Repository navigation
docs(elements): RE-131 entries are keyed by the pipe or the element connected there, and ends match to 0.00001 ft (#96) - #523
Merged
Conversation
…onnected there, and ends match to 0.00001 ft (#96)
Bugbot couldn't run - usage limit reachedBugbot is counted against Cursor usage for this user or team, and this run hit a usage or spend limit. A user or team admin can review and increase usage limits in the Cursor dashboard. (requestId: serverGenReqId_9cca1cf5-1607-4d6d-8913-617bdf75a881) |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
Corrects two statements in RE-131 (#522) that said more than was measured: what an entry's element is at a pipe's ends, and how closely the ends match.
Motivation
#522 said an entry is keyed by the pipe "for an end nothing is connected to" and by the connected element otherwise. Only the second half was checked: pipe 442026's two ends are keyed by 442040 and 442191, two Closet Bend fittings whose placements in Revit's IFC sit 0.1413 ft beyond the pipe's ends on its axis, each beside the end it is keyed for. Pipes 441731 and 441849 have both entries keyed by the pipe itself, and what is at those ends was not looked at. The doc comment and the note on the tolerance also said "to the last bit"; the scorer's resolution supports 0.00001 ft.
Changes
src/partition_pipe_axes.rsdoc comments, the RE-131 report, the CHANGELOG entry and the support-matrix note now say the entry is keyed by the pipe itself or by the element connected at that end, with the 442026 evidence, and give the ends' agreement as 0.00001 ft. No code changes.Testing
Docs and comments only. The fittings' placements are from RE1 Mechanical's own IFC (
IFCFLOWFITTINGTags 442040 and 442191, placed at x = -178.7549 and -184.0042 ft against the pipe's ends at -178.8962 and -183.8629 ft, same y and z).cargo fmtclean; the doc comment change is the only Rust changeLegal and contribution hygiene
Breaking changes
None.
Related issues
Refs #96.
Note
Low Risk
Comment and documentation edits only; pipe cylinder decoding behavior is unchanged.
Overview
Documentation-only correction for RE-131 (#96): pipe partition connector entries are described as keyed by the pipe itself or the connected element at that end, not as “pipe when unconnected, connected element otherwise” (only the connected case was fully verified).
The RE-131 report, CHANGELOG, support matrix, and
partition_pipe_axesmodule docs now cite pipe 442026 (ends keyed to fittings 442040 / 442191, placements 0.1413 ft beyond the pipe axis per Revit IFC) and note 441731 / 441849 have both entries keyed by the pipe. Measured end agreement is stated as 0.00001 ft (scorer resolution) instead of “to the last bit”; thePOINT_TOLERANCE_FEETcomment clarifies that slack is for float noise only.No runtime or export logic changes.
Reviewed by Cursor Bugbot for commit 611e63b. Configure here.