…r its type's value (#1713)
Owner
Author
|
Superseded by #1765: the same commit on a fresh branch, with the measured rows in its body. |
7 tasks done
DrunkOnJava
added a commit
that referenced
this pull request
Nov 11, 2026
…1713) (#1765) ## Summary Revit's export gives every `IfcRailing` a `PredefinedType`; rvt-rs wrote `$` on all 378 railings of the 42 models with a Revit export (#1713). This adds `IFCRAILING` to `category_map::PREDEFINED_TYPE_ENUMERATORS` with the IFC4 `IfcRailingTypeEnum` enumerators, so a railing takes its own or its type's "IFC Predefined Type" where that value is an enumerator of the entity — the same rule RE-45 and RE-419 already apply to slabs, coverings, shading devices, roofs, the waste, electric, fire-suppression, sanitary and air terminals, and furniture. Nothing else changes: the `Railing` mapping keeps no default, and `category_map::predefined_type_left_out` still keeps the occurrence's value off a Revit 2027 save (#1692). ## Evidence **What Revit writes.** The office's own IFC4 export (`revit.ifc`) holds 41 `IFCRAILING`, and rvt-rs's export of the same file holds the same 41 by `Tag`, each with `$` in the last attribute. Tabulated by the type name (the text before the last colon of `Name`) and the last attribute: | type | railings | Revit's `PredefinedType` | |---|---:|---| | `KAI-4` | 10 | `HANDRAIL` | | `KJO-1` | 22 | `HANDRAIL` | | `KAI-1` | 1 | `GUARDRAIL` | | `KAI-2` | 2 | `GUARDRAIL` | | `KAI-3` | 2 | `GUARDRAIL` | | `KAI-5` | 3 | `GUARDRAIL` | | `KAI-6` | 1 | `NOTDEFINED` | 32 `HANDRAIL`, 8 `GUARDRAIL`, 1 `NOTDEFINED`, and every railing of a type has that type's value: 7 types, 7 values. **What does not decide it.** Not the name: `KAI-4` is `HANDRAIL` and `KAI-1` is `GUARDRAIL`, and `KAI-6` is `NOTDEFINED`. Not the host: RE-390 counts 26 of the office's railings naming a stair and 8 naming a ramp, where 32 are `HANDRAIL`, so a stair-hosted railing is not the rule and a ramp-hosted one is not either. **What does.** A value that is constant per railing type is the type's own, which is what RE-45's "IFC Predefined Type" reads (the instance's, else its type's, `ExportParameters::effective_predefined_type`). RE-190 measured 40 `IfcRailing` export-parameter values in the office's railings' data objects, so the office's railings do carry IFC export parameters, and `attach_ifc_export_overrides` already attaches them to the railing as `m_ifc_predefined_type`; the only thing that kept the value out of the export was that `IFCRAILING` was not in the enumerator table, so `predefined_type_for` returned `None` and the mapping's own `None` was written. The mechanism is proven on other classes: RE-419 reads 872 of 884 furniture equal to Revit's with none different, and RE-190 78 of 78 waste terminals, 51 of 51 electric appliances, 40 of 40 fire-suppression terminals, 15 of 15 sanitary terminals and 1 of 1 air terminal. revit-ifc's `IFCExportInfoPair` keeps a value that is an enumerator of the entity and defaults the rest (RE-419, cited by class, CLEANROOM.md source 5). **What stays `$`.** A railing with no "IFC Predefined Type" of its own or its type's, and one whose value is not an `IfcRailingTypeEnum` enumerator. I did not add the `NOTDEFINED` default RE-419 gave furniture: the only railing measured with `NOTDEFINED` is the office's one `KAI-6`, and I cannot tell whether its type carries the value or nothing, so a default would write `NOTDEFINED` where Revit writes `HANDRAIL` on any file whose export parameters are not read (Revit 2023 and earlier, where `attach_ifc_export_overrides` does not run). On the office that leaves at most that one railing unset; on the other 41 models the railings whose types carry no value stay unset too. A Revit 2027 save keeps none, through `predefined_type_left_out`. ## Changes - `src/ifc/category_map.rs`: `IFCRAILING` joins `PREDEFINED_TYPE_ENUMERATORS` with `HANDRAIL`, `GUARDRAIL`, `BALUSTRADE`, `FENCE`, `USERDEFINED`, `NOTDEFINED` (`IfcRailingTypeEnum`), and the table's doc comment records why the value is the railing type's and not its host's. - `changelog.d/fixed/1713-railing-predefined-type.md`: the user-visible change. - `docs/release-1.0-criteria.md`: the RE-427 sentence no longer reads the railing row of #1713 as open. No test is edited. `tests/railing_type.rs` finds the railing by the last quoted attribute of its `IFCRAILING` line, which is the `Tag` before and after this change, and the type object's `Tag` likewise. ## Measured One Measure run scored this change together with the four others it was drafted beside (run 43058225020, head `d17975d3`, base `aa5dc4c6`): every model, with the BIM4LCA office and housing, the 23 Revit 2025 models, Autodesk's samples of every release, rac_advanced, BIMcollab and the held-out pairs. All 39 shards and both same-project gates passed, and the check run `same-project gates` on `d17975d3` reads pass. 20 of 126 exports change; each changed row carries the name of the value its change writes, so the rows below are this change's alone. A second run kept both sides' exports of the 25 sample saves of 2024 to 2027, which no Revit export scores, and they were compared entity by entity with the step ids taken out (run 43073245751). A third measured the four office files with `--revit-set-placement`, as W7 is measured (run 43073951032). After the second read's two fixes, the stack's final head with `main` merged (`e41d96b5` against `39826420`) was measured again in full (run 43077331708, rows registered on #1636 before it was read): every row below repeats, 24 of 126 exports move and no other, and both same-project gates pass on that head. | Model | `IfcRailing.PredefinedType` same as Revit, before | after | differs | unset where Revit writes `NOTDEFINED` | |---|---:|---:|---:|---:| | Office as built | 0 of 41 | 40 of 41 | 0 | 1 | | Office at permit | 0 of 41 | 40 of 41 | 0 | 1 | | Timber office as built | 0 of 41 | 38 of 41 | 0 | 3 | | Timber office at permit | 0 of 41 | 38 of 41 | 0 | 3 | | Office terrain, concrete and timber | 0 of 1 each | 1 of 1 each | 0 | 0 | | Housing terrain, concrete and timber | 0 of 2 each | 2 of 2 each | 0 | 0 | | Concrete housing as built and at permit, on `main` with #1738 | 0 of 43 each | 43 of 43 each | 0 | 0 | | Timber housing as built and at permit, on `main` with #1738 | 0 of 56 each | 56 of 56 each | 0 | 0 | - No railing differs from Revit's on any model. The ones left are railings whose type holds no value: Revit writes `NOTDEFINED` there and rvt-rs writes nothing, as before. - The four housing rows are from the final run: #1738, which landed between the two runs, reads the housing's railing types from their latest copy, and with it all 198 housing railings take Revit's value. On the first run's base they were unchanged. - No other model moves: the Revit 2025 models, the held-out pairs and every sample save are unchanged by this change. - `FENCE` is not listed: it is a railing type in IFC4X3 only, and the first draft of this change listed it (found by the second read, fixed in `d8944595`). A railing holding it keeps no `PredefinedType`. - **Type objects, which no export scores.** rvt-rs writes an `IfcRailingType` where Revit's exports of these models write none (the census's "typed in ours but not in Revit's export", unchanged), and a railing type now takes its value as the types of the other listed classes do: on the office 4 `GUARDRAIL`, 2 `HANDRAIL` and 1 `NOTDEFINED` where all 7 were `NOTDEFINED`. On the timber office one type whose railings hold two different values is written as two type objects, by the rule that already keys a type object by entity and predefined type, so its type objects go from 1,432 to 1,433 as built and 1,399 to 1,400 at permit. No WHERE rule finding is added on any model. ## Still open - The 1 and 3 railings Revit writes `NOTDEFINED` on are left unset. Writing `NOTDEFINED` where a type holds no value would close them on these files, but RE-427 found the 2027 exporter leaves the attribute off, so it is not written without a measurement per release. The four changes measured with this one are merged (#1761 to #1764). `main` is merged into this branch, its diff is the railing change alone (three files, checked equal to its own two commits), and that head is measured again on its own: run 43089839851, rows registered on #1636 before it is read. First draft: #1729. ## Testing - Built, linted and tested by CI on this head; nothing was built on a workstation. - Verified end to end on real Revit files against Revit's own exports: the Measure runs named above, which anyone can repeat with `gh workflow run measure.yml --ref main -f ref=<this head> -f base=aa5dc4c6d93e861015c10e0a0d8f9f16c8b57e71 -f nordic=true -f r2025=true -f samples=true -f racadv=true -f bimcollab=true -f holdout=true`. - No test was added: no unit test, and no pinned count moves except where the body says so. ## Audit-honesty checklist - [x] Docs state what this change writes and what it leaves out - [x] A changelog fragment under `changelog.d/` - [x] No emojis, private paths or personal data in committed files - [x] Limits are in the body above and in the code's doc comments ## Legal and contribution hygiene - [x] Apache-2.0 - [x] No Autodesk proprietary source, decompiled internals or NDA material. Where revit-ifc (CLEANROOM.md source 5) is cited, it is read and cited by file and class, and no code is copied. - [x] No fixture with real-world personal data ## Breaking changes None.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
Revit's export gives every
IfcRailingaPredefinedType; rvt-rs wrote$on all 378 railings of the 42 models with a Revit export (#1713). This addsIFCRAILINGtocategory_map::PREDEFINED_TYPE_ENUMERATORSwith the IFC4IfcRailingTypeEnumenumerators, so a railing takes its own or its type's "IFC Predefined Type" where that value is an enumerator of the entity — the same rule RE-45 and RE-419 already apply to slabs, coverings, shading devices, roofs, the waste, electric, fire-suppression, sanitary and air terminals, and furniture. Nothing else changes: theRailingmapping keeps no default, andcategory_map::predefined_type_left_outstill keeps the occurrence's value off a Revit 2027 save (#1692).Evidence
What Revit writes. The office's own IFC4 export (
revit.ifc) holds 41IFCRAILING, and rvt-rs's export of the same file holds the same 41 byTag, each with$in the last attribute. Tabulated by the type name (the text before the last colon ofName) and the last attribute:PredefinedTypeKAI-4HANDRAILKJO-1HANDRAILKAI-1GUARDRAILKAI-2GUARDRAILKAI-3GUARDRAILKAI-5GUARDRAILKAI-6NOTDEFINED32
HANDRAIL, 8GUARDRAIL, 1NOTDEFINED, and every railing of a type has that type's value: 7 types, 7 values.What does not decide it. Not the name:
KAI-4isHANDRAILandKAI-1isGUARDRAIL, andKAI-6isNOTDEFINED. Not the host: RE-390 counts 26 of the office's railings naming a stair and 8 naming a ramp, where 32 areHANDRAIL, so a stair-hosted railing is not the rule and a ramp-hosted one is not either.What does. A value that is constant per railing type is the type's own, which is what RE-45's "IFC Predefined Type" reads (the instance's, else its type's,
ExportParameters::effective_predefined_type). RE-190 measured 40IfcRailingexport-parameter values in the office's railings' data objects, so the office's railings do carry IFC export parameters, andattach_ifc_export_overridesalready attaches them to the railing asm_ifc_predefined_type; the only thing that kept the value out of the export was thatIFCRAILINGwas not in the enumerator table, sopredefined_type_forreturnedNoneand the mapping's ownNonewas written. The mechanism is proven on other classes: RE-419 reads 872 of 884 furniture equal to Revit's with none different, and RE-190 78 of 78 waste terminals, 51 of 51 electric appliances, 40 of 40 fire-suppression terminals, 15 of 15 sanitary terminals and 1 of 1 air terminal. revit-ifc'sIFCExportInfoPairkeeps a value that is an enumerator of the entity and defaults the rest (RE-419, cited by class, CLEANROOM.md source 5).What stays
$. A railing with no "IFC Predefined Type" of its own or its type's, and one whose value is not anIfcRailingTypeEnumenumerator. I did not add theNOTDEFINEDdefault RE-419 gave furniture: the only railing measured withNOTDEFINEDis the office's oneKAI-6, and I cannot tell whether its type carries the value or nothing, so a default would writeNOTDEFINEDwhere Revit writesHANDRAILon any file whose export parameters are not read (Revit 2023 and earlier, whereattach_ifc_export_overridesdoes not run). On the office that leaves at most that one railing unset; on the other 41 models the railings whose types carry no value stay unset too. A Revit 2027 save keeps none, throughpredefined_type_left_out.Changes
src/ifc/category_map.rs:IFCRAILINGjoinsPREDEFINED_TYPE_ENUMERATORSwithHANDRAIL,GUARDRAIL,BALUSTRADE,FENCE,USERDEFINED,NOTDEFINED(IfcRailingTypeEnum), and the table's doc comment records why the value is the railing type's and not its host's.changelog.d/fixed/1713-railing-predefined-type.md: the user-visible change.docs/release-1.0-criteria.md: the RE-427 sentence no longer reads the railing row of PredefinedType: Revit's export writes one that rvt-rs leaves none or NOTDEFINED on, on walls, railings, ramps, roofs, proxies, light fixtures, pipe segments and stairs (42 models with a Revit export) #1713 as open.No test is edited.
tests/railing_type.rsfinds the railing by the last quoted attribute of itsIFCRAILINGline, which is theTagbefore and after this change, and the type object'sTaglikewise.What was not checked
.rvt, so I have not seen the office's railing types' "IFC Predefined Type" and cannot show that its value equals Revit's on any railing. The rule rests on the per-type correlation above and on the mechanism RE-45, RE-190 and RE-419 proved on other classes. The measurement must confirmdiffers0 andunset in rvt-rs0 on the office's 41 railings, and must say how many of the 378 railings of the 42 models still readunset(the ones whose types carry no value, and theNOTDEFINEDones).IfcRailingTypewhere Revit's export of the office writes none, so their newPredefinedTypehas no oracle;predefined_types_vs_ifc.pyscores a type class only where both files hold it.Pilot draft: written by an automated worker and pushed as proposed, with rustfmt applied. Not yet read by a maintainer session; please do not review, approve or arm it.