeOff", true))

You can send follow-ups to the cloud agent here.

Comment @cursor review or bugbot run to trigger another review on this PR

Reviewed by Cursor Bugbot for commit ddc3249. Configure here.

Comment thread src/ifc/export_content.rs Resolved
…eference sets (#35)

Walls, slabs and other system-family elements carry the type-without-
geometry flag too (their types have no geometry-material map), so the
first cut left them out: tests/common_reference.rs, 'RE1 Architecture: 65
of Revit's Reference values ... are not in rvt-rs's export', first wall
415431. RE-84's opening-only rule is for doors and windows.
…ated witness observations, for the Reference sets (#35)

With the maintainer's approval. Core Interior's 360 walls, 132 doors and
80 slabs now carry the Reference sets Revit's export writes, so
step.IFCPROPERTYSET moves 1086 -> 2670 in both project-count manifests
(project_count_fixtures: 'step.IFCPROPERTYSET: actual 2670, expected 1086
+/- 8'). The witness observations are copied from Measure run 37134311032
at 6d69e03; the surface is unchanged.
@DrunkOnJava
DrunkOnJava enabled auto-merge (squash) October 3, 2026 15:53
…pes rvt-rs writes (#35)

Bugbot: rvt-rs writes IfcDuctSegment, IfcPipeSegment, IfcAirTerminal,
IfcFurniture, IfcAlarm and so on, where Revit's export writes the
IfcFlowSegment, IfcFlowFitting, IfcFlowTerminal, IfcFurnishingElement and
IfcDistributionControlElement supertypes, so the first cut gave them no
Reference sets.
…s supertype (#35)

Bugbot: the test matched entities exactly, so the IfcDuctSegment,
IfcAirTerminal, IfcFurniture ... elements rvt-rs writes were never
compared with Revit's IfcFlowSegment, IfcFlowTerminal,
IfcFurnishingElement ... and their missing Reference sets went unseen.
…35)

RE1 Plumbing's water closet tank 442378 is in rvt-rs's export and not in
Revit's at all ('Reference values Revit's export does not hold: 442378
Pset_DistributionFlowElementCommon Water Closet Tank_M, None'). Whether
an element should be exported is the element scorers' measure; this test
is about the Reference of elements both write.
@DrunkOnJava
DrunkOnJava merged commit 436c806 into main Oct 3, 2026
23 checks passed
@DrunkOnJava
DrunkOnJava deleted the fix/b21-common-reference branch October 3, 2026 16:11
DrunkOnJava added a commit that referenced this pull request Oct 3, 2026
…th and Reference (#35, #96) (#599)

B21, fourth slice of #35, and part of #96.

RE-134 found where a duct's or pipe's curve object keeps its fields, at
its RbsCurveConnectorManager anchor: width at +8, height at +16, type id
at +64. This reads them in code.
- The anchors are one per curve. Each goes to the one element whose box
holds the points of the first two connector entries after it. A
neighbour joined at one end holds only that end. The first cut, which
used the first entry in the stream, missed 13 ducts.
- A duct now carries its type and that type's name. An axis-aligned duct
also carries its length: the box dimension its section leaves.
- It gets both flow-segment Length sets, as pipes do (#595), and its
type's name as Reference (#592).
- Its system family follows its shape, which is not read, so it keeps
its Duct-<id> name.

- **Test (separate commit):** tests/duct_fields.rs on RE1 Mechanical's
25 ducts. Red on main in draft #598 (run 37136951323): 100 of 100 values
missing. It passes on the runners (CI run 37137543874).

**Measure** (run 37137540566, RE1 Mechanical, head against main)

| | before | after |
|---|---|---|
| Pset_DistributionFlowElementCommon.Reference | 48 of 73 | 73 of 73 |
| Pset_QuantityTakeOff.Reference | 49 of 74 | 74 of 74 |
| Flow-segment Length, each set | 5 of 31 | 29 of 31 |
| Type names | 49 of 74 | 74 of 74 |

The 2 Lengths counted as different are within 0.1 mm. This branch's
scorer predates the tolerance in #597. Every other model is identical to
main.
DrunkOnJava added a commit that referenced this pull request Oct 4, 2026
…679)

BACKLOG.md: statuses for B45, B46, B54, B55, B56, B60, B64, B68, B70 and
B71; new rows B72 to B77; the afternoon's progress log (red and green
runs, Measure evidence, the B38 and B47 findings, rule notes).

CHANGELOG.md [Unreleased] stopped at #592 (B76). It now has an entry for
each user-visible change since, through #677, grouped as the file groups
them (Added, Changed, Fixed, Research).

<!-- CURSOR_SUMMARY -->
---

> [!NOTE]
> **Low Risk**
> Markdown-only updates to BACKLOG and CHANGELOG; no application, test,
or CI logic changes in this diff.
> 
> **Overview**
> **Documentation-only (B76):** brings maintainer backlog and public
release notes in line with session 3 work already merged in other PRs—no
runtime or exporter code changes.
> 
> **`BACKLOG.md`** updates the ranked table (e.g. B45–B46, B55–B56, B60,
B64, B68–B71 marked **done**; B47 **blocked** on MEP-sample evidence;
B54 **in progress** on #673). It adds backlog rows **B72–B77** (type
GlobalIds, `typed-no-geometry` gap, 2024 ordinals, changelog debt,
`--saved-meshes` gating). A new **Session 3, afternoon** progress log
records PRs, CI runs, Measure evidence, and rule notes; **Findings** are
revised (B38 phase refutation, B55 opening, B74/B77).
> 
> **`CHANGELOG.md` `[Unreleased]`** is extended from #592 through
**#676**: **Added** (wall-profile opening, native 2025/2026 + phases,
railing types, duct/pipe end ports, type GlobalIds, curtain
doors/materials, space containment, MEP systems, parameters/CLIs, etc.),
**Changed** (single export walk B71, MEP export perf B70, witness slim
step B27), **Fixed** (`--saved-meshes` scope B77, `rvt-write` B69,
diagnostics B49), and **Research** entries for RE-155–RE-168 and corpus
pins.
> 
> <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit
5f1e5fe. Configure
[here](https://www.cursor.com/dashboard/bugbot).</sup>
<!-- /CURSOR_SUMMARY -->
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant