Repository navigation
feat(ifc): a flat roof written as a slab carries its Qto_SlabBaseQuantities.Perimeter (#1208) - #1774
Closed
DrunkOnJava wants to merge 2 commits into
Closed
DrunkOnJava wants to merge 2 commits into
DrunkOnJava wants to merge 2 commits into
Conversation
…t computes (RE-247)
…tities.Perimeter (#1208)
Owner
Author
|
Superseded by #1785: the stack was rebuilt after the second read (the pipe change left it and two rules were narrowed), so this change sits on new commits. |
7 tasks done
DrunkOnJava
added a commit
that referenced
this pull request
Nov 12, 2026
…tities.Perimeter where its outline is square-cornered (#1208) (#1785) ## Summary On the BIM4LCA office as built Revit's export writes `Qto_SlabBaseQuantities.Perimeter` on 29 objects where rvt-rs writes none. Thirteen of the office's 42 slab perimeters are already counted apart as Revit's feet-unscaled defect (RE-235 §5, `REVIT_DEFECTS` in `tools/re/qtos_vs_ifc.py`); the other 29 are scored missing. Reading the 42 values against the profile each slab's body extrudes splits them cleanly in two, and the split is the element's class: **every `.ROOF.` slab's value is the outline's length in the file's unit, and every floor's, base slab's and stair landing's is that same length in feet.** This writes the roof ones — 10 of the 29 — and leaves the rest out with the reason stated. ## Evidence I mapped each of the 42 `Qto_SlabBaseQuantities` sets of `revit.ifc` to its `IfcSlab` (through its `IFCRELDEFINESBYPROPERTIES`) and to the `GrossArea` written beside its `Perimeter`, then read the profile the slab's body extrudes. The two readings of one value differ by 304.8, so each of the 42 is unambiguous against its area: | | as the file's unit (mm) | as feet | |---|---:|---:| | the 10 `.ROOF.` slabs | 4.7 to 197.9 m, 1.00 to 3.06 times `4*sqrt(area)` | 1,429 to 60,315 m | | the 32 `.FLOOR.`/`.BASESLAB.`/`.LANDING.` slabs | 0.020 to 0.87 m, far under `2*sqrt(pi*area)` | 5.8 to 264 m, 0.8 to 1.9 times `4*sqrt(area)` | Checked to the last digit where the profile is a plain outline in the export: - `Basic Roof:KA-1` 1461758 (area 261.2999 m²): outline 188,699.718 mm of lines plus two quarter arcs of radius 2925 mm, 197,888.88 mm against Revit's 197,888.87629548809. - `Basic Roof:YP-1` 2991742 (area 614.7886): 158,585.00 mm against 158,584.9999999993. - `Basic Roof:YP-4` 3165182 (area 491.8956): a 26,385 by 18,643 rectangle, 90,056.00 mm against 90,056.0000000018. - `Floor:VP-1` 1384047 (area 1017.0252): outline 174,303.6 mm plus its 6 holes 42,700.7 mm, 217,004 mm, against 743.65029082242927 read as feet, 226,664 mm — the export counts a hole's outline in its value. - `Floor:AP-2` 1439250 (a landing, area 16.6319): 2×(2,760.48 + 6,025) = 17,570.95 mm, against 57.64750022310872 ft = 17,571 mm. So the rule is narrowed to the class the evidence carries: **a roof** whose `GrossArea` the export writes (the scope `add_slab_gross_area` already uses for a flat roof: drawn as one extrusion of its sketch's outline, not sloped, its type's layers filling its body) and whose profile has no holes gets its `Perimeter`, the length of that outline. Arcs are tessellated at the profile's own 0.0005 ft (Ka-1's two arcs make 4.6% of the outline, so the polygon reads within 1e-6 of the arc length, well inside the census's 1e-5). What stays without, and why: - the 32 floors, base slabs and stair landings: Revit's value there is the length in feet, unscaled (five of them verified above and by the scorer), so writing the length would make 19 values different and 13 still counted apart; - the one `Non-Monolithic Landing` 3058084, whose value *is* the outline in mm (4,688.14 mm for 1.3804 m²): rvt-rs writes no `Qto_SlabBaseQuantities` on a landing at all (RE-295), so there is nothing to add it to; - a roof whose profile has holes: whether the export counts a hole's outline in the value is unmeasured (the office's 10 roofs have no holes; the housing has 2 roofs with holes, RE-413), so `profile_outline_length` returns `None` for `ArbitraryWithVoids`. Not a settled question: the maintainer's RE-235 §5 leaves out "a floor's `Perimeter`" only, issue #1208 (open) lists `Perimeter` among the slab quantities not written with the reason "Revit writes `Perimeter` in feet in a millimetre file", which holds for the floors and not for the roofs; no report or decision covers a roof's, and no merged pull request writes it. ## Changes - `src/ifc/export_content.rs`: `add_slab_gross_area` pushes `Perimeter` (as `PropertyValue::PositiveLengthFeet`) on a roof; a new `profile_outline_length` returns the length of a closed polyline profile and `None` for a profile with voids or another shape. The function's comment now says a floor's is left out and a roof's is written, with what stays without. - `changelog.d/added/1208-roof-perimeter.md`: the new fragment. - `docs/supported-profile.md`, `docs/evidence.md`: the roof's `Perimeter` in the two lists of the base quantities written. No test pins the set (`rg Qto_SlabBaseQuantities tests/` finds nothing), so no test is edited. ## Measured One Measure run scored this change together with nine others it was drafted beside (run 43086493417, head `f5f54467`, base `5e3ac5b0`: every model, with the BIM4LCA office and housing, the Revit 2025 models, Autodesk's samples of every release, rac_advanced, BIMcollab and the held-out pairs; every shard and both same-project gates passed; rows registered on #1636 before it was read). Each change writes a value of a different name, so the rows below are this change's alone. Both sides' exports were kept, and the 58 sample saves, which no Revit export scores, were compared value by value. After the second read the stack was rebuilt on `main` as seven changes (the pipe change left it, and the roof and floor-opening rules were narrowed to square-cornered outlines) and measured once more in full (run 43100937918, head `53c19487` against `e8a99d03`, rows registered first, read on #1636): all shards and both same-project gates pass, "different" and "values Revit does not write" are unchanged on every model, and the rows below repeat except where a line says otherwise. | Model | `Qto_SlabBaseQuantities.Perimeter` equal, before | after | different | |---|---:|---:|---:| | Office as built | 0 of 29 | 10 of 29 | 0 | | Office at permit | 0 of 29 | 10 of 29 | 0 | | Timber office as built | 0 of 28 | 8 of 28 | 0 | | Timber office at permit | 0 of 28 | 1 of 28 | 0 | | Concrete housing as built, at permit | 0 of 24, 0 of 20 | 1 of 24, 4 of 20 | 0 | | Timber housing as built, at permit | 0 of 28 each | 3 of 28 each | 0 | - The draft predicted the office's 10 and left the timber office and the housing open: they read equal too, and no model gains a value Revit's export does not write, the held-out pairs included. - Sample saves: none gains a value from this change. - **Narrowed after the second read:** a roof whose outline has a corner that is not a right angle now gets none. A sketch arc reaches the outline as chords within 0.0005 ft, whose length is short of the arc's by about a third of sagitta over radius; no corner between two chords is square, so a square-cornered outline holds no arc. The counts above are from before the narrowing. **After it (the final run):** 9 of 29 on each concrete office file, one fewer, and every other count as above (8 and 1 of 28, 1 of 24, 4 of 20, 3 and 3 of 28), none different. The one roof that fell on each office file read equal before, so its outline has a slanted straight edge, not an arc. ## Still open - A roof whose profile has holes gets none: whether Revit counts a hole's outline is not measured. - A roof whose outline has a slanted straight edge is left out with the arcs. Carrying the sketch's arcs to the outline and taking their length exactly would reach both. - A floor's `Perimeter` stays out: Revit's export writes it in feet in a file whose unit is millimetres (RE-235 section 5). Stack: this is change 6 of 7; each branch holds the ones before it, so its own diff is its last commits until those land. First draft: #1752, then #1774. ## Testing - Built, linted and tested by CI on this head; nothing was built on a workstation. - Verified end to end on real Revit files against Revit's own exports: the Measure runs named above, which anyone can repeat with `gh workflow run measure.yml --ref main -f ref=<this head> -f base=e8a99d03be8a76a2c8871ea8cc28d036653ec6e2 -f nordic=true -f r2025=true -f samples=true -f racadv=true -f bimcollab=true -f holdout=true`. - No test was added: no unit test, and no pinned count moves except where the body says so. - `main` has moved since those runs (#1769 re-meshes trimmed faces, and the six batch changes before this one landed). This head, `99db61c5`, is `main` at `1fe64d99` merged in, with two docs lines merged word by word; its change against `main` is this pull request's own two commits and nothing else (byte-equal outside `docs/`, word-equal inside). Measure 43108424934 measured the nine batch changes together on `main` with #1769 (`3f2a04c4` against `e7ac68e7`, rows registered on #1636 first): every count above repeats, and the same-project gates pass. ## Audit-honesty checklist - [x] Docs state what this change writes and what it leaves out - [x] A changelog fragment under `changelog.d/` - [x] No emojis, private paths or personal data in committed files - [x] Limits are in the body above and in the code's doc comments ## Legal and contribution hygiene - [x] Apache-2.0 - [x] No Autodesk proprietary source, decompiled internals or NDA material. Where revit-ifc (CLEANROOM.md source 5) is cited, it is read and cited by file and class, and no code is copied. - [x] No fixture with real-world personal data ## Breaking changes None.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
On the BIM4LCA office as built Revit's export writes
Qto_SlabBaseQuantities.Perimeteron 29 objects where rvt-rs writes none. Thirteen of the office's 42 slab perimeters are already counted apart as Revit's feet-unscaled defect (RE-235 §5,REVIT_DEFECTSintools/re/qtos_vs_ifc.py); the other 29 are scored missing. Reading the 42 values against the profile each slab's body extrudes splits them cleanly in two, and the split is the element's class: every.ROOF.slab's value is the outline's length in the file's unit, and every floor's, base slab's and stair landing's is that same length in feet. This writes the roof ones — 10 of the 29 — and leaves the rest out with the reason stated.Evidence
I mapped each of the 42
Qto_SlabBaseQuantitiessets ofrevit.ifcto itsIfcSlab(through itsIFCRELDEFINESBYPROPERTIES) and to theGrossAreawritten beside itsPerimeter, then read the profile the slab's body extrudes. The two readings of one value differ by 304.8, so each of the 42 is unambiguous against its area:.ROOF.slabs4*sqrt(area).FLOOR./.BASESLAB./.LANDING.slabs2*sqrt(pi*area)4*sqrt(area)Checked to the last digit where the profile is a plain outline in the export:
Basic Roof:KA-11461758 (area 261.2999 m²): outline 188,699.718 mm of lines plus two quarter arcs of radius 2925 mm, 197,888.88 mm against Revit's 197,888.87629548809.Basic Roof:YP-12991742 (area 614.7886): 158,585.00 mm against 158,584.9999999993.Basic Roof:YP-43165182 (area 491.8956): a 26,385 by 18,643 rectangle, 90,056.00 mm against 90,056.0000000018.Floor:VP-11384047 (area 1017.0252): outline 174,303.6 mm plus its 6 holes 42,700.7 mm, 217,004 mm, against 743.65029082242927 read as feet, 226,664 mm — the export counts a hole's outline in its value.Floor:AP-21439250 (a landing, area 16.6319): 2×(2,760.48 + 6,025) = 17,570.95 mm, against 57.64750022310872 ft = 17,571 mm.So the rule is narrowed to the class the evidence carries: a roof whose
GrossAreathe export writes (the scopeadd_slab_gross_areaalready uses for a flat roof: drawn as one extrusion of its sketch's outline, not sloped, its type's layers filling its body) and whose profile has no holes gets itsPerimeter, the length of that outline. Arcs are tessellated at the profile's own 0.0005 ft (Ka-1's two arcs make 4.6% of the outline, so the polygon reads within 1e-6 of the arc length, well inside the census's 1e-5).What stays without, and why:
Non-Monolithic Landing3058084, whose value is the outline in mm (4,688.14 mm for 1.3804 m²): rvt-rs writes noQto_SlabBaseQuantitieson a landing at all (RE-295), so there is nothing to add it to;profile_outline_lengthreturnsNoneforArbitraryWithVoids.Not a settled question: the maintainer's RE-235 §5 leaves out "a floor's
Perimeter" only, issue #1208 (open) listsPerimeteramong the slab quantities not written with the reason "Revit writesPerimeterin feet in a millimetre file", which holds for the floors and not for the roofs; no report or decision covers a roof's, and no merged pull request writes it.Changes
src/ifc/export_content.rs:add_slab_gross_areapushesPerimeter(asPropertyValue::PositiveLengthFeet) on a roof; a newprofile_outline_lengthreturns the length of a closed polyline profile andNonefor a profile with voids or another shape. The function's comment now says a floor's is left out and a roof's is written, with what stays without.changelog.d/added/1208-roof-perimeter.md: the new fragment.docs/supported-profile.md,docs/evidence.md: the roof'sPerimeterin the two lists of the base quantities written.No test pins the set (
rg Qto_SlabBaseQuantities tests/finds nothing), so no test is edited.Measured
One Measure run scored this change together with nine others it was drafted beside (run 43086493417, head
f5f54467, base5e3ac5b0: every model, with the BIM4LCA office and housing, the Revit 2025 models, Autodesk's samples of every release, rac_advanced, BIMcollab and the held-out pairs; every shard and both same-project gates passed; rows registered on #1636 before it was read). Each change writes a value of a different name, so the rows below are this change's alone. Both sides' exports were kept, and the 58 sample saves, which no Revit export scores, were compared value by value. The eight changes that held are stacked again onmainand measured once more in full (run 43095382793, head52e59f81, rows registered first); this description is updated when that run is read.Qto_SlabBaseQuantities.Perimeterequal, beforeStill open
Perimeterstays out: Revit's export writes it in feet in a file whose unit is millimetres (RE-235 section 5).Stack: this is change 2 of 8 measured together; each branch holds the ones before it, so its own diff is its last commits until those land. First draft: #1752.
Testing
gh workflow run measure.yml --ref main -f ref=<this head> -f base=e8a99d03be8a76a2c8871ea8cc28d036653ec6e2 -f nordic=true -f r2025=true -f samples=true -f racadv=true -f bimcollab=true -f holdout=true.Audit-honesty checklist
changelog.d/Legal and contribution hygiene
Breaking changes
None.