Repository navigation
docs: ducts, fittings, opening cut loops, the stub wall and family revolutions read as the code does (#96, #227, #1067, #1189) - #1963
Merged
Conversation
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
Ten doc lines that said less than the code does, found by the issue triage batch (batch 10) and each checked against
main:docs/supported-profile.md, Pipes row: "ducts and fittings keep their box" was stale. A duct is its record's swept section, its box within 0.01 ft of Revit's on all 1,053 ducts of Snowdon Towers HVAC and all 25 of RE1 Mechanical (RE-371). A fitting whose saved mesh decodes whole is drawn from it on 2023 to 2027 (W6: draw family instances from their saved meshes by default (decode the remaining saved-graphics faces) #1191), RE-443 adding 105 duct fittings ofrme_basic2023 checked against a native reference that is not shared, not a Revit export; any other keeps its box. Flex ducts are not read. (CLASS-16: MEP: the duct family, sloped runs, fittings and route geometry left after pipes and ducts #96)docs/supported-profile.md(doors, windows and openings row) anddocs/evidence.md(openings row): the cut-loop opening was said to be 2024 and 2025 only.CUT_LOOP_REVIT_VERSIONSis 2024 to 2027 (RE-346) andCUT_LOOP_32BIT_REVIT_VERSIONS2015 to 2023 (RE-450). On 2015 to 2023 the size is the 2024 save's and the place too, but for 24 windows ofrac_advanced's 2015 to 2020 saves 0.0075 m off (RE-450); on 2026 and 2027 the 2025 save's (RE-346); neither is held to a Revit export of those releases, and the lines say so. (Opening geometry from the symbol's cut loop on releases other than 2024 and 2025: no Revit export of another release's openings is in CI #227)docs/release-1.0-criteria.md, W4's wall-top line: the stub wall 3004978 "keeps its full height" was stale. fix(ifc): a wall whose floor covers all of its plan but a stub inside another wall is cut whole, as Revit cuts it, and counted apart (#1067) (RE-375) #1596 (RE-375) cuts it whole, labelled and counted apart, by a rule that rests on that one wall. The counts beside it are from before that change, and the line now says so. (Walls drawn taller than Revit's body on 78 of the BIM4LCA office's walls (RE-257) #1067)docs/supported-profile.md, Family row, anddocs/release-1.0-criteria.md, W3: the family geometry said "none". A standalone Revit 2020 family's one visible positive revolution is exported, confirmed against Revit's own IFC of the family (RE-394), asdocs/compatibility.mdand the support matrix already say, marked experimental as the README marks it. W3 stays failed. (W3: read family (.rfa) and template (.rte, .rft) files like projects: types, parameters and geometry #1189)docs/rooms.mdanddocs/reference-models.md: BIM Whale's held-out Revit 2021 project was said to write 0 of its 8 Areas. Since RE-333 it writes 6 of 8 with no extras, and 2 of Revit's are still missing (Measure run 42003913780, counts only). (Revit 2018 and 2021 projects decode with no rooms (Revit's IFC has 73 and 8) #1261)docs/supported-profile.md, "Not supported": rebar, Structural Beam Systems and Revit assemblies now say why they are not read (RE-350 §3, §3.3), which rvt-rs reads no reinforcing bars or element assemblies #1444's done-when asks for. The files hold rebar and beam systems as framed boxes, but no Revit export in reach shows what Revit writes for them. (rvt-rs reads no reinforcing bars or element assemblies #1444)docs/support-matrix.json, the raised embed-host claim ("all are drawn from their mesh and every base is Revit's", run 41973316830): since RE-444 (fix(elements): of an element framed in several partitions the exporter keeps the newest frame, not the one with the greatest height (#1710) (RE-444) #1799), 2177212 at permit is drawn from its newest frame's record box, its base 8.2021 ft below Revit's, and the matrix now says so. (Wall 2177212: its saved mesh is 0.114 ft shorter than Revit's IFC body (RE-340 follow-up) #1407)Testing
Docs only.
tools/ci/api-doc-ids.pyandtools/ci/measured_numbers.pypass locally (276 of 294 numbers name a model of the index).Audit-honesty checklist