fix(elements): a door or window with no curtain grid found whose list names one wall in all, a curtain wall, is a part of it (#1912) (RE-453) - #1913
Merged
Conversation
… names one wall in all, a curtain wall, is a part of it, so the 84 office doors Revit aggregates are (#1912) (RE-453)
…list, grid, element data and record box say about the curtain wall Revit's export puts it in, for the 84 office doors still out of their wall (#1912)
…s list holds, and the scorer groups the openings by it and scores a rule that needs the list to name one wall (#1912)
…and 6 of 6 Snowdon doors, and the saves of each sample project agree (#1912) (RE-453)
DrunkOnJava
marked this pull request as ready for review
November 13, 2026 15:28
Owner
Author
|
Self-approved as rvt-rs-review[bot] under Griffin's 2026-11-12 answer ("You are allowed to self-approve"). rvtDevelop was sent this head at 15:33 UTC and had not answered 40 minutes later; its last approval today was at 10:09 UTC. I re-read the delta as a second reader would: |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
A door or window with no curtain grid found whose reference list names one wall in all, and that wall a curtain wall, is a part of that wall (RE-453). RE-452 aggregated such an opening only when the element data of an id in its list named the wall too, which left out 84 of the 268 doors that Revit's export aggregates into a curtain wall on the four BIM4LCA offices (21 in each). An opening whose list names a curtain wall and another wall keeps RE-452's rule.
Motivation
#1912. The probe and its scorer (the first two research commits) read what each door's list, grid, element data and record box say, against Revit's own export: every door of the offices and of Autodesk's Snowdon Towers Architectural that Revit puts in a curtain wall names that wall alone, and the three Snowdon doors that name a curtain wall and that Revit leaves standalone (RE-46) name their host as well. Rows were registered before the change's Measure was dispatched: comment on #1912.
Changes
src/research/partition_schema_mvp/curtain.rs:attach_curtain_wallstakes the one curtain wall the list names when it is the one wall the list names (walls_named); the element-data arm of RE-452 now runs only for a list that names another wall too.probes/examples/probe_1912_curtain_openings.rs,tools/re/curtain_openings_vs_ifc.py: the probe and the scorer (research commits, already run in Measure 43439124110 and 43441941672).reports/element-framing/RE-453-curtain-openings-one-wall.md,docs/status.md,changelog.d/fixed/1912-curtain-door-one-wall.md, and a pointer in RE-452.Testing
Unit tests are banned in this repository; the change is measured end to end:
rac_advancedsaves and Snowdon Towers Architectural (Revit's export held locally, counts only): the rule gives 268 of 268 office doors and 6 of 6 Snowdon doors, with no door in another wall and none that Revit leaves out (report section 2).diagnostics.jsonidentical on 121 of 121.rac_advanced,rac_basic,rme_advancedandrme_basicsave of 2015 to 2027 (43450027177): the doors and windows that are parts of a curtain wall are the same on every save of a project (17, 5, 17, 17), where they differed by release before (0 on 2015 to 2023); none is lost.Not measured: windows (none is in a curtain wall in any export held); the Vitoria 2018 model leaves the runner as counts, and its openings' hosts are as on
main.Audit-honesty checklist
docs/status.md)changelog.d/Legal and contribution hygiene
Breaking changes
None. A door or window of a curtain wall that was a standalone
IfcDoororIfcWindowis a part of the curtain wall (and takes itsIsExternal) on the files the rule reaches.Related issues