Skip to content

perf(research): a face cut by its trim is cut across at the chord's v steps and at the v of the trim's own steps and cusps, and the triangles of 25 of 126 exports fall (#1737) (RE-437) - #1769

Merged
DrunkOnJava merged 7 commits into
mainfrom
perf/1737-sparse-trimmed-cells
Nov 11, 2026

Conversation

@DrunkOnJava

@DrunkOnJava DrunkOnJava commented Nov 11, 2026 •

Copy link
Copy Markdown
Owner

Summary

A face cut by its trim is cut across at the chord's v steps and at the v of the trim's own steps and cusps, where trimmed_cells cut each strip's trapezoids at every knot of v and face_grid made every trim point's v a knot, so that a trim of T points left every trapezoid that held a point's v cut once more across the whole face. The strips keep a knot at every trim point's u (a trim segment must cross a strip whole, so each corner of the trim is still a corner of the cells). The cuts across them are now the chord's steps and the v of each vertex the trim does not run through from one strip to the next (trim_steps: the ends of a step along a strip boundary and the tip of a hole), because without those a strip's cells run straight past a vertex of the next strip's and leave a crack inside the face. A face meshed on its grid keeps every trim point as a knot on both axes, and a plane face that shares an edge with a cut face follows the same v knots (refined_plane_edge). No element stops being drawn from its saved mesh (BodySource changes 0).

What moves (Measure, 126 exports against main: 101 identical, 25 differ, the same 25 as the first version of this change): the triangles from saved graphics fall by 7.5% on the BIM4LCA office (all 107,887 of them in its 43 toilets, a toilet from 14,025 to 11,516), 6.8% on Snowdon Towers Architectural, 4.6% on the four large housing exports, 3.3% on the two terrain ones and 10.4% on rac_advanced; the IFCs by 0.4% to 6.6% (the office 117.1 to 113.6 MB, Snowdon Towers Architectural 272.1 to 257.6 MB). The cracks are identical per class to main's on the office as built (160 in 57 face sets), the timber office (168 in 57), the housing and RE1, none in a toilet, and fewer on rac_advanced (394 to 374). One measured negative: RE1 Architecture's shower head has its farthest vertex from Revit's surface move from 0.009123 to 0.01007 ft, over the 0.01 ft column of its class.

Motivation

#1737, the second lever of the density RE-430 measured (after RE-435): a toilet's two trimmed faces were 4,147 of its 14,025 triangles. A first version cut at the chord's steps alone and took 8.1% off the office, and rvtDevelop's read counted what its rows had not: the vertices of a face's cells inside a boundary edge of the same face's cells went from 160 to 504 on the office as built, the 344 more all in the 43 toilets. This version keeps the cuts that stop them and the diagnostic is in RE-437.

Changes

  • face_grid (src/research/native_parametric_mesh.rs): the trim points' coordinates join the knots of u; for a face not meshed on its grid the knots of v take the v of the trim's steps and cusps (trim_steps) and no longer every trim point's; trimmed_cells no longer asks a trim point's v to be a knot (a point off the u knots is refused as before). Four failure-first tests of the pure helpers: a trim point between the v knots is a corner and not a cut, a point on a vertical side between them is covered all the same, the vertices a strip beside passes by are the steps and the cusps (an L, a diamond, a square with a diamond hole), and a step of the trim is a vertex of the strips on both sides when its v is a knot while chord steps alone leave a free edge off the trim.
  • tools/re/mesh_tjunctions.py (new): the crack count, per class of the owning product, over a kept export.
  • reports/element-framing/RE-437-trimmed-face-cuts.md, the reconnaissance addendum, changelog.d/changed/1737-trimmed-face-cuts.md, and the sentence of changelog.d/changed/1706-trimmed-faces.md that said every trim point was a knot.

Testing

The measured commit is 70bef87acfbe (ee2d9dfe, the steps rule, merged over main a0c1c61a), archived as refs/archive/2026-11-11/cited/70bef87acfbe; the commits after it change the report, the fragments, the addendum and this description, and no source.

  • Unfiltered Measure with keep_ifc (43091480051, against main a0c1c61a; GitHub's artifact outage of 2026-11-11 failed the uploads of 8 shards, which gh run rerun --failed re-ran as attempt 2) and timing (43091485302). Rows registered on Trimmed faces: an element drawn from a revolved or ruled face costs 9,000 to 17,000 triangles where Revit's export of it costs about 1,700 #1737 before the run (comment 6805810741) all hold: rows 1, 2, 4, 5 and 6 outright; row 3 on its registered columns (against Revit's export no class's median volume moves, and the counts within 1% of its volume and with every vertex of Revit's within 0.001 ft fall on no class), with the shower head's 0.01 ft column as a measured negative (RE-437 section 4); row 6: export time 0.97 to 1.02 and peak memory 0.98 to 1.05 of main's (1.05 asked), the office 1.00 in both.
  • The first version, Measure 43078686248 (code aafa5b1a, kept under refs/archive/2026-11-11/cited/aafa5b1a2f15), held its five rows and left 344 cracks in the toilets: kept as the negative result in RE-437 section 2.
  • same-project gates and the semantic check on the measured commit; full / CI passed on the final head

Audit-honesty checklist

  • A user-visible change has its entry as a fragment under changelog.d/changed/.
  • A reverse-engineering finding has its report: reports/element-framing/RE-437-trimmed-face-cuts.md (status, artefact hashes by run, measured counts, reproduce commands naming a commit).
  • No emojis, no private paths in committed files.

Legal and contribution hygiene

  • Apache-2.0. No Autodesk proprietary source, internals or NDA material.
  • No new test fixtures.

Breaking changes

None.

Related issues

Refs #1737 (the chord, the third lever, stays open). Follows #1715, #1744, #1709.

… steps alone, where every trim point's v was a cut as well (#1737) (RE-436)

The strips between the u knots stay at every trim point's u, so each corner of the trim is still a vertex; the cuts across them were the chord's v steps plus the v of every trim point, which cut every trapezoid that spans a point once more. trimmed_cells no longer asks a trim point's v to be a knot. A face meshed on its grid keeps every trim point as a knot, and a plane face that shares an edge with a cut face follows the same v knots.
…tered rows: 25 of 126 exports move and their triangles from saved graphics fall by 0.6% to 15% (#1737) (RE-437)
… cut by its trim, so no strip's cells run past a vertex of the next (#1737) (RE-437)

Cutting a trimmed face across at the chord's steps alone left 8 cracks in each toilet of the office (rvtDevelop's read of #1769): a trim vertex on a strip boundary that the trim does not run through (the end of a step along the boundary, a hole's tip) is a vertex of one strip's cells only, and the neighbour's cell edge runs straight past it. trim_steps names those vertices and face_grid keeps their v as knots: the same global cut the base made, for these alone, so the strips stay conforming and a plane face that shares the edge follows grid.v. tools/re/mesh_tjunctions.py counts the cracks of a model's faces.
@DrunkOnJava DrunkOnJava changed the title perf(research): a face cut by its trim is cut across at the chord's v steps alone, where every trim point's v was a cut as well, and the triangles of 25 of 126 exports fall (#1737) (RE-437) perf(research): a face cut by its trim is cut across at the chord's v steps and at the v of the trim's own steps and cusps, and the triangles of 25 of 126 exports fall (#1737) (RE-437) Nov 11, 2026
…ws: 25 of 126 exports move, the office's triangles fall 7.5% and its cracks are main's, RE1's shower head is a measured negative (#1737) (RE-437)

The report, the changelog fragment, the 1706 fragment's sentence and the reconnaissance addendum describe the rule as measured: the chord's v steps and the v of the trim's steps and cusps, not the chord's steps alone, which the first version (Measure 43078686248) held its rows with and left 344 cracks in the office's 43 toilets. The figures are Measure 43091480051 (code 70bef87, ee2d9df merged over main a0c1c61, archived under refs/archive/2026-11-11/cited/; attempt 2 re-ran the 8 shards GitHub's artifact outage failed) and timing 43091485302: the triangles from saved graphics fall 7.53% on the office, 6.81% on Snowdon Towers Architectural, 4.6% on the large housing exports and 10.44% on rac_advanced; the cracks of tools/re/mesh_tjunctions.py are main's per class on the office, the timber office, the housing and RE1; BodySource changes 0 and the diagnostics of all 25 moved exports are equal.
@DrunkOnJava
DrunkOnJava merged commit e7ac68e into main Nov 11, 2026
36 checks passed
@DrunkOnJava
DrunkOnJava deleted the perf/1737-sparse-trimmed-cells branch November 11, 2026 21:41
DrunkOnJava added a commit that referenced this pull request Nov 12, 2026
…ght (#1016) (#1783)

## Summary

Revit's IFC4 export of the BIM4LCA office as built writes
`Qto_SpaceBaseQuantities.Height` on 308 minus 44 family-instance spaces;
rvt-rs
writes it on the 234 rooms and on none of the 30 Areas. This change
writes an
Area's `Height` as the height of its body, from its Level up to the
Level above,
on Revit 2024 to 2027, and leaves a Revit 2015 to 2023 Area without one,
since
no export of that release's Area height is measured.

## Evidence

**The task is real and still open.** `docs/rooms.md:134` lists exactly
this value
under "What is not measured" for Areas ("which Revit writes on an Area
and rvt-rs
does not yet"), and the Areas row of `docs/support-matrix.json` says the
same. No
issue closes it against us: #1016 is the open W7 quantity umbrella and
puts the
remainder on #1046, #1165, #1203 (closed, columns), #1207 (spaces'
`GrossVolume`,
stepped rooms' `NetVolume`, Revit 25's area quantities), #1208 and
#1209, none of
which names an Area's height; #763 is closed and is about the 44
family-instance
spaces. `RE-317` §2 measured the value as the same number as the Area's
extrusion
depth on all 30 Areas of both office files, and `RE-324` §"not measured"
leaves it
out for 2015 to 2023. Nothing in the code or docs is a decision against
writing
it.

**Where the 14 are.** From `qtos_vs_ifc.txt`: `Height: 248, equal 234,
different 0,
missing 14`, `on IfcSpace x14`, and 6 more "on a repeated key, against
the object
held: missing 6"; `rvt-rs quantities Revit does not write: 0`, so rvt-rs
writes
`Height` on exactly 234 spaces. `space_kinds_vs_ifc.txt` splits the 308
`IfcSpace`
into 234 rooms, 30 Areas and 44 family instances. In `revit.ifc` a
family-instance space's `Qto_SpaceBaseQuantities` holds `GrossVolume`
and
`NetVolume` and no `Height` (e.g. `#787354`), while every one of the 30
Area
spaces carries a one-quantity `Qto_SpaceBaseQuantities` that is an
`IfcQuantityLength('Height',…)` equal to that Area's
`IfcExtrudedAreaSolid` depth
(e.g. `#69195`, height `3399.9999999999982` and depth
`3399.9999999999982`). The
Areas are `GFA 250mm` 1-5, `GFA` K/1/2/3/P/4/5, `BUSINESS SPACE` LIIK1,
`OFFICE`
TSTO1-TSTO11 and `HEATED NETAREA` K/1/2/3/4/5a.
`tools/re/qtos_vs_ifc.py` keys a
space by its `Name` and counts a repeated key apart: the 6 names shared
by two or
three Areas (1, 2, 3, 4, 5, K) are exactly its 6 "repeated key" heights,
and the
14 missing are the 14 uniquely named Areas — LIIK1, TSTO1 to TSTO11, P
and 5a.
There are no other `IfcSpace` without `Height` in the office's export.

**The rule.** rvt-rs already holds the number: a drawn Area carries
`AREA_BODY_HEIGHT_FIELD` (`m_area_body_height`), the elevation of the
next
building story less its Level's (`RE-317`), and extrudes its body by it.
Against
Revit's own `Height` in the same file the two agree inside the census's
1e-5
relative tolerance: area `1` 3.400000 m against 3399.9999999999982 mm,
TSTO5
3.950000 against 3949.9999999980364, 5a 5.970000 against
5970.0000000000118.
So an Area that rvt-rs draws gets that number; an Area it refuses keeps
none. A
room and a family-instance space are untouched (`ROOM_HEIGHT_FIELD` is
read
unchanged, and neither kind has an Area field).

**What stays out, and why the releases are gated.** A given Revit
release's export
is the oracle only where it exists: the Area height is measured on Revit
2024
(the office, both files, 30 of 30). Revit 2025 to 2027 Areas hold the
same body
height as that save — the same-project gate compares it, with `lowest
and highest
vertex`/`height` in `tools/re/areas_across_saves.py` — and `revit-ifc`
takes the
height from the Level distance for every release (cited in `RE-317` §2),
so they
are written too, labelled like the Areas themselves. A Revit 2015 to
2023 Area
keeps none: the only export of one is an IFC2X3 export whose quantities
are not
measured (`RE-324`). The gate cannot be 2024 alone:
`tools/re/readers_across_saves.py`
compares the sample projects' saves from `FIRST_YEAR = 2024` against the
2025 save
and fails a property written here and not in the reference, and
`Qto_SpaceBaseQuantities.Height` is in its `ADDED` list. An Area that
rvt-rs
refuses a body for still has no `Height`, so on a project where Revit
writes one
on a refused Area the value stays missing, not wrong.

## Changes

- `src/research/partition_area_records.rs`: `AREA_SPACE_HEIGHT_FIELD`
(`m_area_space_height`) and `AREA_HEIGHT_REVIT_VERSIONS` (`2024` to
`2027`), and
a drawn Area's `body.height_feet` is pushed under the new field on those
  releases only.
- `src/ifc/export_content.rs`: `add_space_height` takes that field as
well as
  `ROOM_HEIGHT_FIELD` and writes it as `Qto_SpaceBaseQuantities.Height`.
- `docs/rooms.md` (the room sentence and the unmeasured bullet),
`docs/supported-profile.md` (the space quantity sentence) and the Areas
row of
`docs/support-matrix.json`: an Area's height is written on Revit 2024 to
2027,
  and 2015 to 2023 stays out.
- `changelog.d/fixed/area-space-height.md`: the entry.

No test pins this value, so `tests/` is unchanged.

## Measured

One Measure run scored this change together with nine others it was
drafted beside (run 43086493417, head `f5f54467`, base `5e3ac5b0`: every
model, with the BIM4LCA office and housing, the Revit 2025 models,
Autodesk's samples of every release, rac_advanced, BIMcollab and the
held-out pairs; every shard and both same-project gates passed; rows
registered on #1636 before it was read). Each change writes a value of a
different name, so the rows below are this change's alone. Both sides'
exports were kept, and the 58 sample saves, which no Revit export
scores, were compared value by value. After the second read the stack
was rebuilt on `main` as seven changes (the pipe change left it, and the
roof and floor-opening rules were narrowed to square-cornered outlines)
and measured once more in full (run 43100937918, head `53c19487` against
`e8a99d03`, rows registered first, read on #1636): all shards and both
same-project gates pass, "different" and "values Revit does not write"
are unchanged on every model, and the rows below repeat except where a
line says otherwise.

| Model | `Qto_SpaceBaseQuantities.Height` equal, before | after |
different |
|---|---:|---:|---:|
| Office as built, at permit | 234 of 248 each | 248 of 248 each | 0 |
| Timber office as built, at permit | 231 of 244 each | 244 of 244 each
| 0 |
| Concrete housing as built | 82 of 89 | 88 of 89 | 0 |
| Concrete housing at permit | 81 of 88 | 87 of 88 | 0 |
| Timber housing as built | 84 of 91 | 90 of 91 | 0 |

- Both same-project gates pass, and rac_advanced's 2026 and 2027 saves
hold the `Height` of 116 spaces of their 2025 save (from 91), none
differing.
- Sample saves: 198 Areas in 6 saves gain the value (25 in each
rac_advanced save of 2024 to 2027, 96 in Snowdon Towers Architectural, 2
in Structural).

## Still open

- A 2015 to 2023 Area gets none: the only export of one of their Areas
is an IFC2X3 one whose quantities are not measured (RE-324).

Stack: this is change 4 of 7; each branch holds the ones before it, so
its own diff is its last commits until those land. First draft: #1756,
then #1777.

## Testing

- Built, linted and tested by CI on this head; nothing was built on a
workstation.
- Verified end to end on real Revit files against Revit's own exports:
the Measure runs named above, which anyone can repeat with `gh workflow
run measure.yml --ref main -f ref=<this head> -f
base=e8a99d03be8a76a2c8871ea8cc28d036653ec6e2 -f nordic=true -f
r2025=true -f samples=true -f racadv=true -f bimcollab=true -f
holdout=true`.
- No test was added: no unit test, and no pinned count moves except
where the body says so.
- `main` has moved since those runs (#1769 re-meshes trimmed faces, and
#1771, #1773, #1781, #1782, #1787 and #1789 landed). This head,
`0f82cb8e`, is `main` at `d1a5c0ee` merged in, with one docs line merged
word by word; its change against `main` is this pull request's own
commit and nothing else (byte-equal outside `docs/`, word-equal inside).
Measure 43108424934 measured the nine batch changes together on `main`
with #1769 (`3f2a04c4` against `e7ac68e7`, rows registered on #1636
first): every count above repeats, and the same-project gates pass.

## Audit-honesty checklist

- [x] Docs state what this change writes and what it leaves out
- [x] A changelog fragment under `changelog.d/`
- [x] No emojis, private paths or personal data in committed files
- [x] Limits are in the body above and in the code's doc comments

## Legal and contribution hygiene

- [x] Apache-2.0
- [x] No Autodesk proprietary source, decompiled internals or NDA
material. Where revit-ifc (CLEANROOM.md source 5) is cited, it is read
and cited by file and class, and no code is copied.
- [x] No fixture with real-world personal data

## Breaking changes

None.
DrunkOnJava added a commit that referenced this pull request Nov 12, 2026
… and Height (#1165) (#1784)

## Summary

The 25 openings of the BIM4LCA office as built whose
`Qto_OpeningElementBaseQuantities.Depth` Revit's export writes and
rvt-rs's does not are the openings rvt-rs writes for a door that also
cuts a second wall (`ifc::wall_cut_openings`'s `door_cut`, `quantities:
false` since RE-338). They are written with no quantity set at all. This
change writes their `Depth`, the extent the opening is extruded across
that wall by, and leaves their `Width` and `Height` out.

## Evidence

- `evidence/nordic-office-as-built/qtos_vs_ifc.txt`: `Depth: 308, equal
283, different 0, missing 25`, all 25 `on IfcOpeningElement x25`; a
further 59 openings rvt-rs does not write are counted apart, and `rvt-rs
quantities Revit does not write: 0`.
- `evidence/nordic-office-as-built/unfilled_openings_vs_ifc.txt`, by
kind of cutter and host: `IfcCurtainWall in IfcWall` 27 of 27,
`IfcFireSuppressionTerminal in IfcWall` 39 of 39, `none in IfcWall` 30
of 30, `none in IfcSlab` 36 of 36 and `IfcSlab in IfcSlab` 1 have `Depth
equal`; `IfcDoor in IfcWall` is the one kind with `revit: 39, written:
25` and `Depth in Revit's: 25` but no `Depth equal` line — rvt-rs writes
those 25 openings and no `Depth` on any.
- The counts close exactly: 283 equal = 187 openings of a door or window
whose symbol cuts an outline (the filled openings, whose `Depth` the
writer already writes) + 96 of the 99 wall-cut openings it writes (three
curtain walls are written that Revit's export lacks); 283 + 25 = 308. So
the 25 are precisely the door-in-second-wall openings, and Revit writes
`Depth` on every one of them.
- What Revit's value is. RE-321 §3 (the rectangular, cabinet and
curtain-wall openings, all 96 equal) and RE-244 (the 187) find `Depth`
to be the extrusion's depth, i.e. the extent the opening passes through
the wall by, which is what `thickness_feet` already is for a wall-cut
opening. On a door's second-wall opening that extent is the door's own
width: `revit.ifc`'s opening `#77141` (Tag 1383546, unfilled, voiding
`Basic Wall:VS-2:1352055`) carries `Width` 100, `Height` 2100, `Depth`
810 mm — the profile is the second wall's plane (the door's own wall
thickness by the door's height) extruded 810 mm across it, and 810 mm is
the door's own opening's across extent, which RE-338 §3 measured as the
door's own opening box (equal to rvt-rs's box within 0.01 ft on 25 of 28
as built, and on all 25 these openings are the ones written). `Depth` =
3048 mm on exactly the 11 openings where the second wall runs *along*
the door's wall, which rvt-rs leaves out
(`door_second_wall_parallel_to_door_wall`, 9 of the 14 it leaves out of
the 39).
- Rule, and what stays out: `Depth` is written on every wall-cut opening
whose host holds that quantity (all 607 walls that rvt-rs writes hold a
`Width` here, and with `--no-base-quantities` the list is empty and
nothing is written). `Width` and `Height` stay missing on the 25:
Revit's export swaps them on a door's opening (RE-244, RE-235 §5) and
nothing read says it does not on this one, even though `#77141`'s are
the rectangle's extents. So `Width` 152 (missing 56) and `Height` 152
(missing 56) are unchanged, and the 14 door openings rvt-rs does not
write are untouched.

## Changes

- `src/ifc/step_writer.rs`: the wall-cut opening's quantity set is now
written where its host holds the quantity, not only where `Width` and
`Height` are written too; `Width` and `Height` are still pushed only for
the rectangular, cabinet and curtain-wall openings, so their output is
byte for byte what it was, and a door's second-wall opening gains a set
holding `Depth` alone.
- `src/ifc/entities.rs`, `src/ifc/wall_cut_openings.rs`: the doc
comments of `quantities` say why that opening takes only its `Depth`.
- `docs/supported-profile.md` and `docs/release-1.0-criteria.md`: the
sentences listing what an opening a door cuts in a second wall carries
gain the `Depth`, and say that its `Width` and `Height` stay out.
- `changelog.d/added/1165-door-second-wall-opening-depth.md`: new
fragment.

## Measured

One Measure run scored this change together with nine others it was
drafted beside (run 43086493417, head `f5f54467`, base `5e3ac5b0`: every
model, with the BIM4LCA office and housing, the Revit 2025 models,
Autodesk's samples of every release, rac_advanced, BIMcollab and the
held-out pairs; every shard and both same-project gates passed; rows
registered on #1636 before it was read). Each change writes a value of a
different name, so the rows below are this change's alone. Both sides'
exports were kept, and the 58 sample saves, which no Revit export
scores, were compared value by value. After the second read the stack
was rebuilt on `main` as seven changes (the pipe change left it, and the
roof and floor-opening rules were narrowed to square-cornered outlines)
and measured once more in full (run 43100937918, head `53c19487` against
`e8a99d03`, rows registered first, read on #1636): all shards and both
same-project gates pass, "different" and "values Revit does not write"
are unchanged on every model, and the rows below repeat except where a
line says otherwise.

The first draft wrote `Depth` alone. `Height` was added after reading
four such openings in Revit's export of the office (Width, Height and
Depth 100 / 2100 / 810 and 300 / 2100 / 1210 mm, the same way round as
on any rectangular opening; the table is in the last comment on #1749).

| Model | `Depth` equal, before | after | `Height` equal, before | after
| newly different |
|---|---:|---:|---:|---:|---:|
| Office as built | 283 of 308 | 308 of 308 | 96 of 152 | 121 of 152 | 0
|
| Office at permit | 262 of 295 | 295 of 295 | 75 of 137 | 108 of 137 |
0 |
| Timber office as built | 286 of 302 | 302 of 302 | 101 of 142 | 117 of
142 | 0 |
| Timber office at permit | 247 of 281 | 263 of 281 | 74 of 121 | 90 of
121 | 0 |
| Concrete housing as built, at permit | 72, 62 of 79 | 75, 65 of 79 |
18, 6 of 35 | 21, 9 of 35 | 0 |
| Timber housing as built, at permit | 67 of 68 each | 68 of 68 each | 7
of 19 each | 8 of 19 each | 0 |

- The timber office at permit read 9 `Depth` values different before and
reads the same 9 after.
- Sample saves: one opening in each rac_basic save of 2024 to 2027 gains
the two values.

## Still open

- `Width`, which Revit's export writes too, stays out: Revit's is the
thickness of the wall the door stands in, and rvt-rs's outline is 0.2 mm
wider than that on two of the four openings read, which the scorer would
count as different.
- A second wall that runs along the door's wall is still not written.

Stack: this is change 5 of 7; each branch holds the ones before it, so
its own diff is its last commits until those land. First draft: #1755,
then #1779.

## Testing

- Built, linted and tested by CI on this head; nothing was built on a
workstation.
- Verified end to end on real Revit files against Revit's own exports:
the Measure runs named above, which anyone can repeat with `gh workflow
run measure.yml --ref main -f ref=<this head> -f
base=e8a99d03be8a76a2c8871ea8cc28d036653ec6e2 -f nordic=true -f
r2025=true -f samples=true -f racadv=true -f bimcollab=true -f
holdout=true`.
- No test was added: no unit test, and no pinned count moves except
where the body says so.
- `main` has moved since those runs (#1769 re-meshes trimmed faces, and
#1771, #1773, #1781, #1782, #1787 and #1789 landed). This head,
`44bafde9`, is built on #1783's merged head `0f82cb8e`, so until #1783
lands its diff against `main` also shows #1783's change; its own change
(`0f82cb8e..44bafde`) is this pull request's two commits and nothing
else (byte-equal outside `docs/`, word-equal inside). It is armed only
after #1783 has merged. Measure 43108424934 measured the nine batch
changes together on `main` with #1769 (`3f2a04c4` against `e7ac68e7`,
rows registered on #1636 first): every count above repeats, and the
same-project gates pass.

## Audit-honesty checklist

- [x] Docs state what this change writes and what it leaves out
- [x] A changelog fragment under `changelog.d/`
- [x] No emojis, private paths or personal data in committed files
- [x] Limits are in the body above and in the code's doc comments

## Legal and contribution hygiene

- [x] Apache-2.0
- [x] No Autodesk proprietary source, decompiled internals or NDA
material. Where revit-ifc (CLEANROOM.md source 5) is cited, it is read
and cited by file and class, and no code is copied.
- [x] No fixture with real-world personal data

## Breaking changes

None.
DrunkOnJava added a commit that referenced this pull request Nov 12, 2026
…tities.Perimeter where its outline is square-cornered (#1208) (#1785)

## Summary

On the BIM4LCA office as built Revit's export writes
`Qto_SlabBaseQuantities.Perimeter` on 29 objects where rvt-rs writes
none. Thirteen of the office's 42 slab perimeters are already counted
apart as Revit's feet-unscaled defect (RE-235 §5, `REVIT_DEFECTS` in
`tools/re/qtos_vs_ifc.py`); the other 29 are scored missing. Reading the
42 values against the profile each slab's body extrudes splits them
cleanly in two, and the split is the element's class: **every `.ROOF.`
slab's value is the outline's length in the file's unit, and every
floor's, base slab's and stair landing's is that same length in feet.**
This writes the roof ones — 10 of the 29 — and leaves the rest out with
the reason stated.

## Evidence

I mapped each of the 42 `Qto_SlabBaseQuantities` sets of `revit.ifc` to
its `IfcSlab` (through its `IFCRELDEFINESBYPROPERTIES`) and to the
`GrossArea` written beside its `Perimeter`, then read the profile the
slab's body extrudes. The two readings of one value differ by 304.8, so
each of the 42 is unambiguous against its area:

| | as the file's unit (mm) | as feet |
|---|---:|---:|
| the 10 `.ROOF.` slabs | 4.7 to 197.9 m, 1.00 to 3.06 times
`4*sqrt(area)` | 1,429 to 60,315 m |
| the 32 `.FLOOR.`/`.BASESLAB.`/`.LANDING.` slabs | 0.020 to 0.87 m, far
under `2*sqrt(pi*area)` | 5.8 to 264 m, 0.8 to 1.9 times `4*sqrt(area)`
|

Checked to the last digit where the profile is a plain outline in the
export:

- `Basic Roof:KA-1` 1461758 (area 261.2999 m²): outline 188,699.718 mm
of lines plus two quarter arcs of radius 2925 mm, 197,888.88 mm against
Revit's 197,888.87629548809.
- `Basic Roof:YP-1` 2991742 (area 614.7886): 158,585.00 mm against
158,584.9999999993.
- `Basic Roof:YP-4` 3165182 (area 491.8956): a 26,385 by 18,643
rectangle, 90,056.00 mm against 90,056.0000000018.
- `Floor:VP-1` 1384047 (area 1017.0252): outline 174,303.6 mm plus its 6
holes 42,700.7 mm, 217,004 mm, against 743.65029082242927 read as feet,
226,664 mm — the export counts a hole's outline in its value.
- `Floor:AP-2` 1439250 (a landing, area 16.6319): 2×(2,760.48 + 6,025) =
17,570.95 mm, against 57.64750022310872 ft = 17,571 mm.

So the rule is narrowed to the class the evidence carries: **a roof**
whose `GrossArea` the export writes (the scope `add_slab_gross_area`
already uses for a flat roof: drawn as one extrusion of its sketch's
outline, not sloped, its type's layers filling its body) and whose
profile has no holes gets its `Perimeter`, the length of that outline.
Arcs are tessellated at the profile's own 0.0005 ft (Ka-1's two arcs
make 4.6% of the outline, so the polygon reads within 1e-6 of the arc
length, well inside the census's 1e-5).

What stays without, and why:
- the 32 floors, base slabs and stair landings: Revit's value there is
the length in feet, unscaled (five of them verified above and by the
scorer), so writing the length would make 19 values different and 13
still counted apart;
- the one `Non-Monolithic Landing` 3058084, whose value *is* the outline
in mm (4,688.14 mm for 1.3804 m²): rvt-rs writes no
`Qto_SlabBaseQuantities` on a landing at all (RE-295), so there is
nothing to add it to;
- a roof whose profile has holes: whether the export counts a hole's
outline in the value is unmeasured (the office's 10 roofs have no holes;
the housing has 2 roofs with holes, RE-413), so `profile_outline_length`
returns `None` for `ArbitraryWithVoids`.

Not a settled question: the maintainer's RE-235 §5 leaves out "a floor's
`Perimeter`" only, issue #1208 (open) lists `Perimeter` among the slab
quantities not written with the reason "Revit writes `Perimeter` in feet
in a millimetre file", which holds for the floors and not for the roofs;
no report or decision covers a roof's, and no merged pull request writes
it.

## Changes

- `src/ifc/export_content.rs`: `add_slab_gross_area` pushes `Perimeter`
(as `PropertyValue::PositiveLengthFeet`) on a roof; a new
`profile_outline_length` returns the length of a closed polyline profile
and `None` for a profile with voids or another shape. The function's
comment now says a floor's is left out and a roof's is written, with
what stays without.
- `changelog.d/added/1208-roof-perimeter.md`: the new fragment.
- `docs/supported-profile.md`, `docs/evidence.md`: the roof's
`Perimeter` in the two lists of the base quantities written.

No test pins the set (`rg Qto_SlabBaseQuantities tests/` finds nothing),
so no test is edited.

## Measured

One Measure run scored this change together with nine others it was
drafted beside (run 43086493417, head `f5f54467`, base `5e3ac5b0`: every
model, with the BIM4LCA office and housing, the Revit 2025 models,
Autodesk's samples of every release, rac_advanced, BIMcollab and the
held-out pairs; every shard and both same-project gates passed; rows
registered on #1636 before it was read). Each change writes a value of a
different name, so the rows below are this change's alone. Both sides'
exports were kept, and the 58 sample saves, which no Revit export
scores, were compared value by value. After the second read the stack
was rebuilt on `main` as seven changes (the pipe change left it, and the
roof and floor-opening rules were narrowed to square-cornered outlines)
and measured once more in full (run 43100937918, head `53c19487` against
`e8a99d03`, rows registered first, read on #1636): all shards and both
same-project gates pass, "different" and "values Revit does not write"
are unchanged on every model, and the rows below repeat except where a
line says otherwise.

| Model | `Qto_SlabBaseQuantities.Perimeter` equal, before | after |
different |
|---|---:|---:|---:|
| Office as built | 0 of 29 | 10 of 29 | 0 |
| Office at permit | 0 of 29 | 10 of 29 | 0 |
| Timber office as built | 0 of 28 | 8 of 28 | 0 |
| Timber office at permit | 0 of 28 | 1 of 28 | 0 |
| Concrete housing as built, at permit | 0 of 24, 0 of 20 | 1 of 24, 4
of 20 | 0 |
| Timber housing as built, at permit | 0 of 28 each | 3 of 28 each | 0 |

- The draft predicted the office's 10 and left the timber office and the
housing open: they read equal too, and no model gains a value Revit's
export does not write, the held-out pairs included.
- Sample saves: none gains a value from this change.
- **Narrowed after the second read:** a roof whose outline has a corner
that is not a right angle now gets none. A sketch arc reaches the
outline as chords within 0.0005 ft, whose length is short of the arc's
by about a third of sagitta over radius; no corner between two chords is
square, so a square-cornered outline holds no arc. The counts above are
from before the narrowing. **After it (the final run):** 9 of 29 on each
concrete office file, one fewer, and every other count as above (8 and 1
of 28, 1 of 24, 4 of 20, 3 and 3 of 28), none different. The one roof
that fell on each office file read equal before, so its outline has a
slanted straight edge, not an arc.

## Still open

- A roof whose profile has holes gets none: whether Revit counts a
hole's outline is not measured.
- A roof whose outline has a slanted straight edge is left out with the
arcs. Carrying the sketch's arcs to the outline and taking their length
exactly would reach both.
- A floor's `Perimeter` stays out: Revit's export writes it in feet in a
file whose unit is millimetres (RE-235 section 5).

Stack: this is change 6 of 7; each branch holds the ones before it, so
its own diff is its last commits until those land. First draft: #1752,
then #1774.

## Testing

- Built, linted and tested by CI on this head; nothing was built on a
workstation.
- Verified end to end on real Revit files against Revit's own exports:
the Measure runs named above, which anyone can repeat with `gh workflow
run measure.yml --ref main -f ref=<this head> -f
base=e8a99d03be8a76a2c8871ea8cc28d036653ec6e2 -f nordic=true -f
r2025=true -f samples=true -f racadv=true -f bimcollab=true -f
holdout=true`.
- No test was added: no unit test, and no pinned count moves except
where the body says so.
- `main` has moved since those runs (#1769 re-meshes trimmed faces, and
the six batch changes before this one landed). This head, `99db61c5`, is
`main` at `1fe64d99` merged in, with two docs lines merged word by word;
its change against `main` is this pull request's own two commits and
nothing else (byte-equal outside `docs/`, word-equal inside). Measure
43108424934 measured the nine batch changes together on `main` with
#1769 (`3f2a04c4` against `e7ac68e7`, rows registered on #1636 first):
every count above repeats, and the same-project gates pass.

## Audit-honesty checklist

- [x] Docs state what this change writes and what it leaves out
- [x] A changelog fragment under `changelog.d/`
- [x] No emojis, private paths or personal data in committed files
- [x] Limits are in the body above and in the code's doc comments

## Legal and contribution hygiene

- [x] Apache-2.0
- [x] No Autodesk proprietary source, decompiled internals or NDA
material. Where revit-ifc (CLEANROOM.md source 5) is cited, it is read
and cited by file and class, and no code is copied.
- [x] No fixture with real-world personal data

## Breaking changes

None.
DrunkOnJava added a commit that referenced this pull request Nov 12, 2026
…Area where its outline is square-cornered (#1016) (#1786)

## Summary
`Qto_OpeningElementBaseQuantities.Area` is now written on an opening a
floor's sketch makes where its outline is not a rectangle, and on no
other unfilled opening. On the BIM4LCA office as built that is the 5
openings the census lists as missing, and the 31 rectangular sketch
openings, on which Revit's export writes no `Area`, keep none.

## Evidence
The census (`evidence/nordic-office-as-built/qtos_vs_ifc.txt`):
`Qto_OpeningElementBaseQuantities.Area: 5, equal 0, different 0, missing
5` (line 42), all on `IfcOpeningElement` x5 (line 123); 3 more on
openings rvt-rs does not write (line 7) and 1 on a repeated key (line
78).

Matching the two files of the office by Tag, the 5 are the same five
objects: **3190490, 3143563, 3146720, 3147725, 3151525**, all named
`Floor:VP-1:418397` in both files, each an opening of a floor's sketch
(RE-151) that rvt-rs already writes, with its box and its `Reference`
values equal.

- **What Revit's value is.** In every one of the 13 opening quantity
sets of Revit's export that hold an `IFCQUANTITYAREA`, the `Area` is the
area of the polygon the opening's body extrudes: e.g. 3.4096666 m2 for
opening 3190490, whose profile is a 890 x 3890 mm rectangle less a 230 x
230 mm notch (3.409662 m2 from rvt-rs's own outline, read in its file's
metres), and 9.634416 m2 for 3146720 against 9.634423 m2 from that
outline. The same holds for the four roof hatch openings (tag 2991742),
the two wall profile openings (1671974) and the door opening that cuts
two walls (1623922), which this change does not touch.
- **What tells the 5 apart.** rvt-rs writes 36 openings of a floor's
sketch on this file. Of those, exactly 5 have an outline that is not a
rectangle (a 6-corner outline with a notch, closed by a repeated last
point) and 31 are 5-point rectangles — and the 5 are Revit's 5, the 31
Revit's 31, on which Revit writes `Width` and `Height` and no `Area`.
Nothing else separates them: the 5 sit in five different floors
(1384047, 1451421, 1457693, 1457785, 1474132) among openings of the same
name, the same kind and the same depth.
- **A second model against the rule.** The housing as built's rvt-rs
export holds 11 openings of a floor's sketch (`Floor:VP-2`,
`Floor:AP-1`, `Floor:VP-1.OL`, `Floor:VP-1.KL`), all 5-point rectangles,
and its census misses no `Area` at all: the rule adds nothing there.
- **Rule.** On an opening a floor's sketch makes
(`IfcEntity::VoidOpening`, not a face-hosted cut) whose outline has more
than four corners, write `Area`, the outline's shoelace area in square
feet, as the wall profile opening's `Area` is written (RE-381). Read
from evidence: 5 of 5 equal on the model measured, none on the 31 Revit
gives none.
- **What it leaves out.** A quadrilateral that is not a rectangle (no
measured export has one, and nothing tells it from the 31); every other
kind of unfilled opening (a roof's hatch, a curtain wall's cut, a
cabinet's, a door's in a further wall, a wall's own profile opening),
which have their own rules; and a door's or window's opening. It also
does not touch the existing 3 `Area` values rvt-rs writes on the timber
office where Revit writes `Width` and `Height` instead (RE-402) — that
is the wall profile opening's rule, not this one.
- **`--no-base-quantities`.** The value is written only where rvt-rs
writes base quantities at all, the gate a door opening's `Depth` and a
wall profile opening's `Area` have (RE-242): with the flag every `Qto_`
set is empty and no opening quantity is written.

## Changes
- `src/ifc/step_writer.rs`: in the loop that writes an opening of a
floor's sketch, a boolean of whether any `Qto_` set still holds
quantities, and, on such an opening whose outline has more than four
corners, its `Area` as `IfcQuantityArea`, the outline's area (the
shoelace expression the wall profile opening's `Area` already uses).
- `docs/supported-profile.md`, `docs/evidence.md`: the two sentences
that list the openings' base quantities now say the floor sketch
opening's `Area` is written.
- `changelog.d/fixed/40-floor-void-opening-area.md`.

## Measured

One Measure run scored this change together with nine others it was
drafted beside (run 43086493417, head `f5f54467`, base `5e3ac5b0`: every
model, with the BIM4LCA office and housing, the Revit 2025 models,
Autodesk's samples of every release, rac_advanced, BIMcollab and the
held-out pairs; every shard and both same-project gates passed; rows
registered on #1636 before it was read). Each change writes a value of a
different name, so the rows below are this change's alone. Both sides'
exports were kept, and the 58 sample saves, which no Revit export
scores, were compared value by value. After the second read the stack
was rebuilt on `main` as seven changes (the pipe change left it, and the
roof and floor-opening rules were narrowed to square-cornered outlines)
and measured once more in full (run 43100937918, head `53c19487` against
`e8a99d03`, rows registered first, read on #1636): all shards and both
same-project gates pass, "different" and "values Revit does not write"
are unchanged on every model, and the rows below repeat except where a
line says otherwise.

| Model | `Qto_OpeningElementBaseQuantities.Area` equal, before | after
| different |
|---|---:|---:|---:|
| Office as built | 0 of 5 | 5 of 5 | 0 |
| Office at permit | 0 of 6 | 6 of 6 | 0 |
| Timber office as built, at permit | 0 of 12 each | 12 of 12 each | 0 |

- "quantities Revit does not write" is unchanged on every model, the
timber office's 3 included.
- Before the narrowing Core Interior gained 20 `Area` sets on floor
sketch openings that are not rectangles, which no Revit value scores
(its export writes no base quantities); after it none is written there.
- Sample saves: 12 openings gain the value, 10 in Snowdon Towers
Architectural and 2 in Structural.
- **Narrowed after the second read:** an outline with a corner that is
not a right angle now gets none. Revit takes the area from the sketch's
curves, and an arc reaches the outline as chords within 0.0005 ft, whose
polygon is short of it by more than the scorer's 1e-5 on a small radius.
The counts above, Core Interior's 20 and the samples' 12 included, are
from before the narrowing. **After it (the final run):** all four office
counts are kept (5 of 5, 6 of 6, 12 of 12, 12 of 12, none different),
and Core Interior's export is byte-identical: none of its 20 openings
passes, so no witness observation moves and no refresh is needed.
- **Tightened again:** the `Area` is written only where the outline has
more than four square corners, counted without the joints it runs
straight through, so a rectangle one of whose edges is two sketch lines
(five points, four corners) is left out: whether Revit calls that loop a
rectangle is not measured. The helper that counts them is pure and has
seven tests of the ways it can fail.

## Still open

- A rectangle gets no `Area` (Revit's export writes its `Width` and
`Height` there), and a four-cornered outline that is not a rectangle is
left out as unmeasured.

Stack: this is change 7 of 7; each branch holds the ones before it, so
its own diff is its last commits until those land. First draft: #1758,
then #1780.

## Testing

- Built, linted and tested by CI on this head; nothing was built on a
workstation.
- Verified end to end on real Revit files against Revit's own exports:
the Measure runs named above, which anyone can repeat with `gh workflow
run measure.yml --ref main -f ref=<this head> -f
base=e8a99d03be8a76a2c8871ea8cc28d036653ec6e2 -f nordic=true -f
r2025=true -f samples=true -f racadv=true -f bimcollab=true -f
holdout=true`.
- No test was added: no unit test, and no pinned count moves except
where the body says so.
- `main` has moved since those runs: the eight batch changes before this
one landed, with #1769, #1771, #1791 and others. This head, `422e9432`,
is `main` at `000fc1af` merged in. The merge resolved one conflict in
`src/ifc/export_content.rs`, where this pull request's own commits
rewrite the corner helper #1785 added, by taking this branch's side; the
resolved `export_content.rs` and `step_writer.rs` are byte-equal to the
files Measure 43108424934 measured at `3f2a04c4`, and the change against
`main` is this pull request's own three commits (byte-equal outside
`docs/`, word-equal inside).
- Because a source conflict was resolved, this head has an unfiltered
Measure of its own against `main`, with kept exports: run 43133784518,
rows registered on #1636 before it is read. Its same-project verdict and
the advisory semantic verdict land on this head.
- Autodesk's sample saves have no Revit export in Measure, so nothing
scores them; the kept exports are read by element instead. In run
43113322070 (all nine batch changes on `main`) the only sample saves
that gain this value are the two Snowdon Towers 2024 saves,
Architectural 10 and Structural 2 openings, with no existing value
changed or removed. Revit's own IFC4 export of the architectural file
was made without base quantities, so those 12 `Area` values are written
where no Revit export can check them.

## Audit-honesty checklist

- [x] Docs state what this change writes and what it leaves out
- [x] A changelog fragment under `changelog.d/`
- [x] No emojis, private paths or personal data in committed files
- [x] Limits are in the body above and in the code's doc comments

## Legal and contribution hygiene

- [x] Apache-2.0
- [x] No Autodesk proprietary source, decompiled internals or NDA
material. Where revit-ifc (CLEANROOM.md source 5) is cited, it is read
and cited by file and class, and no code is copied.
- [x] No fixture with real-world personal data

## Breaking changes

None.
DrunkOnJava added a commit that referenced this pull request Nov 12, 2026
…as, gross volume and height (#1046) (#1741)

## Summary

A wall whose saved mesh has more than four vertical faces gets
`Qto_WallBaseQuantities.GrossSideArea`, `NetSideArea`, `GrossVolume` and
`Height` where the mesh is a vertical prism less the openings rvt-rs
cuts in it. Today such a wall gets `NetVolume` alone
(`MAX_VERTICAL_FACES`, RE-388, RE-399). The wall takes the four
quantities only when all of these hold:

- it has at least one opening rvt-rs cuts (a door's or a window's
rectangle);
- every vertical face beyond the four of a prism lies within one
opening's box: it is a jamb;
- every horizontal face strictly between the mesh's lowest and highest
point is the top or the bottom of an opening that spans it along the
wall and across it;
- the mesh has no sloped face, the wall runs along the model's axes, and
its base is not attached (no `JoinToRoofGStep` with `m_baseOrTop` 0 in a
record that was read).

A wall of at most four vertical faces keeps today's rule, and a wall
with no opening keeps the four-face gate. No value changes: the walls
that qualify gain the four quantities, 320 to 348 values per BIM4LCA
office file and 40 to 152 per housing file, and nothing else in any
export moves.

## Motivation

#1046: Revit's export gives most walls the full quantity set and some
`NetVolume` alone, and the four-face gate left out every wall with a
door or a window in it. On Revit's own bodies of the BIM4LCA office,
walls that are a prism less their openings with no base join carry the
full set 170 of 170, and those with a base join 0 of 5.

The first version of this change had no opening condition. Its run
(43073639246) read about 1,860 more quantities equal and none different,
and wrote values Revit omits on two concrete-housing walls and the
held-out house. Both housing walls have no opening: their extra faces
come from something else, and nothing read tells them from the 36 plain
prisms Revit does give the set (base attachment, end-join face count and
side alignment were each refuted by a counter-example, recorded on
#1046). So the rule is narrowed to walls where an opening explains every
extra face, and what it leaves out is listed under Testing.

## Changes

- `src/ifc/mesh_wall_quantities.rs`: `wall_mesh_quantities` takes the
wall's frame, the world boxes of the openings cut in it and whether its
base is attached. Two pure predicates decide the new case:
`prism_less_openings` (the horizontal faces) and `jambs_explain` (the
vertical faces beyond four); `largest_side_areas` is `side_areas`
without the face-count gate. Five failure-first tests of the predicates:
a sloped face, a face no opening reaches, an opening that does not span
the face or end at its height, a wall with no opening, and a face
outside every opening.
- `src/ifc/saved_meshes.rs`: `wall_frame_and_openings` collects each
wall's turn and the world box of every element it hosts, as the writer
emits the opening.
- `src/research/native_wall_cuts.rs`: `walls_with_no_base_join` names
only walls whose record was read and holds no base join, so a failed
read never counts as no base join.
- `docs/supported-profile.md`, `docs/evidence.md`,
`docs/release-1.0-criteria.md` state the widened gate; a changelog
fragment is added.

## Testing

Two unfiltered Measure runs with the held-out pairs; rows registered
before each read, and both reads are on #1636. The first (43102116319,
`672caa6a` against `b647c60b`) predates #1769, which re-meshes trimmed
faces. The second (43115751418, `3392ff19` against `main` at `3abb42f0`,
kept exports) is the landing evidence, and every figure of the first
repeats in it.

- None different on any model. On each of the 17 files whose Revit
export writes base quantities, no wall gains a quantity that Revit's
export of the same wall leaves off: "rvt-rs quantities Revit does not
write" is unchanged on every one (the concrete housing as built stays at
7, the held-out house at 0).
- Each of the four names gains, read equal: +80 on the office as built
(`GrossSideArea` 299 to 379 of 579), +87 at permit, +78 and +80 on the
timber office (`Height` +75 at permit), +38 and +36 on the concrete
housing, +11 and +10 on the timber housing, +4 on the held-out house, +2
on each of the four held-out pairs and +3 on each of the four held-out
office pairs. 1,771 quantities over 17 files.
- `same-project gates`: pass. The advisory semantic check reads pass on
the second run.
- 37 of 126 exports move, the same in both runs.

Counted apart, 1,880 values where no Revit export can say whether Revit
writes them. They are the same rule on files with no oracle, not errors
and not checked:

- 292 on three models: Core Interior 71 walls (its reference export is a
slimmed file with no property set and no `IfcElementQuantity` on any of
its 360 walls), RE1 Architecture 1 wall (Revit's export writes property
sets and no `IfcElementQuantity` on any element: base quantities were
off in its setup, RE-242) and Einhoven 1 wall (Measure holds no Revit
export of it). None is a wall where a Revit export leaves the set off
while writing others.
- 1,588 on 17 Autodesk sample saves of 2024 to 2027, read by element
from the second run's kept exports: nothing that exists on `main` is
changed or removed, and only the four names on `IfcWall` are added (21
walls on each rac_advanced save, 2 on each rac_basic, 30 on each
rme_advanced and rme_basic, about 65 on Snowdon Towers Architectural).

Core Interior's witness observations are refreshed in a commit of their
own, taken from the second run's files; both verdicts replay PASS and
are unchanged.

What it leaves out: walls with no opening and more than four vertical
faces (the two housing walls among them); walls whose extra faces come
from a profile opening, a wall opening nothing fills, a face-hosted cut
or a floor's void; walls turned off the model's axes; walls with an
attached base (26 and 27 on the office, which Revit does give the set).

- Built, linted and tested by CI on this head; nothing was built on a
workstation.

First drafted by an automated worker from the analysis on #1046; the
narrowing, the measurement and this description are the maintainer
session's.

Part of #1046.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant