Skip to content

feat(ifc): write IfcRailing's PredefinedType from the railing's own or its type's value (#1713) - #1729

Closed
DrunkOnJava wants to merge 1 commit into
mainfrom
pilot/07-railing-predefined
Closed

DrunkOnJava wants to merge 1 commit into
mainfrom
pilot/07-railing-predefined

Conversation

@DrunkOnJava

Copy link
Copy Markdown
Owner

Summary

Revit's export gives every IfcRailing a PredefinedType; rvt-rs wrote $ on all 378 railings of the 42 models with a Revit export (#1713). This adds IFCRAILING to category_map::PREDEFINED_TYPE_ENUMERATORS with the IFC4 IfcRailingTypeEnum enumerators, so a railing takes its own or its type's "IFC Predefined Type" where that value is an enumerator of the entity — the same rule RE-45 and RE-419 already apply to slabs, coverings, shading devices, roofs, the waste, electric, fire-suppression, sanitary and air terminals, and furniture. Nothing else changes: the Railing mapping keeps no default, and category_map::predefined_type_left_out still keeps the occurrence's value off a Revit 2027 save (#1692).

Evidence

What Revit writes. The office's own IFC4 export (revit.ifc) holds 41 IFCRAILING, and rvt-rs's export of the same file holds the same 41 by Tag, each with $ in the last attribute. Tabulated by the type name (the text before the last colon of Name) and the last attribute:

type railings Revit's PredefinedType
KAI-4 10 HANDRAIL
KJO-1 22 HANDRAIL
KAI-1 1 GUARDRAIL
KAI-2 2 GUARDRAIL
KAI-3 2 GUARDRAIL
KAI-5 3 GUARDRAIL
KAI-6 1 NOTDEFINED

32 HANDRAIL, 8 GUARDRAIL, 1 NOTDEFINED, and every railing of a type has that type's value: 7 types, 7 values.

What does not decide it. Not the name: KAI-4 is HANDRAIL and KAI-1 is GUARDRAIL, and KAI-6 is NOTDEFINED. Not the host: RE-390 counts 26 of the office's railings naming a stair and 8 naming a ramp, where 32 are HANDRAIL, so a stair-hosted railing is not the rule and a ramp-hosted one is not either.

What does. A value that is constant per railing type is the type's own, which is what RE-45's "IFC Predefined Type" reads (the instance's, else its type's, ExportParameters::effective_predefined_type). RE-190 measured 40 IfcRailing export-parameter values in the office's railings' data objects, so the office's railings do carry IFC export parameters, and attach_ifc_export_overrides already attaches them to the railing as m_ifc_predefined_type; the only thing that kept the value out of the export was that IFCRAILING was not in the enumerator table, so predefined_type_for returned None and the mapping's own None was written. The mechanism is proven on other classes: RE-419 reads 872 of 884 furniture equal to Revit's with none different, and RE-190 78 of 78 waste terminals, 51 of 51 electric appliances, 40 of 40 fire-suppression terminals, 15 of 15 sanitary terminals and 1 of 1 air terminal. revit-ifc's IFCExportInfoPair keeps a value that is an enumerator of the entity and defaults the rest (RE-419, cited by class, CLEANROOM.md source 5).

What stays $. A railing with no "IFC Predefined Type" of its own or its type's, and one whose value is not an IfcRailingTypeEnum enumerator. I did not add the NOTDEFINED default RE-419 gave furniture: the only railing measured with NOTDEFINED is the office's one KAI-6, and I cannot tell whether its type carries the value or nothing, so a default would write NOTDEFINED where Revit writes HANDRAIL on any file whose export parameters are not read (Revit 2023 and earlier, where attach_ifc_export_overrides does not run). On the office that leaves at most that one railing unset; on the other 41 models the railings whose types carry no value stay unset too. A Revit 2027 save keeps none, through predefined_type_left_out.

Changes

No test is edited. tests/railing_type.rs finds the railing by the last quoted attribute of its IFCRAILING line, which is the Tag before and after this change, and the type object's Tag likewise.

What was not checked

  • I could not compile or run anything, so CI's build, clippy and the real-file tests are the first check of the edit.
  • I could not read the .rvt, so I have not seen the office's railing types' "IFC Predefined Type" and cannot show that its value equals Revit's on any railing. The rule rests on the per-type correlation above and on the mechanism RE-45, RE-190 and RE-419 proved on other classes. The measurement must confirm differs 0 and unset in rvt-rs 0 on the office's 41 railings, and must say how many of the 378 railings of the 42 models still read unset (the ones whose types carry no value, and the NOTDEFINED ones).
  • The type objects: rvt-rs writes 7 IfcRailingType where Revit's export of the office writes none, so their new PredefinedType has no oracle; predefined_types_vs_ifc.py scores a type class only where both files hold it.
  • Only one model of the evidence has both IFC files, so the rule is measured on one project in one state; the housing and timber models have no Revit export here.

Pilot draft: written by an automated worker and pushed as proposed, with rustfmt applied. Not yet read by a maintainer session; please do not review, approve or arm it.

@DrunkOnJava

Copy link
Copy Markdown
Owner Author

Superseded by #1765: the same commit on a fresh branch, with the measured rows in its body.

DrunkOnJava added a commit that referenced this pull request Nov 11, 2026
…1713) (#1765)

## Summary

Revit's export gives every `IfcRailing` a `PredefinedType`; rvt-rs wrote
`$` on all 378 railings of the 42 models with a Revit export (#1713).
This adds `IFCRAILING` to `category_map::PREDEFINED_TYPE_ENUMERATORS`
with the IFC4 `IfcRailingTypeEnum` enumerators, so a railing takes its
own or its type's "IFC Predefined Type" where that value is an
enumerator of the entity — the same rule RE-45 and RE-419 already apply
to slabs, coverings, shading devices, roofs, the waste, electric,
fire-suppression, sanitary and air terminals, and furniture. Nothing
else changes: the `Railing` mapping keeps no default, and
`category_map::predefined_type_left_out` still keeps the occurrence's
value off a Revit 2027 save (#1692).

## Evidence

**What Revit writes.** The office's own IFC4 export (`revit.ifc`) holds
41 `IFCRAILING`, and rvt-rs's export of the same file holds the same 41
by `Tag`, each with `$` in the last attribute. Tabulated by the type
name (the text before the last colon of `Name`) and the last attribute:

| type | railings | Revit's `PredefinedType` |
|---|---:|---|
| `KAI-4` | 10 | `HANDRAIL` |
| `KJO-1` | 22 | `HANDRAIL` |
| `KAI-1` | 1 | `GUARDRAIL` |
| `KAI-2` | 2 | `GUARDRAIL` |
| `KAI-3` | 2 | `GUARDRAIL` |
| `KAI-5` | 3 | `GUARDRAIL` |
| `KAI-6` | 1 | `NOTDEFINED` |

32 `HANDRAIL`, 8 `GUARDRAIL`, 1 `NOTDEFINED`, and every railing of a
type has that type's value: 7 types, 7 values.

**What does not decide it.** Not the name: `KAI-4` is `HANDRAIL` and
`KAI-1` is `GUARDRAIL`, and `KAI-6` is `NOTDEFINED`. Not the host:
RE-390 counts 26 of the office's railings naming a stair and 8 naming a
ramp, where 32 are `HANDRAIL`, so a stair-hosted railing is not the rule
and a ramp-hosted one is not either.

**What does.** A value that is constant per railing type is the type's
own, which is what RE-45's "IFC Predefined Type" reads (the instance's,
else its type's, `ExportParameters::effective_predefined_type`). RE-190
measured 40 `IfcRailing` export-parameter values in the office's
railings' data objects, so the office's railings do carry IFC export
parameters, and `attach_ifc_export_overrides` already attaches them to
the railing as `m_ifc_predefined_type`; the only thing that kept the
value out of the export was that `IFCRAILING` was not in the enumerator
table, so `predefined_type_for` returned `None` and the mapping's own
`None` was written. The mechanism is proven on other classes: RE-419
reads 872 of 884 furniture equal to Revit's with none different, and
RE-190 78 of 78 waste terminals, 51 of 51 electric appliances, 40 of 40
fire-suppression terminals, 15 of 15 sanitary terminals and 1 of 1 air
terminal. revit-ifc's `IFCExportInfoPair` keeps a value that is an
enumerator of the entity and defaults the rest (RE-419, cited by class,
CLEANROOM.md source 5).

**What stays `$`.** A railing with no "IFC Predefined Type" of its own
or its type's, and one whose value is not an `IfcRailingTypeEnum`
enumerator. I did not add the `NOTDEFINED` default RE-419 gave
furniture: the only railing measured with `NOTDEFINED` is the office's
one `KAI-6`, and I cannot tell whether its type carries the value or
nothing, so a default would write `NOTDEFINED` where Revit writes
`HANDRAIL` on any file whose export parameters are not read (Revit 2023
and earlier, where `attach_ifc_export_overrides` does not run). On the
office that leaves at most that one railing unset; on the other 41
models the railings whose types carry no value stay unset too. A Revit
2027 save keeps none, through `predefined_type_left_out`.

## Changes

- `src/ifc/category_map.rs`: `IFCRAILING` joins
`PREDEFINED_TYPE_ENUMERATORS` with `HANDRAIL`, `GUARDRAIL`,
`BALUSTRADE`, `FENCE`, `USERDEFINED`, `NOTDEFINED`
(`IfcRailingTypeEnum`), and the table's doc comment records why the
value is the railing type's and not its host's.
- `changelog.d/fixed/1713-railing-predefined-type.md`: the user-visible
change.
- `docs/release-1.0-criteria.md`: the RE-427 sentence no longer reads
the railing row of #1713 as open.

No test is edited. `tests/railing_type.rs` finds the railing by the last
quoted attribute of its `IFCRAILING` line, which is the `Tag` before and
after this change, and the type object's `Tag` likewise.

## Measured

One Measure run scored this change together with the four others it was
drafted beside (run 43058225020, head `d17975d3`, base `aa5dc4c6`):
every model, with the BIM4LCA office and housing, the 23 Revit 2025
models, Autodesk's samples of every release, rac_advanced, BIMcollab and
the held-out pairs. All 39 shards and both same-project gates passed,
and the check run `same-project gates` on `d17975d3` reads pass. 20 of
126 exports change; each changed row carries the name of the value its
change writes, so the rows below are this change's alone. A second run
kept both sides' exports of the 25 sample saves of 2024 to 2027, which
no Revit export scores, and they were compared entity by entity with the
step ids taken out (run 43073245751). A third measured the four office
files with `--revit-set-placement`, as W7 is measured (run 43073951032).
After the second read's two fixes, the stack's final head with `main`
merged (`e41d96b5` against `39826420`) was measured again in full (run
43077331708, rows registered on #1636 before it was read): every row
below repeats, 24 of 126 exports move and no other, and both
same-project gates pass on that head.

| Model | `IfcRailing.PredefinedType` same as Revit, before | after |
differs | unset where Revit writes `NOTDEFINED` |
|---|---:|---:|---:|---:|
| Office as built | 0 of 41 | 40 of 41 | 0 | 1 |
| Office at permit | 0 of 41 | 40 of 41 | 0 | 1 |
| Timber office as built | 0 of 41 | 38 of 41 | 0 | 3 |
| Timber office at permit | 0 of 41 | 38 of 41 | 0 | 3 |
| Office terrain, concrete and timber | 0 of 1 each | 1 of 1 each | 0 |
0 |
| Housing terrain, concrete and timber | 0 of 2 each | 2 of 2 each | 0 |
0 |
| Concrete housing as built and at permit, on `main` with #1738 | 0 of
43 each | 43 of 43 each | 0 | 0 |
| Timber housing as built and at permit, on `main` with #1738 | 0 of 56
each | 56 of 56 each | 0 | 0 |

- No railing differs from Revit's on any model. The ones left are
railings whose type holds no value: Revit writes `NOTDEFINED` there and
rvt-rs writes nothing, as before.
- The four housing rows are from the final run: #1738, which landed
between the two runs, reads the housing's railing types from their
latest copy, and with it all 198 housing railings take Revit's value. On
the first run's base they were unchanged.
- No other model moves: the Revit 2025 models, the held-out pairs and
every sample save are unchanged by this change.
- `FENCE` is not listed: it is a railing type in IFC4X3 only, and the
first draft of this change listed it (found by the second read, fixed in
`d8944595`). A railing holding it keeps no `PredefinedType`.
- **Type objects, which no export scores.** rvt-rs writes an
`IfcRailingType` where Revit's exports of these models write none (the
census's "typed in ours but not in Revit's export", unchanged), and a
railing type now takes its value as the types of the other listed
classes do: on the office 4 `GUARDRAIL`, 2 `HANDRAIL` and 1 `NOTDEFINED`
where all 7 were `NOTDEFINED`. On the timber office one type whose
railings hold two different values is written as two type objects, by
the rule that already keys a type object by entity and predefined type,
so its type objects go from 1,432 to 1,433 as built and 1,399 to 1,400
at permit. No WHERE rule finding is added on any model.

## Still open

- The 1 and 3 railings Revit writes `NOTDEFINED` on are left unset.
Writing `NOTDEFINED` where a type holds no value would close them on
these files, but RE-427 found the 2027 exporter leaves the attribute
off, so it is not written without a measurement per release.

The four changes measured with this one are merged (#1761 to #1764).
`main` is merged into this branch, its diff is the railing change alone
(three files, checked equal to its own two commits), and that head is
measured again on its own: run 43089839851, rows registered on #1636
before it is read. First draft: #1729.

## Testing

- Built, linted and tested by CI on this head; nothing was built on a
workstation.
- Verified end to end on real Revit files against Revit's own exports:
the Measure runs named above, which anyone can repeat with `gh workflow
run measure.yml --ref main -f ref=<this head> -f
base=aa5dc4c6d93e861015c10e0a0d8f9f16c8b57e71 -f nordic=true -f
r2025=true -f samples=true -f racadv=true -f bimcollab=true -f
holdout=true`.
- No test was added: no unit test, and no pinned count moves except
where the body says so.

## Audit-honesty checklist

- [x] Docs state what this change writes and what it leaves out
- [x] A changelog fragment under `changelog.d/`
- [x] No emojis, private paths or personal data in committed files
- [x] Limits are in the body above and in the code's doc comments

## Legal and contribution hygiene

- [x] Apache-2.0
- [x] No Autodesk proprietary source, decompiled internals or NDA
material. Where revit-ifc (CLEANROOM.md source 5) is cited, it is read
and cited by file and class, and no code is copied.
- [x] No fixture with real-world personal data

## Breaking changes

None.
@DrunkOnJava
DrunkOnJava deleted the pilot/07-railing-predefined branch November 12, 2026 02:13
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant