Repository navigation
fix(ifc): full IFC4 attribute lists on every emitted instance, and storeys from element-record bboxes - #217
Merged
Conversation
…bboxes Two fixes to the IFC4 STEP writer that share the same emitted files. #214 — every emitted instance now carries the full attribute list its entity type declares. The writer stopped after IfcProduct's seven attributes plus Tag, so IFCCOLUMN / IFCSLAB / IFCWALL / IFCBEAM were one short of the schema's nine, IFCDOOR / IFCWINDOW three short of thirteen, and IFCSPACE three short of eleven. IFC4 requires an instance to list every attribute its type declares — an unknown optional occupies its slot as `$` — so these records were non-conformant, and reading PredefinedType off one raised "Index 8 is out of range for variant of size 8". 338 instances on 2024_Core_Interior.rvt, 21 across the two committed fixtures. Emission is now driven by a per-type attribute layout, and IfcEntity::BuildingElement carries a predefined_type populated from category_map, so a Column emits .COLUMN., a Floor .FLOOR., a Wall .STANDARD., a Room .INTERNAL. IFCSPACE also stops writing the type GUID into slot 8: IfcSpace is a spatial element with no Tag, so that slot is LongName. A value that is not a legal STEP enumeration name degrades to `$` rather than corrupting the record, since an enumeration reference has no escape form. The same audit surfaced three more arity defects, all fixed here: IFCISHAPEPROFILEDEF wrote 8 against IFC4's 10 (FlangeEdgeRadius, FlangeSlope), IFCCLASSIFICATIONREFERENCE 5 against 6 (Sort), and IFCMATERIALLAYERSETUSAGE 4 against 5 (ReferenceExtent). Elevation on IFCBUILDINGSTOREY was a bare integer literal where ISO-10303-21 wants a REAL. The emitted Core Interior IFC goes from 338 mismatching instances to 0 across all 33 entity types. tools/ci/ifc_schema_arity.py re-derives every entity's declared attribute count from the IFC4 EXPRESS schema and compares it with what the STEP text wrote, for every instance in a file, plus a null check on PredefinedType where category_map always supplies one. IfcOpenShell's open() accepts a short record, so the existing count-only gate could not see this class of defect. Wired into the ifcopenshell-validate job over both fixtures and the freshly emitted real-project IFC, into check-local.sh --ifcopenshell, and into validate-real-ifc.py; a Rust regression test pins the same table without needing Python. #213 — storey elevations now come from the partition element-record bounding-box distribution, and each recorded element is contained in the storey whose elevation equals its base. On 2024_Core_Interior.rvt the 256 recovered OST_Columns records stand on exactly 11 distinct base elevations (0, 31, 46, 61, 76, 91, 106, 121, 136, 151, 166 ft) and all 11 equal an IfcBuildingStorey.Elevation in Revit's own export of the same file, with no false positives; the export's other four (-40, -20, 15, 185.5 ft) carry no column record and are not claimed. IfcRelContainedInSpatialStructure goes 1 -> 11 and 256 of 338 elements land in a specific storey instead of all 338 defaulting to the first. Both halves fail closed. The storey set is replaced only when the recovered Level rows carry no elevation of their own, so the 2023 ArcWall path is untouched (Einhoven: 4 storeys, 4 containment relations, unchanged). An element whose base matches no storey, or more than one, stays unbound. Level names are deliberately not paired with the measured elevations: 12 name candidates against 11 elevations is not a pairing, and a rank join puts Level 6 at 91 ft where the export puts Level 7, so every storey is labelled "Elevation N ft" and the names stay visible in diagnostics.decoded.production_class_counts.Level. Level ElementId binding remains unsolved (#86 / RE-20) and is not what this does. storey_count moves 12 -> 11 in both project-count manifests; both rvt-rs observations were regenerated (IFCBUILDINGSTOREY 12 -> 11, IFCRELCONTAINEDINSPATIALSTRUCTURE 1 -> 11, IFCLOCALPLACEMENT 352 -> 351, IFCPROPERTYSINGLEVALUE 1536 -> 1792, storey_count 12 -> 11), so their observation_hash_sha256 changed; both committed verdicts still PASS byte-identically because entity_counts.IFCBUILDINGSTOREY is a decoder_baseline field outside the claimed surface. unsupported_geometry_missing_level drops 274 -> 18. Closes #214 Closes #213 Claude-Session: https://claude.ai/code/session_01BaHKf1Rw5aJBGK5y3xmx7C
Bugbot couldn't run - usage limit reachedBugbot is counted against Cursor usage for this user or team, and this run hit a usage or spend limit. A user or team admin can review and increase usage limits in the Cursor dashboard. (requestId: serverGenReqId_5a434650-a811-4d69-9b9e-f5f2c3ddff23) |
This was referenced Aug 30, 2026
DrunkOnJava
added a commit
that referenced
this pull request
Aug 30, 2026
…rom Revit 2024 partition element records (#211) (#221) Closes #211. Explains and closes #216. `2024_Core_Interior.rvt` (sha256 `c805df44…`) against Revit's own full-project export `IFC Exports/2024_Core_Interior_slim.ifc` (sha256 `bfdf36ff…`), whose per-entity `Tag` carries the source ElementId. ## The rule #210 established that the Revit 2024 partition element-record header reaches **100 %** of the exported ElementIds in every architectural category. What was missing was precision. Two fields inside the 54 bytes #210 recorded as "0xff sentinel padding + three unattributed words" supply it: ```text +0x32 u64 container ElementId, 0xffff_ffff_ffff_ffff = none +0x42 u32 placement kind: 0xffffef7f placed instance 0xffff8000 family/type symbol envelope ``` > A record is a standalone placed instance — what Revit's exporter emits as a > building element — **iff** `u64 @ +0x32 == 0xFFFF_FFFF_FFFF_FFFF` **and** > `u32 @ +0x42 == 0xFFFF_EF7F`. `PartitionElementRecord::is_exported_instance`. Both halves are required; neither is sufficient alone. **This is not a re-opening of RE-19.** The carrier is the element record's own `BuiltInCategory` field, not the `ArcWallRectOpening` index and not a schema-field decode. Both RE-19 negatives stand and are still reported: `schema_field_wall_instances` still fires (its check now requires a wall whose body did *not* come from an element record, so an element-record wall cannot clear it by accident), and door/window **host binding** is still unsupported. ## Set-difference evidence Prologue bytes `+0x1a..+0x50`, exported vs not exported: | side | distinct patterns | shape | |---|---:|---| | exported | 1 per category | `ff`×40 then `7fefffff` `<w46>` `<w4a>` `ffffffff` | | container members | 9 owner values | `ff`×24 then **`<owner u64>`** then `ff`×8 then `7fefffff` … | | type symbols | 2 per category | `ff`×40 then **`0080ffff`** `<w46>` `<w4a>` `ffffffff` | Rules measured independently and together (ElementId sets, not counts): | category | A: `+0x32` unset | B: `+0x42` placed | **A ∧ B** | exported | |---|---:|---:|---:|---:| | `OST_Walls` (-2000011) | 361 (1 FP) | 1209 (849 FP) | **360 exact** | 360 | | `OST_Doors` (-2000023) | 147 (15 FP) | 185 (53 FP) | **132 exact** | 132 | | `OST_Windows` (-2000014) | 8 (2 FP) | 7 (1 FP) | **6 exact** | 6 | | `OST_Columns` (-2000100) | 273 (17 FP) | 375 (119 FP) | **256 exact** | 256 | Every non-sentinel `+0x32` value is a container ElementId: all nine are declared in `Global/ElemTable`, all are lower than every member id that names them, each owns a contiguous ElementId block spanning several categories at once, and none has an element record of its own (brute scan of all 23470 decodable records finds none). | owner | columns | walls | doors | windows | member range | |---:|---:|---:|---:|---:|---| | 16229 | 23 | 66 | 14 | 1 | 16347 – 16995 | | 21984 | 24 | 8 | – | – | 22008 – 22077 | | 23117 | 24 | 57 | 11 | – | 23134 – 23733 | | 26863 | 24 | 63 | 14 | – | 26880 – 28001 | | 26908 | – | 27 | – | – | 26993 – 27045 | | 33696 | 24 | 70 | 14 | – | 33748 – 34467 | | 81029 | – | 277 | – | – | 81041 – 87363 | | 87754 | – | 4 | – | – | 87758 – 87764 | | 108205 | – | 277 | – | – | 108216 – 114538 | Full write-up, histograms and reproduction commands: [`reports/element-framing/RE-21-partition-element-record-instance-rule.md`](reports/element-framing/RE-21-partition-element-record-instance-rule.md). ## Measured before → after `cargo build --profile ci --bin rvt-ifc && ./target/ci/rvt-ifc <rvt> -o /tmp/x.ifc --diagnostics /tmp/d.json` | decoder metric | before | after | export expects | manifest status | |---|---:|---:|---:|---| | `by_ifc_type.IFCWALL` | 0 | **360** | 360 | `known_gap` → **`known`**, tol 0 | | `by_ifc_type.IFCDOOR` | 0 | **132** | 132 | `known_gap` → **`known`**, tol 0 | | `by_ifc_type.IFCWINDOW` | 0 | **6** | 6 | `known_gap` → **`known`**, tol 0 | | `by_ifc_type.IFCCOLUMN` | 256 | 256 | 256 | `known` (rule replaced) | | `by_ifc_type.IFCSLAB` | 64 | 64 | 80 | `known_gap` (#212) | | `by_ifc_type.IFCSPACE` | 18 | 18 | 116 | `known_gap` | | `exported.material_count` | 102 | 102 | 10 | `known_gap` | | `step.IFCPROPERTYSET` | 320 | **818** | 0 | `known_gap` | | `step.IFCUNITASSIGNMENT` | 1 | 1 | 1 | `known` | | `exported.storey_count` | 11 | 11 | 15 | `decoder_baseline` | | `building_elements_with_geometry` | 256 | **754** | — | — | | `exported.storey_bound_elements` | 256 | **743** of 836 | — | — | | `step.IFCRELCONTAINEDINSPATIALSTRUCTURE` | 11 | 11 | — | — | ("before" = `main` at f4b88df, i.e. after #217.) Id-set check on the emitted IFC (not just counts): ``` IFCWALL: rvt-rs=360 export=360 exact=True missing=0 extra=0 IFCDOOR: rvt-rs=132 export=132 exact=True missing=0 extra=0 IFCWINDOW: rvt-rs=6 export=6 exact=True missing=0 extra=0 IFCCOLUMN: rvt-rs=256 export=256 exact=True missing=0 extra=0 ``` ## #216 falls out The 136 `OST_Columns` ids Revit omits split with no remainder: - **17 type symbols** (`+0x42 == 0xffff8000`) — ids 5755, 19250, 22374, 24299, 28008, 53894, 75407–75417, exactly the 17 #216 lists as family-local; - **119 container members** (`+0x32` set) — the blocks 16347–16369, 22045–22068, 23134–23157, 26880–26903, 33748–33771 that #216 identified as "exact co-locations of an exported column", each owned by the id allocated just before its block. So the #204 heuristic is **retired**: `partition_schema_mvp` no longer drops origin-centred family-local bounding boxes and no longer collapses co-located footprint groups to their highest `ElementId`. It applies the direct test, reproduces the same 256/256 columns, and additionally the wall / door / window id sets — which the heuristic could not (648 / 139 / 8). `is_family_local` is kept as a documented, strictly weaker diagnostic: the `+0x42` symbol set is a superset of it on every category, catching 15 door, 2 window and 1 wall symbols whose envelope is centred on only one axis (e.g. id 17331 spans `x −1.749…1.749` but `y −0.332…3.251`). ## What did not move `OST_Floors` stays `known_gap` (#212), measured not hand-waved: 124 distinct ids carry the category, 79 of the 80 exported slabs have a record at all, and the rule selects 99 (TP 79 / FP 20 / FN 1). `+0x42` is `0xffffef7f` on all 146 floor records — there are no slab type symbols on this file — so the rule degenerates to `+0x32` alone there. That needs a slab-appropriate identity key, not a looser tolerance. No tolerance was widened anywhere in this PR. ## Storey elevations — the #213 evidence base did not widen silently #217 derives storey elevations from element-record base `z`. Adding three categories to the record set would have widened that evidence base by accident, so the restriction is now measured, against the fifteen `IfcBuildingStorey.Elevation` values in the export: | category | distinct base elevations | equal to a storey | not a storey | |---|---:|---:|---| | `OST_Columns` | 11 | 11 | — | | `OST_Doors` | 11 | 11 | — | | `OST_Walls` | 13 | 12 (adds **−40 ft**) | 56.4167 | | `OST_Windows` | 6 | **0** | 80.73, 95.73, 110.73, 125.73, 140.73, 155.73 | A window sits at its sill height above the level that hosts it, so its record base is never a storey elevation; a wall may start mid-storey. Only `IFCCOLUMN` therefore *supplies* elevations (new `ifc::STOREY_ELEVATION_SOURCE_TYPES`), which keeps #213's measured "no false positives" claim exactly as recorded and `storey_count` at 11. Every record-bodied element still *binds* by exact match, so `IfcRelContainedInSpatialStructure` stays 11 while storey-bound elements go **256 → 743 of 836**: all 256 columns, all 132 doors, 355 of 360 walls. The 5 walls at −40 / 56.4167 ft and all 6 windows stay unbound rather than being placed by proximity. **Of the four export elevations #213 could not reach (−40, −20, 15, 185.5 ft), these categories surface exactly one: −40 ft, from wall records — and taking it costs one elevation that is not a storey.** That trade is left open rather than taken. The other three carry no record of any of the four categories. ## IFC4 attribute arity (#214) `tools/ci/ifc_schema_arity.py` on a fresh Core Interior export including the new walls/doors/windows: ``` IFC schema conformance passed schema: IFC4 instances checked: 15035 across 36 entity type(s) PredefinedType populated: IfcColumn=256, IfcSlab=64, IfcWall=360 ``` ## Verdicts ``` magnetar-2024-core-interior-slim: PASS — witnesses ifc-lite, ifcopenshell, rvt-rs surface: 8 fields, excluded: 5, diffs: 0 ``` surface `IFCWALL`, `IFCDOOR`, `IFCWINDOW`, `IFCCOLUMN`, `IFCROOF`, `IFCBEAM`, `IFCFLOWTERMINAL`, `IFCUNITASSIGNMENT` (was 5 fields / 8 excluded); `verdict_hash_sha256` `afa87bb0a4e35ea8e5fa9a1adb21b29f8a0ba532571c88fd00c14dabcd4c7145`. ``` magnetar-2024-core-interior: PASS — witnesses ifc-lite, ifcopenshell, rvt-rs surface: 4 fields, excluded: 8, diffs: 0 ``` `verdict_hash_sha256` `ae4679f6044a4c3caa0b2f3a6030648bc633b1d878957a759120f011f71ded5e`. Both `rvt-rs.json` observations were regenerated **after** merging `origin/main` at f4b88df (#217), so their `observation_hash_sha256` reflects both changes: `d88897c6d9b8223350a831f4caf48d76d469a4d4f47815da56da6d34e9364fb7`. ## Diagnostics vocabulary made precise Two composite `unsupported_features` were half-true after this change, so they were split into what is actually still missing: - `typed_door_window_discrimination_and_host_binding` now fires only when no typed door or window is exported at all. When they are exported but carry no host, the narrower **`door_window_host_wall_binding`** fires instead. - New **`revit_element_parameters_to_ifc_property_sets`** fires while every exported `IfcPropertySet` is rvt-rs provenance about a recovered body rather than a Revit element parameter (#35). The two manifest rows that previously borrowed the door/window feature name now use accurate ones. - `schema_field_wall_instances` keeps firing (see above). ## Docs `docs/status.md`, `docs/support-matrix.json` (`column-instance-recovery` → `element-record-instance-recovery`, still `verified`, scope restated for four categories; `typed-door-window` and `schema-field-wall` stay `unsupported` with their honesty invariants intact), `docs/verification-protocol.md` edges table + honesty note, `docs/supported-profile.md`, `README.md` (three surgical lines), `CHANGELOG.md`, and the new RE-21 report. ## Gates run `cargo fmt --all`, `cargo clippy --profile ci --all-targets -- -D warnings`, `RUSTDOCFLAGS="-D warnings" cargo doc --no-deps`, `cargo +1.85.0 check --all-targets` (MSRV 1.85, no let-chains), `tools/check-local.sh`, and the full `cargo test --profile ci` suite with `RVT_PROJECT_CORPUS_DIR` / `RVT_CORPUS_TIER1_DIR` — all green, including every tier-2 target from #209 (`elem_table_corpus`, `arc_wall_corpus`, `partition_scanner`, `iter_elements_typed`, `re15_geometry_invariants`, `re19_door_window_wall_negative`, `walker_to_ifc_integration`) plus `witness_verdict`, `witness_registry`, `project_count_fixtures`, `support_matrix`. `tests/iter_elements_typed.rs::core_interior_2024_rect_openings_not_fake_doors` now pins the exact counts **and** asserts every recovered Wall/Door/Window carries provenance `partition_schema_mvp::element_category_record`, so the RE-19 negative is enforced by mechanism, not by a zero. ## Merge with #217 `origin/main` at f4b88df was merged into this branch before the final measurement, so every number above is post-#217. The STEP emitter and `category_map` `predefined_type` values are untouched; the hunks in `src/ifc/mod.rs` are `unsupported_export_features`, the new `STOREY_ELEVATION_SOURCE_TYPES` restriction described above, one re-export line, and one `expect` message. ## Follow-ups - #212 slab instance identity — the rule does not hold there; the record bbox is also the obvious source for the unresolved extrusion thickness. - Door/window host-wall binding (`door_window_host_wall_binding`) — the record body past `+0xa8` was dumped but not yet mined for a host reference. - `docs/octetproof-spec.md` §6's worked verdict example is a two-lineage snapshot and was already stale before this PR (the committed verdict has three lineages); refreshing a published 1.0.0 artifact is a separate call. - `+0x46` / `+0x4a` remain unattributed; their values correlate with class, which may be a schema class-id join worth a look. <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Medium Risk** > Changes core decode/IFC export and cross-witness gates for a corpus-proven Revit 2024 edge; scope is narrow but wrong instance filtering would skew real-project exports and CI verdicts. > > **Overview** > **Revit 2024 partition element records** now drive typed **Wall, Door, Window, and Column** recovery using a direct byte rule instead of the retired #204 column heuristic (family-local bbox drop + highest-`ElementId` per footprint). Records decode **container reference** at `+0x32` and **placement kind** at `+0x42`; `PartitionElementRecord::is_exported_instance` keeps only standalone placed instances. On Core Interior that matches Revit’s export **ElementId sets** at tolerance 0 (360/132/6/256), with bbox envelope geometry and shared `RvtElementRecordGeometry` property sets in IFC. > > **Production and verification** wire walls/doors/windows through `partition_schema_mvp::instances_from_partition_category_records`, unify element-record geometry in `export_content`, and narrow **storey elevation sourcing** to columns only (`STOREY_ELEVATION_SOURCE_TYPES`) while other record-bodied elements still **bind** storeys by exact base elevation (743/836 bound). OctetProof manifests move walls/doors/windows to **`known`** on the slim edge (8-field claimed surface); diagnostics split host binding vs discrimination and add `revit_element_parameters_to_ifc_property_sets`. RE-19/schema-field walls and door/window **host** binding stay explicitly unsupported; slabs (`OST_Floors`) remain #212 `known_gap`. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit cb75c37. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
DrunkOnJava
added a commit
that referenced
this pull request
Aug 30, 2026
…on PredefinedType (#236) Two conformance fixes to the IFC4 writer, both measured against Revit's own export of the same project. Corpus: `.rvt` sha256 `c805df445d613b408e37337765572021265e3f5dfdc7d1fa53b22ba1600b8014`, slim IFC sha256 `bfdf36ffb0bb768f3409d818403990e64d4c262c6780603be87f8077387ad86d`. ## #232 — every element was placed twice The writer emitted the element's own `IfcAxis2Placement3D` in **both** the `IfcLocalPlacement`'s `RelativePlacement` and the swept solid's `Position`. IFC4 has a conforming consumer compose `ObjectPlacement × Position`, so the element translation was applied twice. Viewers that ignore `Position` drew the file correctly, which is exactly why it shipped on every release: two tools could disagree about the same bytes with neither of them misreading. ### The Position decision, and the export's evidence Read with IfcOpenShell 0.8.5 on `2024_Core_Interior_slim.ifc`, Revit's own exporter is consistent about one thing — **the element translation appears exactly once** — and splits it two different ways depending on the frame the profile is authored in: | Revit entity | `ObjectPlacement.RelativePlacement.Location` | `IfcExtrudedAreaSolid.Position.Location` | |---|---|---| | `IfcWall` #2240 (`SweptSolid` body) | `(48.0, 57.667, 0.0)` | `(0.0, 0.0, 0.0)` — identity | | `IfcSlab` #1590 | `(0.0, 0.0, 0.0)` — identity | `(90.444, 71.185, -0.167)` | | `IfcSlab` #1619 | `(0.0, 0.0, 0.0)` — identity | `(93.5, 69.5, 0.0)` | | `IfcSpace` #186 | `(0.0, 0.0, 0.0)` — identity | `(51.694, 69.556, 0.0)` | Never both. Revit's walls put the location in the placement and leave `Position` at identity because the wall profile is authored in the element-local frame; its slabs and spaces do the mirror image because those profiles are authored in storey coordinates. rvt-rs authors **every** profile in the element-local frame — the rectangle always did, and the plan profile recovered in #231 uses the same frame — and it already carries the location on the element's own `IfcLocalPlacement`. So the correct half of Revit's own convention is the `IfcWall` row: **`Position` becomes the project-level identity placement**, and the placement carries the translation once. That is what this PR does. No entity is added or removed — the per-element axis is still emitted, the solid just stops pointing at it. The representation-map path is deliberately left alone, with a comment saying why: a mapped item resolves as `MappingTarget × MappingOrigin⁻¹ × geometry`, so a `Position` equal to the `MappingOrigin` cancels against the inverse instead of compounding, and `origin_feet` is `[0,0,0]` on every map rvt-rs builds today anyway. ### World-coordinate verification IfcOpenShell geometry iterator, `use-world-coords`, matched by `Tag` against the Revit export, deltas in feet. **BEFORE** | Class | shared Tags | max centroid delta | max min-vertex delta | Tags within 1e-3 ft | |---|---:|---:|---:|---:| | IfcColumn | 256 | 166.0000 ft | 166.0000 ft | 0/256 | | IfcSlab | 80 | 185.3333 ft | 185.3333 ft | 0/80 | | IfcWall | 360 | 170.2500 ft | 166.2500 ft | 0/360 | | IfcDoor | 132 | 166.0748 ft | 166.0000 ft | 0/132 | | IfcWindow | 6 | 157.1805 ft | 155.7300 ft | 0/6 | | Class | Tag | rvt-rs world centroid (ft) | Revit world centroid (ft) | delta (ft) | |---|---|---|---|---| | IfcColumn | 20375 | (48.0000, 220.0000, 159.1667) | (23.8750, 110.0000, 81.5833) | (24.1250, 110.0000, 77.5833) | | IfcColumn | 20376 | (98.0000, 220.0000, 159.1667) | (49.1250, 110.0000, 81.5833) | (48.8750, 110.0000, 77.5833) | | IfcSlab | 20311 | (181.3000, 139.0000, 151.7500) | (88.3000, 69.5000, 75.9167) | (93.0000, 69.5000, 75.8333) | | IfcSlab | 20345 | (187.0000, 139.0000, 151.7500) | (93.5000, 69.5000, 75.9167) | (93.5000, 69.5000, 75.8333) | | IfcWall | 20796 | (122.7500, 162.0000, 159.5000) | (60.1042, 81.0000, 81.7500) | (62.6458, 81.0000, 77.7500) | | IfcWall | 20797 | (96.0000, 138.7500, 159.5000) | (48.0000, 69.1667, 83.5000) | (48.0000, 69.5833, 76.0000) | | IfcDoor | 20810 | (194.0874, 118.9189, 156.1247) | (97.0437, 58.0499, 80.0499) | (97.0437, 60.8689, 76.0748) | | IfcWindow | 20898 | (65.4902, 172.2757, 165.9056) | (30.8441, 86.1378, 83.7251) | (34.6460, 86.1378, 82.1805) | The doubling reads straight off the table: the rvt-rs value is 2× Revit's wherever the element's own frame is the whole story — slab 20345 at `(187.0, 139.0)` against `(93.5, 69.5)`, column 20375 at `220.0` against `110.0`. **AFTER** | Class | shared Tags | max centroid delta | max min-vertex delta | Tags within 1e-3 ft | |---|---:|---:|---:|---:| | IfcColumn | 256 | 1.5833 ft | 0.3333 ft | 107/256 | | IfcSlab | 80 | 0.2083 ft | **0.0000 ft** | 79/80 | | IfcWall | 360 | 2.5336 ft | 0.7500 ft | 78/360 | | IfcDoor | 132 | 1.5095 ft | 3.0022 ft | 0/132 | | IfcWindow | 6 | 1.9010 ft | 0.8012 ft | 0/6 | | Class | Tag | rvt-rs world centroid (ft) | Revit world centroid (ft) | delta (ft) | |---|---|---|---|---| | IfcColumn | 20375 | (24.0000, 110.0000, 83.1667) | (23.8750, 110.0000, 81.5833) | (0.1250, -0.0000, 1.5833) | | IfcColumn | 20376 | (49.0000, 110.0000, 83.1667) | (49.1250, 110.0000, 81.5833) | (-0.1250, 0.0000, 1.5833) | | IfcSlab | 20311 | (88.3000, 69.5000, 75.9167) | (88.3000, 69.5000, 75.9167) | (-0.0000, 0.0000, 0.0000) | | IfcSlab | 20345 | (93.5000, 69.5000, 75.9167) | (93.5000, 69.5000, 75.9167) | (-0.0000, 0.0000, 0.0000) | | IfcWall | 20796 | (60.1875, 81.0000, 81.8123) | (60.1042, 81.0000, 81.7500) | (0.0833, 0.0000, 0.0623) | | IfcWall | 20797 | (48.0000, 69.3750, 83.5000) | (48.0000, 69.1667, 83.5000) | (0.0000, 0.2083, 0.0000) | | IfcDoor | 20810 | (97.0437, 59.4594, 80.1247) | (97.0437, 58.0499, 80.0499) | (-0.0000, 1.4095, 0.0748) | | IfcWindow | 20898 | (32.7451, 86.1378, 85.1756) | (30.8441, 86.1378, 83.7251) | (1.9010, -0.0000, 1.4505) | **All 80 slabs now agree with Revit's export on every world-space vertex to 0.0000 ft.** That is the class where rvt-rs recovers a real plan profile (#231), so it is the class where a placement fix can be checked at full precision, and it is exact. The residuals that remain elsewhere are **geometry recovery fidelity, not placement composition**, and each is an existing tracked gap: columns sit 0.125 ft off in plan and 1.58 ft off in Z (insertion point and base elevation), walls up to 2.53 ft on location-curve-derived bodies, and doors and windows carry the record's bounding-box envelope rather than a panel (#86, #82). None of them scales with the element's distance from the origin any more, which is the signature the doubling had. ### The gate `tools/ci/ifc_schema_arity.py` closes the class two ways, both fail-closed: 1. **Structural invariant, every file, every product** — a swept solid's `Position` may not be the very `IfcAxis2Placement3D` instance its product's `IfcLocalPlacement` already uses as `RelativePlacement`. Run against the pre-fix export it produces 992 findings, first one: `#216 IfcColumn reuses #207 as both its ObjectPlacement's RelativePlacement and its IfcExtrudedAreaSolid.Position`. 2. **Pinned composition** — for five elements the gate computes `ObjectPlacement × Position × first-profile-point` explicitly (`ifcopenshell.util.placement`, no geometry kernel) and compares against a pinned coordinate at 1e-6. Two are in `synthetic-project.ifc`, one in `synthetic-structural.ifc` and two are the recorded artifact's column `20375` and slab `20345`, so the probe fires in the fixture-only CI step *and* on the real export. A file that does not hold the Tag skips the probe rather than failing. ## #220 — PredefinedType follows the authoring witness The issue's suggested rule is adopted: where a recorded edge shows the witness's choice, take it. Agreement with the export is what the OctetProof verdicts score, and a value the witness demonstrably wrote is a recorded observation, not an invention. ### Per-type agreement, measured with IfcOpenShell | Entity | Revit's export writes | rvt-rs before | rvt-rs after | rvt-rs count | agreement | |---|---|---|---|---:|---| | IfcWall | `.NOTDEFINED.` ×360 | `.STANDARD.` | `.NOTDEFINED.` | 360 | 360/360 exact | | IfcSpace | `.SPACE.` ×116 | `.INTERNAL.` | `.SPACE.` | 18 | 18/18 exact (recall gap tracked separately) | | IfcDoor | `.DOOR.` ×132 | `$` | `.DOOR.` | 132 | 132/132 exact | | IfcWindow | `.WINDOW.` ×6 | `$` | `.WINDOW.` | 6 | 6/6 exact | | IfcColumn | `.COLUMN.` ×256 | `.COLUMN.` | `.COLUMN.` | 256 | 256/256 exact (unchanged) | | IfcSlab | `.FLOOR.` ×78, `.ROOF.` ×2 | `.FLOOR.` | `.FLOOR.` | 80 | inside the witness's value set (unchanged) | | IfcShadingDevice | `.NOTDEFINED.` ×20 | `$` | `$` | 20 | **not changed — see #235** | `Area`, `Space` and `GenericModel` keep `$`: no recorded edge shows what the witness does with those Revit classes, and inventing a value is the thing this table exists to avoid. `IfcSlab` keeps `.FLOOR.` for all 80 because splitting floors from roofs is a per-element decode, not a mapping default; the gate accepts `{FLOOR, ROOF}` for that type. `IfcShadingDevice` is the one row the witness rule reaches that this PR does not change — `category_map.rs` carries an explicit prior decision for it ("`$`, not an invented `.NOTDEFINED.`"), and flipping a written-down decision deserves its own verdict rather than riding along here. Filed as **#235**. ### No new observation surface class `PredefinedType` is an attribute value; the observation payload counts entity **type names** plus relations and storeys. Both changes are therefore invisible to the observation hash, which was confirmed rather than assumed — see below. So instead of widening the surface, the agreement check went into the arity gate as `--witness-agreement`, run on the recorded artifact in CI: ``` PredefinedType agrees with the witness: IfcColumn.COLUMN=256, IfcDoor.DOOR=132, IfcSlab.FLOOR=80, IfcSpace.SPACE=18, IfcWall.NOTDEFINED=360, IfcWindow.WINDOW=6 ``` `IfcDoor` and `IfcWindow` also joined `PREDEFINED_TYPE_REQUIRED`, since every `category_map` row for them now supplies a value. ## Observations did not move Regenerated all three witnesses on both recorded edges and diffed against the committed files: | Edge | rvt-rs | ifcopenshell | ifc-lite | verdict | |---|---|---|---|---| | `magnetar-2024-core-interior` | byte-identical | byte-identical | byte-identical | PASS, 6 fields, 0 diffs, replay match ×3 | | `magnetar-2024-core-interior-slim` | byte-identical | byte-identical | byte-identical | PASS, 13 fields, 0 diffs, replay match ×3 | **Nothing under `research/witness/` was regenerated, because nothing moved.** Entity counts, relations and storeys are unchanged. ## Fixtures Both committed fixture IFCs are regenerated with their test pins, since the writer change alters them: - `synthetic-project.ifc` — 7 `IFCEXTRUDEDAREASOLID` rows repoint from the element axis to `#14` (the project identity placement), 4 `IFCWALL` move to `.NOTDEFINED.`, the door and two windows gain `.DOOR.` / `.WINDOW.`. - `synthetic-structural.ifc` — 4 `IFCEXTRUDEDAREASOLID` rows repoint to `#14`. Its `predefined_type` values are hardcoded in the test model, not looked up, so they are untouched. `synthetic-project.ifc` also picks up a change it should have carried since #222: it was last dumped at `f4b88df` (#217), before `08f7858` gave `IfcOpeningElement` the `Tag` of the element that fills it, so its one opening still wrote `$` there. Fixtures only regenerate behind `DUMP_IFC=1`, which is how it drifted a commit behind the writer with no test noticing. Two Rust tests moved with the mappings: `lookup_known_class` now expects `.NOTDEFINED.`, and `door_and_window_have_no_predefined_type_by_default` — which asserted the old decision — is rewritten as `door_and_window_follow_the_witness_predefined_type`, with a comment recording why the old reading (type variance belongs on `IfcDoorType`) is defensible and still wrong here: Revit populates both. A new `witness_following_predefined_types` covers all five changed rows. ## Verification run | Gate | Result | |---|---| | `cargo fmt --all` | clean | | `cargo clippy --all-targets -- -D warnings` | clean | | `cargo +1.85.0 check --all-targets` | clean | | `cargo test --profile ci` × 6 named targets, corpus set | 16 passed, 0 failed | | Tier-two decoder gates (#209), 7 targets, corpus set | 40 passed, 0 failed | | `cargo test --profile ci --workspace --all-targets`, corpus set | 152 result blocks, 0 failed | | `tools/ci/ifc_schema_arity.py --witness-agreement` on a fresh export | pass — 20105 instances, 992 solids, 2 pinned probes matched | | Same gate on the pre-fix export | fails, 992 composition findings | | `tools/ci/validate-real-ifc.py` (Einhoven) | pass | | `tools/check-local.sh --ifcopenshell` | all requested gates passed | | OctetProof verdicts, both edges, `--compare-committed` | PASS, replay match on all six observations | ## Follow-ups - **#235** (filed) — `IFCSHADINGDEVICE` emits `$` where Revit writes `.NOTDEFINED.` on all 20; the #220 rule reaches it but a documented prior decision guards it. - Column Z is 1.58 ft off and plan position 0.125 ft off against the export; wall bodies up to 2.53 ft. Both are geometry recovery, now measurable for the first time because the placement no longer swamps them. - Revit splits 80 slabs into 78 `.FLOOR.` + 2 `.ROOF.`; rvt-rs writes `.FLOOR.` for all 80. Closes #232 Closes #220 https://claude.ai/code/session_01BaHKf1Rw5aJBGK5y3xmx7C <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Medium Risk** > Changes core IFC geometry placement and attribute emission for all extruded products; mitigated by new fail-closed CI gates and unchanged OctetProof observation hashes per the PR description. > > **Overview** > Fixes two IFC4 writer conformance issues measured against Revit's export of the 2024 Core Interior project. > > **Placement (#232).** Swept solids no longer reuse the element's `IfcAxis2Placement3D` as both `IfcLocalPlacement.RelativePlacement` and `IfcExtrudedAreaSolid.Position`. Translation lives only on the local placement; solid `Position` is the project identity frame so `ObjectPlacement × Position` is not applied twice. The same rule applies to extrusions, openings, and the generic `emit_solid_shape` path (mapped-item geometry is documented as a separate composition case). > > **PredefinedType (#220).** `category_map` now emits witness-aligned values where a recorded edge exists: walls `.NOTDEFINED.`, rooms `.SPACE.`, doors `.DOOR.`, windows `.WINDOW.` (replacing `.STANDARD.`, `.INTERNAL.`, and `$`). Tests and docs/compatibility tables are updated accordingly. > > **CI and gates.** `tools/ci/ifc_schema_arity.py` adds placement-composition checks on every file (no shared placement instance; pinned Tag probes) and optional `--witness-agreement` for the real-project export in CI. Synthetic IFC fixtures are regenerated (solid positions, enum values, opening `Tag` catch-up from #222). > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit 1e78616. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
DrunkOnJava
added a commit
that referenced
this pull request
Aug 31, 2026
Adds `ParameterValueSource` enum distinguishing the three kinds
of parameter-value sources Revit supports:
- UserSet (default): user types / picks; writable.
- Calculated: formula-driven. Revit recomputes from a formula
string ("= 2 * Height + Width") on every input change. Not
user-editable.
- Reporting: value pulled from geometry / element properties at
read time (e.g., Dimension reporting its length). Not user-
editable.
`ParameterElement` gains `value_source: Option<ParameterValueSource>`.
`from_decoded` reads `m_is_calculated` / `m_is_formula` /
`m_is_reporting` flags (all three aliases accepted — different
schema versions use slightly different field names). Precedence
when both flags are set: reporting > calculated > user-set
(reporting is the stronger read-only constraint; calculated can
coexist with formula-evaluated writes, but reporting never
writes).
New helper `is_user_writable()` returns `true` for UserSet or
missing flags (safe default), `false` for calculated / reporting.
6 new tests covering:
- flags-absent → None / writable
- calculated=true, reporting=false → Calculated / not-writable
- reporting=true → Reporting / not-writable
- both flags true → Reporting wins (stronger constraint)
- both flags false → UserSet / writable
- `m_is_formula` alias accepted alongside `m_is_calculated`
374 lib tests pass (was 368, +6). Closes L5B-56 (#217).
DrunkOnJava
added a commit
that referenced
this pull request
Aug 31, 2026
…oreys from element-record bboxes (#217) Two IFC4 writer fixes that share the same emitted files, so they are measured together. ## #214 — every emitted instance now carries the full IFC4 attribute list The writer emitted building elements with `IfcProduct`'s seven attributes plus `Tag` and stopped. IFC4 requires an instance to list **every** attribute its entity type declares — an unknown optional occupies its slot as `$`, it is not dropped — so those records were non-conformant, and reading the attribute raised: ``` >>> c.PredefinedType RuntimeError: Index 8 is out of range for variant of size 8 ``` `IfcEntity::BuildingElement` now carries a `predefined_type` populated from `category_map`, and emission is driven by a per-type attribute layout table. ### Attribute arity, before → after Measured with IfcOpenShell 0.8.5 by counting top-level attributes in the STEP text and comparing with `schema_by_name("IFC4").declaration_by_name(<name>).attribute_count()`. **`2024_Core_Interior.rvt`** (sha256 `c805df44…`), emitted by `rvt-ifc`: | Entity | written before | written after | IFC4 declares | instances | |---|---:|---:|---:|---:| | `IFCCOLUMN` | 8 | **9** | 9 | 256 | | `IFCSLAB` | 8 | **9** | 9 | 64 | | `IFCSPACE` | 8 | **11** | 11 | 18 | Mismatching instances on that file: **338 → 0**, across all 33 emitted entity types. **`tests/fixtures/synthetic-project.ifc`**: | Entity | before | after | declares | instances | |---|---:|---:|---:|---:| | `IFCWALL` | 8 | **9** | 9 | 4 | | `IFCSLAB` | 8 | **9** | 9 | 1 | | `IFCSTAIR` | 8 | **9** | 9 | 1 | | `IFCBUILDINGELEMENTPROXY` | 8 | **9** | 9 | 1 | | `IFCDOOR` | 10 | **13** | 13 | 1 | | `IFCWINDOW` | 10 | **13** | 13 | 2 | 10 → 0 mismatching. **`tests/fixtures/synthetic-structural.ifc`**: | Entity | before | after | declares | instances | |---|---:|---:|---:|---:| | `IFCCOLUMN` | 8 | **9** | 9 | 2 | | `IFCBEAM` | 8 | **9** | 9 | 2 | | `IFCFURNITURE` | 8 | **9** | 9 | 1 | | `IFCDOOR` | 10 | **13** | 13 | 3 | | `IFCISHAPEPROFILEDEF` | 8 | **10** | 10 | 3 | 11 → 0 mismatching. Three further arity defects the same audit surfaced, not exercised by the files above but fixed at the emission site: | Entity | before | after | declares | missing attribute(s) | |---|---:|---:|---:|---| | `IFCISHAPEPROFILEDEF` | 8 | **10** | 10 | `FlangeEdgeRadius`, `FlangeSlope` (IFC4 additions over IFC2X3) | | `IFCCLASSIFICATIONREFERENCE` | 5 | **6** | 6 | `Sort` | | `IFCMATERIALLAYERSETUSAGE` | 4 | **5** | 5 | `ReferenceExtent` | Plus `IfcBuildingStorey.Elevation`, which was written as a bare integer literal (`…,.ELEMENT.,0);`) where ISO-10303-21 requires a REAL — now `0.000000`. ### PredefinedType values `category_map` already held them; they are now written. Cross-checked against Revit's own export of the same file: | Revit class | rvt-rs emits | Revit's export emits | |---|---|---| | `Column` / `StructuralColumn` | `.COLUMN.` | `.COLUMN.` (256/256) | | `Floor` | `.FLOOR.` | `.FLOOR.` (78/80; 2 are `.ROOF.`) | | `Wall` / `ArcWall` | `.STANDARD.` | `.NOTDEFINED.` | | `Room` | `.INTERNAL.` | `.SPACE.` | Where `category_map` has no value the slot is written as `$` — the writer never invents an enum token. Two related changes fell out: - **`IFCSPACE` slot 8 is `LongName`, not `Tag`.** `IfcSpace` is an `IfcSpatialStructureElement` and declares no `Tag` at all, so the type GUID the writer used to put there was in the wrong slot. It now carries the element name, with `CompositionType = .ELEMENT.` matching Revit's export. - **A hostile `PredefinedType` degrades to `$`.** A STEP enumeration reference is written bare between dots and has no escape form, so a value with a quote or a dot in it would corrupt the record; `tests/fuzz_regressions.rs` drives adversarial names through the path. ### Making the gap impossible to reintroduce `tools/ci/ifc_schema_arity.py` re-derives every entity's declared attribute count from the IFC4 EXPRESS schema and compares it with the count actually written, **for every instance in the file**, plus a null check on `PredefinedType` for the entity types where every `category_map` row supplies one (`IfcBeam`, `IfcColumn`, `IfcCovering`, `IfcMember`, `IfcSlab`, `IfcWall`). This is the check that was missing: IfcOpenShell's `open()` happily parses a short record, so the existing count-only gate never saw the defect. Wired into three places: - the `ifcopenshell-validate` CI job, over both committed fixtures **and** the freshly emitted real-project IFC; - `tools/ci/validate-real-ifc.py`, so the existing real-project gate covers it too; - `tools/check-local.sh --ifcopenshell`. Plus Rust-side tests that need no Python toolchain: a table of the 28 emitted entity types with their schema-declared arity, asserted against both the writer's layout table and the emitted text; a sweep proving every `category_map` row resolves to a covered type; slot-position assertions for `PredefinedType`; and the hostile-token test. ### Local validation output ``` $ python tools/ci/ifc_schema_arity.py tests/fixtures/synthetic-project.ifc tests/fixtures/synthetic-structural.ifc IFC schema conformance passed: tests/fixtures/synthetic-project.ifc schema: IFC4 instances checked: 147 across 42 entity type(s) PredefinedType populated: IfcSlab=1, IfcWall=4 IFC schema conformance passed: tests/fixtures/synthetic-structural.ifc schema: IFC4 instances checked: 149 across 42 entity type(s) PredefinedType populated: IfcBeam=2, IfcColumn=2 $ python tools/ci/ifc_schema_arity.py core-interior.rvt-rs.ifc IFC schema conformance passed: core-interior.rvt-rs.ifc schema: IFC4 instances checked: 5584 across 33 entity type(s) PredefinedType populated: IfcColumn=256, IfcSlab=64 $ python tools/ci/validate-real-ifc.py walker-real-project.ifc walker-real-project.diagnostics.json Real-project IfcOpenShell validation passed: schema: IFC4 entities: 725 schema arity: 725 instance(s) across 33 entity type(s) match their declared attribute count PredefinedType populated: IfcSlab=13, IfcWall=24 exported.by_ifc_type: {'IFCSLAB': 13, 'IFCSPACE': 14, 'IFCWALL': 24} spatial containment: 4 rel(s), 51 related element(s) across 4 storey(s) geometry-backed elements: 24 material count: 42 unit assignments: 6 ``` Both committed fixtures were regenerated. Entity **text** changes; entity **counts** do not. ## #213 — storey elevations from the element-record bbox distribution, then bind `src/element_record_storeys.rs` turns the distinct base `z` of the partition element records into building storeys, and `ifc::apply_element_record_storeys` contains each recorded element in the storey whose elevation equals its base. ### Storey measurements on `2024_Core_Interior.rvt` Reference is `IFC Exports/2024_Core_Interior_slim.ifc` (sha256 `bfdf36ff…`), read with IfcOpenShell 0.8.5. That file's length unit is `FOOT` (`IfcConversionBasedUnit … 'FOOT'`), so its `Elevation` values are feet; rvt-rs writes metres and is converted for the comparison. ``` reference (ft): [-40.0, -20.0, 0.0, 15.0, 31.0, 46.0, 61.0, 76.0, 91.0, 106.0, 121.0, 136.0, 151.0, 166.0, 185.5] rvt-rs (ft): [0.0, 31.0, 46.0, 61.0, 76.0, 91.0, 106.0, 121.0, 136.0, 151.0, 166.0] exact matches: 11/11 emitted, 11/15 of the export missed by rvt-rs: [-40.0, -20.0, 15.0, 185.5] rvt-rs only : [] ``` | | before | after | |---|---:|---:| | `diagnostics.exported.storey_count` | 12 | **11** | | storey elevations matching the export exactly | 1 of 12 (`0.0`, by accident) | **11 of 11** | | false-positive elevations | 11 | **0** | | export storeys recovered | 1 of 15 | **11 of 15** | | `IFCRELCONTAINEDINSPATIALSTRUCTURE` | 1 | **11** | | elements in a specific storey | 0 of 338 (all defaulted to storey[0]) | **256 of 338** | | `unsupported_geometry_missing_level` | 274 | **18** | Column distribution across the recovered storeys (24/24/24/24/23/23/23/23/23/23/22 = 256): ``` 0.0000 ft 24 columns 91.0000 ft 23 columns 31.0000 ft 24 columns 106.0000 ft 23 columns 46.0000 ft 24 columns 121.0000 ft 23 columns 61.0000 ft 24 columns 136.0000 ft 23 columns 76.0000 ft 23 columns 151.0000 ft 23 columns 166.0000 ft 22 columns ``` The remaining 82 unbound elements are the 64 plan-loop `IFCSLAB` boundary annotations and 18 name-only `IFCSPACE` rows, neither of which carries a record bbox — they keep `storey_index: None` and fall to the writer's default container, which is the honest state. **Note on #213's premise:** the issue predicted ten distinct base elevations; the measurement on the recovered record set is **eleven**, with 166 ft (the export's `Level 12`) the additional one. ### What is not claimed Storey **names** are not recovered with the elevations, and this is a measured refusal rather than an omission. There are 12 recovered Level-like name candidates against 11 measured elevations, so the fail-closed rule the ArcWall path already uses (transfer names only when the counts match) does not fire — and checking a rank join against the reference confirms it would be wrong: it puts `Level 6` at 91 ft where the export puts `Level 7`. Every storey is therefore labelled `Elevation N ft`, the 12 names stay visible in `diagnostics.decoded.production_class_counts.Level`, and a diagnostics warning states the situation: ``` 11 building storey elevation(s) were measured from partition element-record bounding boxes and 256 building element(s) bound to them by base elevation (#213); the 12 recovered Level name string(s) could not be paired with those elevations and are not asserted as storey names. ``` Level **ElementId** binding stays unsolved — #86 / RE-20 is untouched, `LevelBindResolved` stays `false`, and elements bound by elevation additionally carry `StoreyBindSource = record_base_elevation` so the two joins can never be confused. ### Fail-closed on both halves - The storey set is replaced **only** when the recovered `Level` rows carry no elevation of their own (all at one value) and at least two distinct elevations were measured. The 2023 ArcWall path, which already recovers real elevations, is untouched — verified on the Einhoven sample: 4 storeys, 4 containment relations, byte-identical behaviour. - The join is elevation equality within 1e-3 ft and returns `None` both on a miss **and** on an ambiguity (two storeys inside the window). - Representative elevations are quantised to 1e-4 ft (0.03 mm), because bbox arithmetic leaves the `Level 1` base at `-1.9e-14` ft rather than `0.0`. ### Diagnostics New: `exported.storey_elevations_feet` (aligned with the existing `storey_names`; an all-zero list is the honest signal that only name strings were recovered) and `exported.storey_bound_elements`. Documented in `docs/export-diagnostics.md` under a new **Storey provenance** section. ## Witness observations and verdicts The #214 change alters entity **text**, not counts, so it needed no regeneration on its own. The #213 change does move counts, so both `rvt-rs.json` observations were regenerated per `docs/verification-protocol.md` § OctetProof alignment: | field | before | after | |---|---:|---:| | `IFCBUILDINGSTOREY` | 12 | 11 | | `IFCRELCONTAINEDINSPATIALSTRUCTURE` | 1 | 11 | | `IFCLOCALPLACEMENT` | 352 | 351 | | `IFCPROPERTYSINGLEVALUE` | 1536 | 1792 | | `storey_count` | 12 | 11 | `observation_hash_sha256` for both artifacts: `8f2282bc280c2c103dd54fa7fe6e20dae71811598064871b790e033676ae62be` → `b1ae3c34ebf7b6261c11d65b67af240e1c398ac046f4e8838ca3a356080181d8`. The two bridge observations (IfcOpenShell, IFClite) read the reference IFC and are unchanged. Both committed verdicts re-ran and are **byte-identical** — still `PASS`, three lineages, 0 diffs — because `entity_counts.IFCBUILDINGSTOREY` is a `decoder_baseline` field and sits outside the claimed surface: ``` magnetar-2024-core-interior: PASS — witnesses ifc-lite, ifcopenshell, rvt-rs surface: 7 fields, excluded: 5, diffs: 0 replay ifc-lite: match / replay ifcopenshell: match / replay rvt-rs: match magnetar-2024-core-interior-slim: PASS — witnesses ifc-lite, ifcopenshell, rvt-rs surface: 5 fields, excluded: 8, diffs: 0 replay ifc-lite: match / replay ifcopenshell: match / replay rvt-rs: match ``` ## Docs and manifests - `levels.decoder_expected` 12 → 11 in both project-count manifests, tolerance 0, with the measurement recorded in the notes. - New `record-elevation-storey-bind` row in `docs/support-matrix.json` (`verified`, scope stated: elevations only, Revit 2024, one decoded category). `level-elementid-storey-bind` stays `unsupported`. - `docs/status.md` storey paragraph and the IFC4-writer capability row; `docs/export-diagnostics.md` field table + Storey provenance section; `CHANGELOG.md` under Added / Changed / Fixed. ## Gate `cargo fmt --all` · `cargo clippy --all-targets -- -D warnings` · `cargo +1.85.0 check --all-targets` (MSRV, no let-chains) · `cargo test --profile ci` with `RVT_PROJECT_CORPUS_DIR` set, including `--test ifc_roundtrip --test ifc_synthetic_project --test ifc_synthetic_structural --test project_count_fixtures --test witness_verdict` · `tools/check-local.sh --ifcopenshell` — all green (916 lib tests). ## Lane note `src/ifc/export_content.rs` carries a deliberately minimal two-line hunk (`predefined_type: mapping.predefined_type.map(str::to_string)` at the one construction site, plus the same field in one test literal) — the wall/door/window lane owns that file. `src/partition_schema_mvp.rs` is untouched: the #213 join reads the record base elevation back off the emitted element via its `BodySource` property, so nothing in the recovery path had to change, and a round-trip test pins that coupling. Closes #214 Closes #213 https://claude.ai/code/session_01BaHKf1Rw5aJBGK5y3xmx7C <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Medium Risk** > Changes core IFC export (STEP writer and spatial containment) and shifts real-project diagnostics/witness hashes, but behavior is heavily regression-tested and gated by schema-arity CI. > > **Overview** > This PR fixes **IFC4 STEP conformance** (#214) and **measured storey containment** on Revit 2024 Core Interior (#213), with regenerated fixtures, witness observations, and new CI gates. > > **#214 — writer emits every declared attribute.** Building elements were one or more attributes short (e.g. `IFCCOLUMN` at 8 vs 9), which broke `PredefinedType` reads in strict consumers. `step_writer` now uses per-type tail layouts, fills unknown optionals with `$`, maps `predefined_type` from `category_map`, fixes `IFCSPACE` (`LongName` vs `Tag`), and patches arity on `IFCISHAPEPROFILEDEF`, `IFCCLASSIFICATIONREFERENCE`, and `IFCMATERIALLAYERSETUSAGE`. Storey elevations are emitted as REAL literals. Hostile enum tokens degrade to `$`. **`tools/ci/ifc_schema_arity.py`** compares EXPRESS-declared arity (and required `PredefinedType`) against every STEP instance; it runs in CI, `validate-real-ifc.py`, and `check-local.sh --ifcopenshell`, with matching Rust arity tests. > > **#213 — storeys from partition element-record base `z`.** New `element_record_storeys` derives distinct bbox elevations into `IfcBuildingStorey` rows when existing levels have no elevation evidence, then binds record-sourced columns by exact elevation (fail-closed on miss/ambiguity). Core Interior goes **12 → 11** storeys (measured vs name-only), **1 → 11** `IfcRelContainedInSpatialStructure`, **256** elements storey-bound; names stay `Elevation N ft` when 12 Level strings cannot pair with 11 elevations. Diagnostics add `storey_elevations_feet` and `storey_bound_elements`. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit db39abf401a2e901e3d9f6ee2fe68f33eb84fa26. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
DrunkOnJava
added a commit
that referenced
this pull request
Aug 31, 2026
…rom Revit 2024 partition element records (#211) (#221) Closes #211. Explains and closes #216. `2024_Core_Interior.rvt` (sha256 `c805df44…`) against Revit's own full-project export `IFC Exports/2024_Core_Interior_slim.ifc` (sha256 `bfdf36ff…`), whose per-entity `Tag` carries the source ElementId. ## The rule #210 established that the Revit 2024 partition element-record header reaches **100 %** of the exported ElementIds in every architectural category. What was missing was precision. Two fields inside the 54 bytes #210 recorded as "0xff sentinel padding + three unattributed words" supply it: ```text +0x32 u64 container ElementId, 0xffff_ffff_ffff_ffff = none +0x42 u32 placement kind: 0xffffef7f placed instance 0xffff8000 family/type symbol envelope ``` > A record is a standalone placed instance — what Revit's exporter emits as a > building element — **iff** `u64 @ +0x32 == 0xFFFF_FFFF_FFFF_FFFF` **and** > `u32 @ +0x42 == 0xFFFF_EF7F`. `PartitionElementRecord::is_exported_instance`. Both halves are required; neither is sufficient alone. **This is not a re-opening of RE-19.** The carrier is the element record's own `BuiltInCategory` field, not the `ArcWallRectOpening` index and not a schema-field decode. Both RE-19 negatives stand and are still reported: `schema_field_wall_instances` still fires (its check now requires a wall whose body did *not* come from an element record, so an element-record wall cannot clear it by accident), and door/window **host binding** is still unsupported. ## Set-difference evidence Prologue bytes `+0x1a..+0x50`, exported vs not exported: | side | distinct patterns | shape | |---|---:|---| | exported | 1 per category | `ff`×40 then `7fefffff` `<w46>` `<w4a>` `ffffffff` | | container members | 9 owner values | `ff`×24 then **`<owner u64>`** then `ff`×8 then `7fefffff` … | | type symbols | 2 per category | `ff`×40 then **`0080ffff`** `<w46>` `<w4a>` `ffffffff` | Rules measured independently and together (ElementId sets, not counts): | category | A: `+0x32` unset | B: `+0x42` placed | **A ∧ B** | exported | |---|---:|---:|---:|---:| | `OST_Walls` (-2000011) | 361 (1 FP) | 1209 (849 FP) | **360 exact** | 360 | | `OST_Doors` (-2000023) | 147 (15 FP) | 185 (53 FP) | **132 exact** | 132 | | `OST_Windows` (-2000014) | 8 (2 FP) | 7 (1 FP) | **6 exact** | 6 | | `OST_Columns` (-2000100) | 273 (17 FP) | 375 (119 FP) | **256 exact** | 256 | Every non-sentinel `+0x32` value is a container ElementId: all nine are declared in `Global/ElemTable`, all are lower than every member id that names them, each owns a contiguous ElementId block spanning several categories at once, and none has an element record of its own (brute scan of all 23470 decodable records finds none). | owner | columns | walls | doors | windows | member range | |---:|---:|---:|---:|---:|---| | 16229 | 23 | 66 | 14 | 1 | 16347 – 16995 | | 21984 | 24 | 8 | – | – | 22008 – 22077 | | 23117 | 24 | 57 | 11 | – | 23134 – 23733 | | 26863 | 24 | 63 | 14 | – | 26880 – 28001 | | 26908 | – | 27 | – | – | 26993 – 27045 | | 33696 | 24 | 70 | 14 | – | 33748 – 34467 | | 81029 | – | 277 | – | – | 81041 – 87363 | | 87754 | – | 4 | – | – | 87758 – 87764 | | 108205 | – | 277 | – | – | 108216 – 114538 | Full write-up, histograms and reproduction commands: [`reports/element-framing/RE-21-partition-element-record-instance-rule.md`](reports/element-framing/RE-21-partition-element-record-instance-rule.md). ## Measured before → after `cargo build --profile ci --bin rvt-ifc && ./target/ci/rvt-ifc <rvt> -o /tmp/x.ifc --diagnostics /tmp/d.json` | decoder metric | before | after | export expects | manifest status | |---|---:|---:|---:|---| | `by_ifc_type.IFCWALL` | 0 | **360** | 360 | `known_gap` → **`known`**, tol 0 | | `by_ifc_type.IFCDOOR` | 0 | **132** | 132 | `known_gap` → **`known`**, tol 0 | | `by_ifc_type.IFCWINDOW` | 0 | **6** | 6 | `known_gap` → **`known`**, tol 0 | | `by_ifc_type.IFCCOLUMN` | 256 | 256 | 256 | `known` (rule replaced) | | `by_ifc_type.IFCSLAB` | 64 | 64 | 80 | `known_gap` (#212) | | `by_ifc_type.IFCSPACE` | 18 | 18 | 116 | `known_gap` | | `exported.material_count` | 102 | 102 | 10 | `known_gap` | | `step.IFCPROPERTYSET` | 320 | **818** | 0 | `known_gap` | | `step.IFCUNITASSIGNMENT` | 1 | 1 | 1 | `known` | | `exported.storey_count` | 11 | 11 | 15 | `decoder_baseline` | | `building_elements_with_geometry` | 256 | **754** | — | — | | `exported.storey_bound_elements` | 256 | **743** of 836 | — | — | | `step.IFCRELCONTAINEDINSPATIALSTRUCTURE` | 11 | 11 | — | — | ("before" = `main` at 55491d7, i.e. after #217.) Id-set check on the emitted IFC (not just counts): ``` IFCWALL: rvt-rs=360 export=360 exact=True missing=0 extra=0 IFCDOOR: rvt-rs=132 export=132 exact=True missing=0 extra=0 IFCWINDOW: rvt-rs=6 export=6 exact=True missing=0 extra=0 IFCCOLUMN: rvt-rs=256 export=256 exact=True missing=0 extra=0 ``` ## #216 falls out The 136 `OST_Columns` ids Revit omits split with no remainder: - **17 type symbols** (`+0x42 == 0xffff8000`) — ids 5755, 19250, 22374, 24299, 28008, 53894, 75407–75417, exactly the 17 #216 lists as family-local; - **119 container members** (`+0x32` set) — the blocks 16347–16369, 22045–22068, 23134–23157, 26880–26903, 33748–33771 that #216 identified as "exact co-locations of an exported column", each owned by the id allocated just before its block. So the #204 heuristic is **retired**: `partition_schema_mvp` no longer drops origin-centred family-local bounding boxes and no longer collapses co-located footprint groups to their highest `ElementId`. It applies the direct test, reproduces the same 256/256 columns, and additionally the wall / door / window id sets — which the heuristic could not (648 / 139 / 8). `is_family_local` is kept as a documented, strictly weaker diagnostic: the `+0x42` symbol set is a superset of it on every category, catching 15 door, 2 window and 1 wall symbols whose envelope is centred on only one axis (e.g. id 17331 spans `x −1.749…1.749` but `y −0.332…3.251`). ## What did not move `OST_Floors` stays `known_gap` (#212), measured not hand-waved: 124 distinct ids carry the category, 79 of the 80 exported slabs have a record at all, and the rule selects 99 (TP 79 / FP 20 / FN 1). `+0x42` is `0xffffef7f` on all 146 floor records — there are no slab type symbols on this file — so the rule degenerates to `+0x32` alone there. That needs a slab-appropriate identity key, not a looser tolerance. No tolerance was widened anywhere in this PR. ## Storey elevations — the #213 evidence base did not widen silently #217 derives storey elevations from element-record base `z`. Adding three categories to the record set would have widened that evidence base by accident, so the restriction is now measured, against the fifteen `IfcBuildingStorey.Elevation` values in the export: | category | distinct base elevations | equal to a storey | not a storey | |---|---:|---:|---| | `OST_Columns` | 11 | 11 | — | | `OST_Doors` | 11 | 11 | — | | `OST_Walls` | 13 | 12 (adds **−40 ft**) | 56.4167 | | `OST_Windows` | 6 | **0** | 80.73, 95.73, 110.73, 125.73, 140.73, 155.73 | A window sits at its sill height above the level that hosts it, so its record base is never a storey elevation; a wall may start mid-storey. Only `IFCCOLUMN` therefore *supplies* elevations (new `ifc::STOREY_ELEVATION_SOURCE_TYPES`), which keeps #213's measured "no false positives" claim exactly as recorded and `storey_count` at 11. Every record-bodied element still *binds* by exact match, so `IfcRelContainedInSpatialStructure` stays 11 while storey-bound elements go **256 → 743 of 836**: all 256 columns, all 132 doors, 355 of 360 walls. The 5 walls at −40 / 56.4167 ft and all 6 windows stay unbound rather than being placed by proximity. **Of the four export elevations #213 could not reach (−40, −20, 15, 185.5 ft), these categories surface exactly one: −40 ft, from wall records — and taking it costs one elevation that is not a storey.** That trade is left open rather than taken. The other three carry no record of any of the four categories. ## IFC4 attribute arity (#214) `tools/ci/ifc_schema_arity.py` on a fresh Core Interior export including the new walls/doors/windows: ``` IFC schema conformance passed schema: IFC4 instances checked: 15035 across 36 entity type(s) PredefinedType populated: IfcColumn=256, IfcSlab=64, IfcWall=360 ``` ## Verdicts ``` magnetar-2024-core-interior-slim: PASS — witnesses ifc-lite, ifcopenshell, rvt-rs surface: 8 fields, excluded: 5, diffs: 0 ``` surface `IFCWALL`, `IFCDOOR`, `IFCWINDOW`, `IFCCOLUMN`, `IFCROOF`, `IFCBEAM`, `IFCFLOWTERMINAL`, `IFCUNITASSIGNMENT` (was 5 fields / 8 excluded); `verdict_hash_sha256` `afa87bb0a4e35ea8e5fa9a1adb21b29f8a0ba532571c88fd00c14dabcd4c7145`. ``` magnetar-2024-core-interior: PASS — witnesses ifc-lite, ifcopenshell, rvt-rs surface: 4 fields, excluded: 8, diffs: 0 ``` `verdict_hash_sha256` `ae4679f6044a4c3caa0b2f3a6030648bc633b1d878957a759120f011f71ded5e`. Both `rvt-rs.json` observations were regenerated **after** merging `origin/main` at 55491d7 (#217), so their `observation_hash_sha256` reflects both changes: `d88897c6d9b8223350a831f4caf48d76d469a4d4f47815da56da6d34e9364fb7`. ## Diagnostics vocabulary made precise Two composite `unsupported_features` were half-true after this change, so they were split into what is actually still missing: - `typed_door_window_discrimination_and_host_binding` now fires only when no typed door or window is exported at all. When they are exported but carry no host, the narrower **`door_window_host_wall_binding`** fires instead. - New **`revit_element_parameters_to_ifc_property_sets`** fires while every exported `IfcPropertySet` is rvt-rs provenance about a recovered body rather than a Revit element parameter (#35). The two manifest rows that previously borrowed the door/window feature name now use accurate ones. - `schema_field_wall_instances` keeps firing (see above). ## Docs `docs/status.md`, `docs/support-matrix.json` (`column-instance-recovery` → `element-record-instance-recovery`, still `verified`, scope restated for four categories; `typed-door-window` and `schema-field-wall` stay `unsupported` with their honesty invariants intact), `docs/verification-protocol.md` edges table + honesty note, `docs/supported-profile.md`, `README.md` (three surgical lines), `CHANGELOG.md`, and the new RE-21 report. ## Gates run `cargo fmt --all`, `cargo clippy --profile ci --all-targets -- -D warnings`, `RUSTDOCFLAGS="-D warnings" cargo doc --no-deps`, `cargo +1.85.0 check --all-targets` (MSRV 1.85, no let-chains), `tools/check-local.sh`, and the full `cargo test --profile ci` suite with `RVT_PROJECT_CORPUS_DIR` / `RVT_CORPUS_TIER1_DIR` — all green, including every tier-2 target from #209 (`elem_table_corpus`, `arc_wall_corpus`, `partition_scanner`, `iter_elements_typed`, `re15_geometry_invariants`, `re19_door_window_wall_negative`, `walker_to_ifc_integration`) plus `witness_verdict`, `witness_registry`, `project_count_fixtures`, `support_matrix`. `tests/iter_elements_typed.rs::core_interior_2024_rect_openings_not_fake_doors` now pins the exact counts **and** asserts every recovered Wall/Door/Window carries provenance `partition_schema_mvp::element_category_record`, so the RE-19 negative is enforced by mechanism, not by a zero. ## Merge with #217 `origin/main` at 55491d7 was merged into this branch before the final measurement, so every number above is post-#217. The STEP emitter and `category_map` `predefined_type` values are untouched; the hunks in `src/ifc/mod.rs` are `unsupported_export_features`, the new `STOREY_ELEVATION_SOURCE_TYPES` restriction described above, one re-export line, and one `expect` message. ## Follow-ups - #212 slab instance identity — the rule does not hold there; the record bbox is also the obvious source for the unresolved extrusion thickness. - Door/window host-wall binding (`door_window_host_wall_binding`) — the record body past `+0xa8` was dumped but not yet mined for a host reference. - `docs/octetproof-spec.md` §6's worked verdict example is a two-lineage snapshot and was already stale before this PR (the committed verdict has three lineages); refreshing a published 1.0.0 artifact is a separate call. - `+0x46` / `+0x4a` remain unattributed; their values correlate with class, which may be a schema class-id join worth a look. <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Medium Risk** > Changes core decode/IFC export and cross-witness gates for a corpus-proven Revit 2024 edge; scope is narrow but wrong instance filtering would skew real-project exports and CI verdicts. > > **Overview** > **Revit 2024 partition element records** now drive typed **Wall, Door, Window, and Column** recovery using a direct byte rule instead of the retired #204 column heuristic (family-local bbox drop + highest-`ElementId` per footprint). Records decode **container reference** at `+0x32` and **placement kind** at `+0x42`; `PartitionElementRecord::is_exported_instance` keeps only standalone placed instances. On Core Interior that matches Revit’s export **ElementId sets** at tolerance 0 (360/132/6/256), with bbox envelope geometry and shared `RvtElementRecordGeometry` property sets in IFC. > > **Production and verification** wire walls/doors/windows through `partition_schema_mvp::instances_from_partition_category_records`, unify element-record geometry in `export_content`, and narrow **storey elevation sourcing** to columns only (`STOREY_ELEVATION_SOURCE_TYPES`) while other record-bodied elements still **bind** storeys by exact base elevation (743/836 bound). OctetProof manifests move walls/doors/windows to **`known`** on the slim edge (8-field claimed surface); diagnostics split host binding vs discrimination and add `revit_element_parameters_to_ifc_property_sets`. RE-19/schema-field walls and door/window **host** binding stay explicitly unsupported; slabs (`OST_Floors`) remain #212 `known_gap`. > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit 2c9d2971d7e42cc2473d0da579485467340216c4. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
DrunkOnJava
added a commit
that referenced
this pull request
Aug 31, 2026
…on PredefinedType (#236) Two conformance fixes to the IFC4 writer, both measured against Revit's own export of the same project. Corpus: `.rvt` sha256 `c805df445d613b408e37337765572021265e3f5dfdc7d1fa53b22ba1600b8014`, slim IFC sha256 `bfdf36ffb0bb768f3409d818403990e64d4c262c6780603be87f8077387ad86d`. ## #232 — every element was placed twice The writer emitted the element's own `IfcAxis2Placement3D` in **both** the `IfcLocalPlacement`'s `RelativePlacement` and the swept solid's `Position`. IFC4 has a conforming consumer compose `ObjectPlacement × Position`, so the element translation was applied twice. Viewers that ignore `Position` drew the file correctly, which is exactly why it shipped on every release: two tools could disagree about the same bytes with neither of them misreading. ### The Position decision, and the export's evidence Read with IfcOpenShell 0.8.5 on `2024_Core_Interior_slim.ifc`, Revit's own exporter is consistent about one thing — **the element translation appears exactly once** — and splits it two different ways depending on the frame the profile is authored in: | Revit entity | `ObjectPlacement.RelativePlacement.Location` | `IfcExtrudedAreaSolid.Position.Location` | |---|---|---| | `IfcWall` #2240 (`SweptSolid` body) | `(48.0, 57.667, 0.0)` | `(0.0, 0.0, 0.0)` — identity | | `IfcSlab` #1590 | `(0.0, 0.0, 0.0)` — identity | `(90.444, 71.185, -0.167)` | | `IfcSlab` #1619 | `(0.0, 0.0, 0.0)` — identity | `(93.5, 69.5, 0.0)` | | `IfcSpace` #186 | `(0.0, 0.0, 0.0)` — identity | `(51.694, 69.556, 0.0)` | Never both. Revit's walls put the location in the placement and leave `Position` at identity because the wall profile is authored in the element-local frame; its slabs and spaces do the mirror image because those profiles are authored in storey coordinates. rvt-rs authors **every** profile in the element-local frame — the rectangle always did, and the plan profile recovered in #231 uses the same frame — and it already carries the location on the element's own `IfcLocalPlacement`. So the correct half of Revit's own convention is the `IfcWall` row: **`Position` becomes the project-level identity placement**, and the placement carries the translation once. That is what this PR does. No entity is added or removed — the per-element axis is still emitted, the solid just stops pointing at it. The representation-map path is deliberately left alone, with a comment saying why: a mapped item resolves as `MappingTarget × MappingOrigin⁻¹ × geometry`, so a `Position` equal to the `MappingOrigin` cancels against the inverse instead of compounding, and `origin_feet` is `[0,0,0]` on every map rvt-rs builds today anyway. ### World-coordinate verification IfcOpenShell geometry iterator, `use-world-coords`, matched by `Tag` against the Revit export, deltas in feet. **BEFORE** | Class | shared Tags | max centroid delta | max min-vertex delta | Tags within 1e-3 ft | |---|---:|---:|---:|---:| | IfcColumn | 256 | 166.0000 ft | 166.0000 ft | 0/256 | | IfcSlab | 80 | 185.3333 ft | 185.3333 ft | 0/80 | | IfcWall | 360 | 170.2500 ft | 166.2500 ft | 0/360 | | IfcDoor | 132 | 166.0748 ft | 166.0000 ft | 0/132 | | IfcWindow | 6 | 157.1805 ft | 155.7300 ft | 0/6 | | Class | Tag | rvt-rs world centroid (ft) | Revit world centroid (ft) | delta (ft) | |---|---|---|---|---| | IfcColumn | 20375 | (48.0000, 220.0000, 159.1667) | (23.8750, 110.0000, 81.5833) | (24.1250, 110.0000, 77.5833) | | IfcColumn | 20376 | (98.0000, 220.0000, 159.1667) | (49.1250, 110.0000, 81.5833) | (48.8750, 110.0000, 77.5833) | | IfcSlab | 20311 | (181.3000, 139.0000, 151.7500) | (88.3000, 69.5000, 75.9167) | (93.0000, 69.5000, 75.8333) | | IfcSlab | 20345 | (187.0000, 139.0000, 151.7500) | (93.5000, 69.5000, 75.9167) | (93.5000, 69.5000, 75.8333) | | IfcWall | 20796 | (122.7500, 162.0000, 159.5000) | (60.1042, 81.0000, 81.7500) | (62.6458, 81.0000, 77.7500) | | IfcWall | 20797 | (96.0000, 138.7500, 159.5000) | (48.0000, 69.1667, 83.5000) | (48.0000, 69.5833, 76.0000) | | IfcDoor | 20810 | (194.0874, 118.9189, 156.1247) | (97.0437, 58.0499, 80.0499) | (97.0437, 60.8689, 76.0748) | | IfcWindow | 20898 | (65.4902, 172.2757, 165.9056) | (30.8441, 86.1378, 83.7251) | (34.6460, 86.1378, 82.1805) | The doubling reads straight off the table: the rvt-rs value is 2× Revit's wherever the element's own frame is the whole story — slab 20345 at `(187.0, 139.0)` against `(93.5, 69.5)`, column 20375 at `220.0` against `110.0`. **AFTER** | Class | shared Tags | max centroid delta | max min-vertex delta | Tags within 1e-3 ft | |---|---:|---:|---:|---:| | IfcColumn | 256 | 1.5833 ft | 0.3333 ft | 107/256 | | IfcSlab | 80 | 0.2083 ft | **0.0000 ft** | 79/80 | | IfcWall | 360 | 2.5336 ft | 0.7500 ft | 78/360 | | IfcDoor | 132 | 1.5095 ft | 3.0022 ft | 0/132 | | IfcWindow | 6 | 1.9010 ft | 0.8012 ft | 0/6 | | Class | Tag | rvt-rs world centroid (ft) | Revit world centroid (ft) | delta (ft) | |---|---|---|---|---| | IfcColumn | 20375 | (24.0000, 110.0000, 83.1667) | (23.8750, 110.0000, 81.5833) | (0.1250, -0.0000, 1.5833) | | IfcColumn | 20376 | (49.0000, 110.0000, 83.1667) | (49.1250, 110.0000, 81.5833) | (-0.1250, 0.0000, 1.5833) | | IfcSlab | 20311 | (88.3000, 69.5000, 75.9167) | (88.3000, 69.5000, 75.9167) | (-0.0000, 0.0000, 0.0000) | | IfcSlab | 20345 | (93.5000, 69.5000, 75.9167) | (93.5000, 69.5000, 75.9167) | (-0.0000, 0.0000, 0.0000) | | IfcWall | 20796 | (60.1875, 81.0000, 81.8123) | (60.1042, 81.0000, 81.7500) | (0.0833, 0.0000, 0.0623) | | IfcWall | 20797 | (48.0000, 69.3750, 83.5000) | (48.0000, 69.1667, 83.5000) | (0.0000, 0.2083, 0.0000) | | IfcDoor | 20810 | (97.0437, 59.4594, 80.1247) | (97.0437, 58.0499, 80.0499) | (-0.0000, 1.4095, 0.0748) | | IfcWindow | 20898 | (32.7451, 86.1378, 85.1756) | (30.8441, 86.1378, 83.7251) | (1.9010, -0.0000, 1.4505) | **All 80 slabs now agree with Revit's export on every world-space vertex to 0.0000 ft.** That is the class where rvt-rs recovers a real plan profile (#231), so it is the class where a placement fix can be checked at full precision, and it is exact. The residuals that remain elsewhere are **geometry recovery fidelity, not placement composition**, and each is an existing tracked gap: columns sit 0.125 ft off in plan and 1.58 ft off in Z (insertion point and base elevation), walls up to 2.53 ft on location-curve-derived bodies, and doors and windows carry the record's bounding-box envelope rather than a panel (#86, #82). None of them scales with the element's distance from the origin any more, which is the signature the doubling had. ### The gate `tools/ci/ifc_schema_arity.py` closes the class two ways, both fail-closed: 1. **Structural invariant, every file, every product** — a swept solid's `Position` may not be the very `IfcAxis2Placement3D` instance its product's `IfcLocalPlacement` already uses as `RelativePlacement`. Run against the pre-fix export it produces 992 findings, first one: `#216 IfcColumn reuses #207 as both its ObjectPlacement's RelativePlacement and its IfcExtrudedAreaSolid.Position`. 2. **Pinned composition** — for five elements the gate computes `ObjectPlacement × Position × first-profile-point` explicitly (`ifcopenshell.util.placement`, no geometry kernel) and compares against a pinned coordinate at 1e-6. Two are in `synthetic-project.ifc`, one in `synthetic-structural.ifc` and two are the recorded artifact's column `20375` and slab `20345`, so the probe fires in the fixture-only CI step *and* on the real export. A file that does not hold the Tag skips the probe rather than failing. ## #220 — PredefinedType follows the authoring witness The issue's suggested rule is adopted: where a recorded edge shows the witness's choice, take it. Agreement with the export is what the OctetProof verdicts score, and a value the witness demonstrably wrote is a recorded observation, not an invention. ### Per-type agreement, measured with IfcOpenShell | Entity | Revit's export writes | rvt-rs before | rvt-rs after | rvt-rs count | agreement | |---|---|---|---|---:|---| | IfcWall | `.NOTDEFINED.` ×360 | `.STANDARD.` | `.NOTDEFINED.` | 360 | 360/360 exact | | IfcSpace | `.SPACE.` ×116 | `.INTERNAL.` | `.SPACE.` | 18 | 18/18 exact (recall gap tracked separately) | | IfcDoor | `.DOOR.` ×132 | `$` | `.DOOR.` | 132 | 132/132 exact | | IfcWindow | `.WINDOW.` ×6 | `$` | `.WINDOW.` | 6 | 6/6 exact | | IfcColumn | `.COLUMN.` ×256 | `.COLUMN.` | `.COLUMN.` | 256 | 256/256 exact (unchanged) | | IfcSlab | `.FLOOR.` ×78, `.ROOF.` ×2 | `.FLOOR.` | `.FLOOR.` | 80 | inside the witness's value set (unchanged) | | IfcShadingDevice | `.NOTDEFINED.` ×20 | `$` | `$` | 20 | **not changed — see #235** | `Area`, `Space` and `GenericModel` keep `$`: no recorded edge shows what the witness does with those Revit classes, and inventing a value is the thing this table exists to avoid. `IfcSlab` keeps `.FLOOR.` for all 80 because splitting floors from roofs is a per-element decode, not a mapping default; the gate accepts `{FLOOR, ROOF}` for that type. `IfcShadingDevice` is the one row the witness rule reaches that this PR does not change — `category_map.rs` carries an explicit prior decision for it ("`$`, not an invented `.NOTDEFINED.`"), and flipping a written-down decision deserves its own verdict rather than riding along here. Filed as **#235**. ### No new observation surface class `PredefinedType` is an attribute value; the observation payload counts entity **type names** plus relations and storeys. Both changes are therefore invisible to the observation hash, which was confirmed rather than assumed — see below. So instead of widening the surface, the agreement check went into the arity gate as `--witness-agreement`, run on the recorded artifact in CI: ``` PredefinedType agrees with the witness: IfcColumn.COLUMN=256, IfcDoor.DOOR=132, IfcSlab.FLOOR=80, IfcSpace.SPACE=18, IfcWall.NOTDEFINED=360, IfcWindow.WINDOW=6 ``` `IfcDoor` and `IfcWindow` also joined `PREDEFINED_TYPE_REQUIRED`, since every `category_map` row for them now supplies a value. ## Observations did not move Regenerated all three witnesses on both recorded edges and diffed against the committed files: | Edge | rvt-rs | ifcopenshell | ifc-lite | verdict | |---|---|---|---|---| | `magnetar-2024-core-interior` | byte-identical | byte-identical | byte-identical | PASS, 6 fields, 0 diffs, replay match ×3 | | `magnetar-2024-core-interior-slim` | byte-identical | byte-identical | byte-identical | PASS, 13 fields, 0 diffs, replay match ×3 | **Nothing under `research/witness/` was regenerated, because nothing moved.** Entity counts, relations and storeys are unchanged. ## Fixtures Both committed fixture IFCs are regenerated with their test pins, since the writer change alters them: - `synthetic-project.ifc` — 7 `IFCEXTRUDEDAREASOLID` rows repoint from the element axis to `#14` (the project identity placement), 4 `IFCWALL` move to `.NOTDEFINED.`, the door and two windows gain `.DOOR.` / `.WINDOW.`. - `synthetic-structural.ifc` — 4 `IFCEXTRUDEDAREASOLID` rows repoint to `#14`. Its `predefined_type` values are hardcoded in the test model, not looked up, so they are untouched. `synthetic-project.ifc` also picks up a change it should have carried since #222: it was last dumped at `55491d7` (#217), before `7f00dce` gave `IfcOpeningElement` the `Tag` of the element that fills it, so its one opening still wrote `$` there. Fixtures only regenerate behind `DUMP_IFC=1`, which is how it drifted a commit behind the writer with no test noticing. Two Rust tests moved with the mappings: `lookup_known_class` now expects `.NOTDEFINED.`, and `door_and_window_have_no_predefined_type_by_default` — which asserted the old decision — is rewritten as `door_and_window_follow_the_witness_predefined_type`, with a comment recording why the old reading (type variance belongs on `IfcDoorType`) is defensible and still wrong here: Revit populates both. A new `witness_following_predefined_types` covers all five changed rows. ## Verification run | Gate | Result | |---|---| | `cargo fmt --all` | clean | | `cargo clippy --all-targets -- -D warnings` | clean | | `cargo +1.85.0 check --all-targets` | clean | | `cargo test --profile ci` × 6 named targets, corpus set | 16 passed, 0 failed | | Tier-two decoder gates (#209), 7 targets, corpus set | 40 passed, 0 failed | | `cargo test --profile ci --workspace --all-targets`, corpus set | 152 result blocks, 0 failed | | `tools/ci/ifc_schema_arity.py --witness-agreement` on a fresh export | pass — 20105 instances, 992 solids, 2 pinned probes matched | | Same gate on the pre-fix export | fails, 992 composition findings | | `tools/ci/validate-real-ifc.py` (Einhoven) | pass | | `tools/check-local.sh --ifcopenshell` | all requested gates passed | | OctetProof verdicts, both edges, `--compare-committed` | PASS, replay match on all six observations | ## Follow-ups - **#235** (filed) — `IFCSHADINGDEVICE` emits `$` where Revit writes `.NOTDEFINED.` on all 20; the #220 rule reaches it but a documented prior decision guards it. - Column Z is 1.58 ft off and plan position 0.125 ft off against the export; wall bodies up to 2.53 ft. Both are geometry recovery, now measurable for the first time because the placement no longer swamps them. - Revit splits 80 slabs into 78 `.FLOOR.` + 2 `.ROOF.`; rvt-rs writes `.FLOOR.` for all 80. Closes #232 Closes #220 https://claude.ai/code/session_01BaHKf1Rw5aJBGK5y3xmx7C <!-- CURSOR_SUMMARY --> --- > [!NOTE] > **Medium Risk** > Changes core IFC geometry placement and attribute emission for all extruded products; mitigated by new fail-closed CI gates and unchanged OctetProof observation hashes per the PR description. > > **Overview** > Fixes two IFC4 writer conformance issues measured against Revit's export of the 2024 Core Interior project. > > **Placement (#232).** Swept solids no longer reuse the element's `IfcAxis2Placement3D` as both `IfcLocalPlacement.RelativePlacement` and `IfcExtrudedAreaSolid.Position`. Translation lives only on the local placement; solid `Position` is the project identity frame so `ObjectPlacement × Position` is not applied twice. The same rule applies to extrusions, openings, and the generic `emit_solid_shape` path (mapped-item geometry is documented as a separate composition case). > > **PredefinedType (#220).** `category_map` now emits witness-aligned values where a recorded edge exists: walls `.NOTDEFINED.`, rooms `.SPACE.`, doors `.DOOR.`, windows `.WINDOW.` (replacing `.STANDARD.`, `.INTERNAL.`, and `$`). Tests and docs/compatibility tables are updated accordingly. > > **CI and gates.** `tools/ci/ifc_schema_arity.py` adds placement-composition checks on every file (no shared placement instance; pinned Tag probes) and optional `--witness-agreement` for the real-project export in CI. Synthetic IFC fixtures are regenerated (solid positions, enum values, opening `Tag` catch-up from #222). > > <sup>Reviewed by [Cursor Bugbot](https://cursor.com/bugbot) for commit dff9f2eccb02b3ffe3008181ebbca89253db4970. Configure [here](https://www.cursor.com/dashboard/bugbot).</sup> <!-- /CURSOR_SUMMARY -->
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Two IFC4 writer fixes that share the same emitted files, so they are measured together.
#214 — every emitted instance now carries the full IFC4 attribute list
The writer emitted building elements with
IfcProduct's seven attributes plusTagand stopped. IFC4 requires an instance to list every attribute its entity type declares — an unknown optional occupies its slot as$, it is not dropped — so those records were non-conformant, and reading the attribute raised:IfcEntity::BuildingElementnow carries apredefined_typepopulated fromcategory_map, and emission is driven by a per-type attribute layout table.Attribute arity, before → after
Measured with IfcOpenShell 0.8.5 by counting top-level attributes in the STEP text and comparing with
schema_by_name("IFC4").declaration_by_name(<name>).attribute_count().2024_Core_Interior.rvt(sha256c805df44…), emitted byrvt-ifc:IFCCOLUMNIFCSLABIFCSPACEMismatching instances on that file: 338 → 0, across all 33 emitted entity types.
tests/fixtures/synthetic-project.ifc:IFCWALLIFCSLABIFCSTAIRIFCBUILDINGELEMENTPROXYIFCDOORIFCWINDOW10 → 0 mismatching.
tests/fixtures/synthetic-structural.ifc:IFCCOLUMNIFCBEAMIFCFURNITUREIFCDOORIFCISHAPEPROFILEDEF11 → 0 mismatching.
Three further arity defects the same audit surfaced, not exercised by the files above but fixed at the emission site:
IFCISHAPEPROFILEDEFFlangeEdgeRadius,FlangeSlope(IFC4 additions over IFC2X3)IFCCLASSIFICATIONREFERENCESortIFCMATERIALLAYERSETUSAGEReferenceExtentPlus
IfcBuildingStorey.Elevation, which was written as a bare integer literal (…,.ELEMENT.,0);) where ISO-10303-21 requires a REAL — now0.000000.PredefinedType values
category_mapalready held them; they are now written. Cross-checked against Revit's own export of the same file:Column/StructuralColumn.COLUMN..COLUMN.(256/256)Floor.FLOOR..FLOOR.(78/80; 2 are.ROOF.)Wall/ArcWall.STANDARD..NOTDEFINED.Room.INTERNAL..SPACE.Where
category_maphas no value the slot is written as$— the writer never invents an enum token. Two related changes fell out:IFCSPACEslot 8 isLongName, notTag.IfcSpaceis anIfcSpatialStructureElementand declares noTagat all, so the type GUID the writer used to put there was in the wrong slot. It now carries the element name, withCompositionType = .ELEMENT.matching Revit's export.PredefinedTypedegrades to$. A STEP enumeration reference is written bare between dots and has no escape form, so a value with a quote or a dot in it would corrupt the record;tests/fuzz_regressions.rsdrives adversarial names through the path.Making the gap impossible to reintroduce
tools/ci/ifc_schema_arity.pyre-derives every entity's declared attribute count from the IFC4 EXPRESS schema and compares it with the count actually written, for every instance in the file, plus a null check onPredefinedTypefor the entity types where everycategory_maprow supplies one (IfcBeam,IfcColumn,IfcCovering,IfcMember,IfcSlab,IfcWall). This is the check that was missing: IfcOpenShell'sopen()happily parses a short record, so the existing count-only gate never saw the defect.Wired into three places:
ifcopenshell-validateCI job, over both committed fixtures and the freshly emitted real-project IFC;tools/ci/validate-real-ifc.py, so the existing real-project gate covers it too;tools/check-local.sh --ifcopenshell.Plus Rust-side tests that need no Python toolchain: a table of the 28 emitted entity types with their schema-declared arity, asserted against both the writer's layout table and the emitted text; a sweep proving every
category_maprow resolves to a covered type; slot-position assertions forPredefinedType; and the hostile-token test.Local validation output
Both committed fixtures were regenerated. Entity text changes; entity counts do not.
#213 — storey elevations from the element-record bbox distribution, then bind
src/element_record_storeys.rsturns the distinct basezof the partition element records into building storeys, andifc::apply_element_record_storeyscontains each recorded element in the storey whose elevation equals its base.Storey measurements on
2024_Core_Interior.rvtReference is
IFC Exports/2024_Core_Interior_slim.ifc(sha256bfdf36ff…), read with IfcOpenShell 0.8.5. That file's length unit isFOOT(IfcConversionBasedUnit … 'FOOT'), so itsElevationvalues are feet; rvt-rs writes metres and is converted for the comparison.diagnostics.exported.storey_count0.0, by accident)IFCRELCONTAINEDINSPATIALSTRUCTUREunsupported_geometry_missing_levelColumn distribution across the recovered storeys (24/24/24/24/23/23/23/23/23/23/22 = 256):
The remaining 82 unbound elements are the 64 plan-loop
IFCSLABboundary annotations and 18 name-onlyIFCSPACErows, neither of which carries a record bbox — they keepstorey_index: Noneand fall to the writer's default container, which is the honest state.Note on #213's premise: the issue predicted ten distinct base elevations; the measurement on the recovered record set is eleven, with 166 ft (the export's
Level 12) the additional one.What is not claimed
Storey names are not recovered with the elevations, and this is a measured refusal rather than an omission. There are 12 recovered Level-like name candidates against 11 measured elevations, so the fail-closed rule the ArcWall path already uses (transfer names only when the counts match) does not fire — and checking a rank join against the reference confirms it would be wrong: it puts
Level 6at 91 ft where the export putsLevel 7. Every storey is therefore labelledElevation N ft, the 12 names stay visible indiagnostics.decoded.production_class_counts.Level, and a diagnostics warning states the situation:Level ElementId binding stays unsolved — #86 / RE-20 is untouched,
LevelBindResolvedstaysfalse, and elements bound by elevation additionally carryStoreyBindSource = record_base_elevationso the two joins can never be confused.Fail-closed on both halves
Levelrows carry no elevation of their own (all at one value) and at least two distinct elevations were measured. The 2023 ArcWall path, which already recovers real elevations, is untouched — verified on the Einhoven sample: 4 storeys, 4 containment relations, byte-identical behaviour.Noneboth on a miss and on an ambiguity (two storeys inside the window).Level 1base at-1.9e-14ft rather than0.0.Diagnostics
New:
exported.storey_elevations_feet(aligned with the existingstorey_names; an all-zero list is the honest signal that only name strings were recovered) andexported.storey_bound_elements. Documented indocs/export-diagnostics.mdunder a new Storey provenance section.Witness observations and verdicts
The #214 change alters entity text, not counts, so it needed no regeneration on its own. The #213 change does move counts, so both
rvt-rs.jsonobservations were regenerated perdocs/verification-protocol.md§ OctetProof alignment:IFCBUILDINGSTOREYIFCRELCONTAINEDINSPATIALSTRUCTUREIFCLOCALPLACEMENTIFCPROPERTYSINGLEVALUEstorey_countobservation_hash_sha256for both artifacts:8f2282bc280c2c103dd54fa7fe6e20dae71811598064871b790e033676ae62be→b1ae3c34ebf7b6261c11d65b67af240e1c398ac046f4e8838ca3a356080181d8. The two bridge observations (IfcOpenShell, IFClite) read the reference IFC and are unchanged.Both committed verdicts re-ran and are byte-identical — still
PASS, three lineages, 0 diffs — becauseentity_counts.IFCBUILDINGSTOREYis adecoder_baselinefield and sits outside the claimed surface:Docs and manifests
levels.decoder_expected12 → 11 in both project-count manifests, tolerance 0, with the measurement recorded in the notes.record-elevation-storey-bindrow indocs/support-matrix.json(verified, scope stated: elevations only, Revit 2024, one decoded category).level-elementid-storey-bindstaysunsupported.docs/status.mdstorey paragraph and the IFC4-writer capability row;docs/export-diagnostics.mdfield table + Storey provenance section;CHANGELOG.mdunder Added / Changed / Fixed.Gate
cargo fmt --all·cargo clippy --all-targets -- -D warnings·cargo +1.85.0 check --all-targets(MSRV, no let-chains) ·cargo test --profile ciwithRVT_PROJECT_CORPUS_DIRset, including--test ifc_roundtrip --test ifc_synthetic_project --test ifc_synthetic_structural --test project_count_fixtures --test witness_verdict·tools/check-local.sh --ifcopenshell— all green (916 lib tests).Lane note
src/ifc/export_content.rscarries a deliberately minimal two-line hunk (predefined_type: mapping.predefined_type.map(str::to_string)at the one construction site, plus the same field in one test literal) — the wall/door/window lane owns that file.src/partition_schema_mvp.rsis untouched: the #213 join reads the record base elevation back off the emitted element via itsBodySourceproperty, so nothing in the recovery path had to change, and a round-trip test pins that coupling.Closes #214
Closes #213
https://claude.ai/code/session_01BaHKf1Rw5aJBGK5y3xmx7C
Note
Medium Risk
Changes core IFC export (STEP writer and spatial containment) and shifts real-project diagnostics/witness hashes, but behavior is heavily regression-tested and gated by schema-arity CI.
Overview
This PR fixes IFC4 STEP conformance (#214) and measured storey containment on Revit 2024 Core Interior (#213), with regenerated fixtures, witness observations, and new CI gates.
#214 — writer emits every declared attribute. Building elements were one or more attributes short (e.g.
IFCCOLUMNat 8 vs 9), which brokePredefinedTypereads in strict consumers.step_writernow uses per-type tail layouts, fills unknown optionals with$, mapspredefined_typefromcategory_map, fixesIFCSPACE(LongNamevsTag), and patches arity onIFCISHAPEPROFILEDEF,IFCCLASSIFICATIONREFERENCE, andIFCMATERIALLAYERSETUSAGE. Storey elevations are emitted as REAL literals. Hostile enum tokens degrade to$.tools/ci/ifc_schema_arity.pycompares EXPRESS-declared arity (and requiredPredefinedType) against every STEP instance; it runs in CI,validate-real-ifc.py, andcheck-local.sh --ifcopenshell, with matching Rust arity tests.#213 — storeys from partition element-record base
z. Newelement_record_storeysderives distinct bbox elevations intoIfcBuildingStoreyrows when existing levels have no elevation evidence, then binds record-sourced columns by exact elevation (fail-closed on miss/ambiguity). Core Interior goes 12 → 11 storeys (measured vs name-only), 1 → 11IfcRelContainedInSpatialStructure, 256 elements storey-bound; names stayElevation N ftwhen 12 Level strings cannot pair with 11 elevations. Diagnostics addstorey_elevations_feetandstorey_bound_elements.Reviewed by Cursor Bugbot for commit 8c9b1e7. Configure here.