Skip to content

docs(elements): RE-131 entries are keyed by the pipe or the element connected there, and ends match to 0.00001 ft (#96) - #523

Merged
DrunkOnJava merged 1 commit into
mainfrom
docs/re131-entry-keys
Sep 30, 2026
Merged

DrunkOnJava merged 1 commit into
mainfrom
docs/re131-entry-keys

Conversation

@DrunkOnJava

@DrunkOnJava DrunkOnJava commented Sep 30, 2026 •

Copy link
Copy Markdown
Owner

Summary

Corrects two statements in RE-131 (#522) that said more than was measured: what an entry's element is at a pipe's ends, and how closely the ends match.

Motivation

#522 said an entry is keyed by the pipe "for an end nothing is connected to" and by the connected element otherwise. Only the second half was checked: pipe 442026's two ends are keyed by 442040 and 442191, two Closet Bend fittings whose placements in Revit's IFC sit 0.1413 ft beyond the pipe's ends on its axis, each beside the end it is keyed for. Pipes 441731 and 441849 have both entries keyed by the pipe itself, and what is at those ends was not looked at. The doc comment and the note on the tolerance also said "to the last bit"; the scorer's resolution supports 0.00001 ft.

Changes

  • src/partition_pipe_axes.rs doc comments, the RE-131 report, the CHANGELOG entry and the support-matrix note now say the entry is keyed by the pipe itself or by the element connected at that end, with the 442026 evidence, and give the ends' agreement as 0.00001 ft. No code changes.

Testing

Docs and comments only. The fittings' placements are from RE1 Mechanical's own IFC (IFCFLOWFITTING Tags 442040 and 442191, placed at x = -178.7549 and -184.0042 ft against the pipe's ends at -178.8962 and -183.8629 ft, same y and z).

  • cargo fmt clean; the doc comment change is the only Rust change

Legal and contribution hygiene

Breaking changes

None.

Related issues

Refs #96.


Note

Low Risk
Comment and documentation edits only; pipe cylinder decoding behavior is unchanged.

Overview
Documentation-only correction for RE-131 (#96): pipe partition connector entries are described as keyed by the pipe itself or the connected element at that end, not as “pipe when unconnected, connected element otherwise” (only the connected case was fully verified).

The RE-131 report, CHANGELOG, support matrix, and partition_pipe_axes module docs now cite pipe 442026 (ends keyed to fittings 442040 / 442191, placements 0.1413 ft beyond the pipe axis per Revit IFC) and note 441731 / 441849 have both entries keyed by the pipe. Measured end agreement is stated as 0.00001 ft (scorer resolution) instead of “to the last bit”; the POINT_TOLERANCE_FEET comment clarifies that slack is for float noise only.

No runtime or export logic changes.

Reviewed by Cursor Bugbot for commit 611e63b. Configure here.

…onnected there, and ends match to 0.00001 ft (#96)
@cursor

cursor Bot commented Sep 30, 2026

Copy link
Copy Markdown

Bugbot couldn't run - usage limit reached

Bugbot is counted against Cursor usage for this user or team, and this run hit a usage or spend limit.

A user or team admin can review and increase usage limits in the Cursor dashboard.

(requestId: serverGenReqId_9cca1cf5-1607-4d6d-8913-617bdf75a881)

@DrunkOnJava
DrunkOnJava merged commit a7a766a into main Sep 30, 2026
21 checks passed
@DrunkOnJava
DrunkOnJava deleted the docs/re131-entry-keys branch September 30, 2026 14:01
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant