@puzzbobb the Measure run on this head is in (42521220132, One thing blocks it: the export is not valid IFC4 on four samples, and the body doesn't say so.
Two smaller points for the report:
Commit |
DrunkOnJava
force-pushed
the
survey-1190-s11
branch
from
November 9, 2026 07:55
c08f97f to
7b36e2e
Compare
12 of 15 tasks
DrunkOnJava
added a commit
that referenced
this pull request
Nov 9, 2026
…heir parts under them (#1190) (RE-366) (#1519) ## Summary Revit 2015 to 2023 curtain walls are now `IfcCurtainWall`, with their mullions and panels aggregated under them, turned along their own axes, and with `Span`, `Length` and `IsExternal`. It's a sixth slice of #1190, and the largest gap by element count: 4,661 parts on `rac_advanced` alone. It's measured against the same Autodesk samples saved by a later release, and, as counts, against Revit's own exports of `rac_advanced` 2015 to 2020 and of Vitoria's two models, all three IFC2X3; no Revit IFC4 export of a 2015 to 2023 curtain wall scores it. ## Motivation #1190 asks for each capability 2024 and 2025 have on every release from 2015 to 2027. The 2015 to 2023 branch of `recover_partition_schema_mvp` never called the curtain readers. `rac_advanced` on `main`: | | 2023 | 2024 | |---|---:|---:| | `IfcCurtainWall` | 0 | 34 | | elements aggregated under another | 0 | 4,515 | | `partition_family_instance_oriented_box` | 0 | 148 | | members with `Span` and `Length` | 0 | 3,252 | ## Changes - `src/research/partition_schema_mvp.rs`: the branch calls `attach_curtain_walls`, `attach_curtain_axes` and `attach_curtain_member_is_external` on `CURTAIN_32BIT_REVIT_VERSIONS` (2015 to 2023), and `bind_opening_hosts` after them, as on 2024. - `.../records_2023.rs`: `recover_2023_records` returns each record's reference list, and no longer binds hosts itself. 2008 to 2014 get the same binding as before. - `.../curtain.rs`: `attach_curtain_walls` takes those lists; `attach_curtain_axes` reads through `scan_transforms_in_layout`. - `src/research/partition_instance_transforms.rs`: `scan_transforms_in_layout`. `scan_instance_transforms`, which door and family readers call, is unchanged. - `.../parameters.rs`: a curtain wall takes `attach_record_is_external`. - `reports/element-framing/RE-366-2015-2023-curtain-walls.md`, an addendum to `docs/format-reconnaissance.md`, `docs/status.md`, `docs/evidence.md`, `docs/supported-profile.md`, `docs/release-1.0-criteria.md`, `changelog.d/added/1190-2015-2023-curtain-walls.md`. - `tools/re/curtain_classes_across_saves.py`: a curtain wall's class and its parts' wholes against the same project's 2024 save, by `Tag`, over a Measure run's kept exports. `docs/support-matrix.json`'s `element-record-curtain-walls` names 2015 to 2023 and RE-366, and the class counts the docs cite for Vitoria's `ALD26 Before` (1,305 to 1,310 of 1,314, 9 curtain walls written as walls to 4) are updated where they appear. ## Testing Unit tests are banned in this repository: do not add them. Show the change working end to end on real files instead. - [x] The required gate passes: `full / CI passed` on the rebased head (fmt, clippy, rustdoc, the test matrix with its `msrv` entry, the i686 job, corpus tier 2, IfcOpenShell, docs, wheels, audits, PII guard). - [ ] Verified end to end on real Revit files: the command, the files (and their licence), and the measured result against Revit's own export are in the PR body, with the script or probe that reproduces it - **Not against a Revit IFC4 export.** Measured against the same Autodesk samples saved by a later release, which can't catch an error that save shares, and, as counts, against three Revit exports that are IFC2X3: a disagreement with an IFC2X3 view is counted apart and removes nothing, and the agreements below are results against IFC2X3 too. The files are the pinned samples in `research/autodesk-sample-projects.tsv` (fetched, never stored). - Against Revit's own exports, [Measure run 42581222440](https://github.com/DrunkOnJava/rvt-rs/actions/runs/42581222440) (the rebased head `6f71f93a` against `main` at `58fd08f2`, 118 exports, held-out models as counts only): `rac_advanced` 2015 to 2020 (six pairs, the same counts on each) `IfcCurtainWall` 34 of 34 (0 before), `Pset_CurtainWallCommon.IsExternal` 32 of 32, `Pset_MemberCommon.Span` 3,241 equal, 11 different and 24 missing of 3,276 (0, 0 and 3,276 before), property values equal 2,503 to 5,776 of 16,108. The 11 different are the 3,241 of 3,252 below: about 7.5 mm off Revit's as the record boxes are, counted apart. Vitoria `ALD26 Before` (Revit 2018) `IfcCurtainWall` 5 of 9 (0 before), the other 4 stay `IfcWall`, since by RE-46's and RE-72's rules neither a mullion's list nor a curtain grid that a part names names them, `Span` 206 of 206, equal 2,737 to 2,948 of 5,317; the held-out `ALD26 Project` 5 of 8, `Span` 206 of 206, equal 3,291 to 3,502 of 6,140. No other export of the 118 moves except the 22 samples below. - Against the 2024 save, by `Tag`: | save | curtain walls | aggregated as 2024 | under another wall | not aggregated | |---|---:|---:|---:|---:| | `rac_advanced` 2015 to 2017 (each) | 34 of 34 | 4,384 | 0 | 80 | | `rac_advanced` 2018, 2019 (each) | 34 of 34 | 4,463 | 0 | 1 | | `rac_advanced` 2020 | 34 of 34 | 4,454 | 0 | 10 | | `rac_advanced` 2021 | 34 of 34 | 4,444 | 0 | 71 | | `rac_advanced` 2022 | 34 of 34 | 4,463 | 0 | 52 | | `rac_advanced` 2023 | 34 of 34 | 4,454 | 0 | 61 | | `rac_basic` 2015, 2016, 2019, 2022, 2023 (each) | 9 of 9 | 188 | 0 | 4 | - Those not aggregated, on `rac_advanced` 2023: 45 mullions at a corner whose record names two curtain walls, which the rule declines; 15 stair flights and landings, which this doesn't read; 1 opening. - Bodies, to 3 mm on the world box and 0.1% on the volume (`tools/re/save_pair_bodies.py` for the oriented boxes), `main` against this change: `rac_advanced` 2023 members 3,206 to 3,312 of 3,312, panels 1,307 to 1,349 of 1,349; 2015 and 2019 members 2,779 to 2,885 of 3,276, panels 1,145 to 1,187 of 1,349; `rac_basic` 2023 188 of 188 before and after. The 148 oriented boxes are the 2024 save's on 2015, 2019, 2021 and 2023. On `rac_advanced` 2019 no body that matched on `main` stops matching, and the 553 that still differ have the box they have on `main`, at worst 15 mm off. RE-180 records `rac_advanced` 2019 and 2020 as an earlier edit in which curtain walls moved. - Values against the 2024 save, `rac_advanced` 2023 / 2015: `Span` and `Length` 3,252 of 3,252 / 3,241 of 3,252, the 11 about 7.5 mm off as their boxes are; member `IsExternal` 3,147 equal and 45 not read / 3,077 and 79; panel `IsExternal` 1,307 of 1,307 on both; curtain wall `IsExternal` 34 of 34 on both. - Class and parts over every save (`tools/re/curtain_classes_across_saves.py` on the kept exports of Measure run 42579926185, head `6f71f93a`): of the 31 saves of 2015 to 2023 that have a 2024 save of the project, 511 walls are `IfcCurtainWall` here and in the 2024 save; none is `IfcWall` there, and none that is `IfcCurtainWall` there is `IfcWall` here. No mullion or plate sits under a wall that is not a curtain wall, here or in the 2024 save (49,903 sit under a curtain wall here). The 511 are 34 on each of 9 `rac_advanced` saves, 9 on each of 9 `rac_basic` saves and 31 on each of 4 `rme_*` saves, which is why the tables above, covering the first two, hold 387. - Across 33 saves of 2015 to 2023 against `main`: 266 doors no longer fill an opening in a curtain wall and 235 curtain walls lose that void, all of them now equal to the 2024 save. 225 members and panels change storey, all to the 2024 save's. 511 elements go from `IfcWall` to `IfcCurtainWall`, gaining `Pset_CurtainWallCommon.IsExternal` and losing `Pset_WallCommon.IsExternal` and `ExtendToStructure`. 4 curtain walls on `rac_basic` gain a family name. No element appears or goes, and no GlobalId changes. - Byte identity, Measure run 42581222440: of 118 exports, 88 are byte for byte `main`'s. The 30 that differ are the 22 samples that hold curtain walls (`rac_advanced` and `rac_basic` of 2015 to 2023, `rme_advanced` and `rme_basic` of 2015 and 2019), the six `racadv` pairs and the two Vitoria models. No export of 2024 or later, and none of the office, the Revit 2025 models, Core Interior, RE1 or BIMcollab moves, and no other held-out model. The same-project gates pass. - [x] If this touches the IFC exporter: the witness verdicts replay (see CONTRIBUTING.md) or the changed observations are refreshed in this PR - Core Interior (2024) exports byte for byte as before, so its observations are unchanged. - [ ] If this is a performance change: reran `tools/bench.sh` and attached the before / after - N/A. No difference above the noise of three runs each (`rac_advanced` 2023, about 4.3 s; `rac_basic` 2019, about 2 s). ``` tools/fetch-autodesk-samples.sh samples 2015 2024 for f in samples/*.rvt; do rvt-ifc "$f" -o "${f%.rvt}.ifc"; done python3 tools/re/save_pair_bodies.py samples/2023-racadvancedsampleproject.ifc samples/2024-racadvancedsampleproject.ifc --sources partition_family_instance_oriented_box ``` ## Audit-honesty checklist - [x] README / docs reflect the current state after this PR — no claims of features that are not actually shipped in this PR - [x] A user-visible change has its entry as a fragment under `changelog.d/<section>/` (see `changelog.d/README.md`), not in `CHANGELOG.md` - [x] If a limitation was resolved, the "Known limitations" / "What works today" section in the relevant docs is updated - `docs/status.md`, `docs/evidence.md`, `docs/supported-profile.md`, `docs/release-1.0-criteria.md`. The 2008 to 2014 rows now say "as on 2015, without curtain walls". - [x] If a new limitation was introduced, it is documented in the PR body and in-code - None new. Still not read, RE-366 §5: a curtain wall's `Length`; family and type names on mullions and panels, so their `ObjectType`, `Reference` and materials; a part's `NetVolume` and `NetSurfaceArea`; a corner mullion's curtain wall; a curtain grid's. - [x] Commit messages describe WHAT changed and WHY, not "fix things" or "updates" - [x] No emojis in code, docs, or commit messages - [x] No private paths, personal email addresses, or internal jargon in committed files - [ ] If this is a reverse-engineering finding: a reproducible probe under `probes/examples/` and a dated addendum to `docs/format-reconnaissance.md` are included - The addendum is included. No new byte layout is decoded, so there is no probe. ## Legal and contribution hygiene - [x] I agree this work is licensable under Apache-2.0 (see `CONTRIBUTING.md`) - [x] This PR contains no Autodesk proprietary source, decompiled internals, or NDA'd SDK content (see `CLEANROOM.md`) - [x] Any new test fixtures use synthetic values (`testuser`, `111111`, `FY-20XX`, etc.) and contain no real-world PII - No fixtures. ## Breaking changes None. New public constants and a function; existing names and types are unchanged. ## Screenshots or output samples `rac_advanced` 2023 against its 2024 save, this branch: ``` tools/re/save_pair_bodies.py --sources partition_family_instance_oriented_box same 148, differ 0, not in the reference 0 ``` ## Related issues Refs #1190, #1158 ## Notes It edits the same rows of `docs/supported-profile.md`, `docs/evidence.md` and `docs/status.md` as #1518, #1520 and #1524, so whichever merges later takes a small conflict. --------- Co-authored-by: Griffin Long <[email protected]>
3 tasks done
…own record on Revit 2015 to 2027, and ports their SystemType (DrunkOnJava#1190) (RE-371) On Revit 2015 to 2023, 2026 and 2027 a duct was written untyped, named Duct-<ElementId>, its record box as its body, with no Length and two unplaced ports: 724 ducts on rme_basic and 728 on rme_advanced. On 2024 and 2025 RE-134 typed ducts by a byte scan that found no type for any of Snowdon Towers HVAC's 1,053, and a duct off the model's axes had no Length or ends (356 of them). A duct tapped into another had no port or join there (406 on Snowdon), no port had a SystemType (DrunkOnJava#834), every Exhaust Air port had a direction where Revit's export writes SOURCEANDSINK, and on 2015 to 2022 no family instance's port or join was read. A duct's own RbsDuctCurve record holds all of it on every release from 2015 to 2027, in the shape of a pipe's (RE-370): its type (an AbsDuctType, named by its SymbolInfo and shaped by its sweep profile), its section and the direction its height lies along (m_vNormal), its one GLine at any slope, its reference level and the elevations of its ends above it, which Connector is at each end and where each tap is along the line, each connector's joins, and each connector's calculated direction and system classification (SegmentConnectorCalculation.m_eSystemType, numbered as a system type's m_basicSystemType). attach_native_ducts reads them in one projected pass, before RE-134's scan on 2024 and 2025, and writes the fields RE-134 writes plus the normal, the taps, the joins and, for a duct justified at its centre, its level and offsets. The line is held to a box test like RE-131's: the section swept along it must be the record box. The export draws the section along the line, writes each tap's port on the line, and adds Revit's Constraints elevations, Slope and justification. The connector pass reads each connector's system, writes the port's SystemType as revit-ifc names the classification (Supply and Return Air VENTILATION, Exhaust Air EXHAUST, Supply Hydronic HEATING; no other is measured), and writes every Exhaust Air connector SOURCEANDSINK. It and the family instances' joins now read 2015 to 2027 and a record's ids in their 4-byte form as well as their 8-byte one. A port joined to a placed one is at its point with its axis turned unless exactly one of the two is a sink, and a tap places no other port. A port whose own direction or system is not read (a family instance whose 2015 to 2022 record the native path does not decode) takes the opposite direction and the system of the port joined to it. Against Revit's own export of Snowdon Towers HVAC (2025) the record gives Revit's type name, Length, section, body and every Constraints value on 1,053 of 1,053 ducts, and the export now writes 5,155 of Revit's 5,217 ports (the other 62 are on flex ducts, not read) and 2,528 of its 2,590 connections, every port at Revit's point, SystemType Revit's on 5,118 (the other 37 electrical), FlowDirection on 4,889 (3,496 before). RE1 Mechanical's 25 ducts have Revit's type, length and body, and every port of RE1 Mechanical and Plumbing now has Revit's point and axis. On Autodesk's twelve MEP sample saves of 2015 to 2027 every duct is typed and drawn as the 2024 save's but nine the project replaced or redrew before 2015, and on 2025 to 2027 every port and connection is the 2024 save's. Nothing but ducts, ports and connections changes in the export. (cherry picked from commit c08f97f029b90179a13bbf78eecccfa4a402bc8f)
…ps the other, and the ones left out are counted (DrunkOnJava#1524) (RE-371) A connector has one physical partner. On the rme_advanced and rme_basic samples of Revit 2015 and 2019, five chains of three joins each hold one that the 2024 save does not have (a connector joined to the second connector of an element it is already joined to at its first), and the export was not valid IFC4: 10 ConnectedFrom and ConnectedTo findings on each file. A connector named with two partners now keeps the one both sides' lists name where exactly one is, and none otherwise; a join is written only where each end keeps the other, and the rest are counted in exported.port_joins_left_out. A duct's reference level pushed by its own record is not pushed again by attach_levels_32, and apply_partner_directions' comment says what the code does.
…es under the join rule (DrunkOnJava#1524) The ports table and the per-file table gave the totals before a join of two connectors was written only where each end keeps the other. Run 42585486357's exports of the four rme saves of 2015 and 2019, through the same comparison that reproduces the old rows to the digit, give 2,764 (2,764) and 2,859 (2,853) for rme_basic, 2,742 (2,742) and 2,819 (2,798) for rme_advanced; the 10 joins left out on each, and what they cost (5 ports' place and 5 ports' direction), are in section 5.
DrunkOnJava
force-pushed
the
survey-1190-s11
branch
from
November 9, 2026 09:22
a3c22a0 to
215fd38
Compare
DrunkOnJava
added a commit
that referenced
this pull request
Nov 9, 2026
…s an enumerated or list value (#1524) (#1590) ## Summary `tools/re/bodies_across_saves.py` skips a property that holds no single value instead of raising on it, so the same-project gate can judge an export in which a product carries an enumerated or list property. ## Motivation Measure run [42585494298](https://github.com/DrunkOnJava/rvt-rs/actions/runs/42585494298) on #1524 failed `Same-project gates` for the six `rme_advanced` and `rme_basic` saves of 2025, 2026 and 2027. Each one's `bodies_across_saves.txt` holds a traceback in place of its result: `AttributeError: entity instance of type 'IFC4.IfcPropertyEnumeratedValue' has no attribute 'NominalValue'`, from `properties`. The other nine samples (`rac_advanced`, `rac_basic`, `rst_basic`, each of 2025 to 2027) passed. #1524 types the 724 and 728 ducts of those samples, and a typed duct carries `Pset_DuctSegmentTypeCommon.Shape`, which the writer emits as an `IfcPropertyEnumeratedValue` (#686). `properties` read `prop.NominalValue` on every property of every product it compares, and an enumerated or list value has none. No export the check had read held one before: the same six saves passed in run [42583038481](https://github.com/DrunkOnJava/rvt-rs/actions/runs/42583038481) on #1587's head, whose exports type no duct there. ## Changes - `tools/re/bodies_across_saves.py`: `properties` reads `NominalValue` with `getattr(prop, "NominalValue", None)` and skips a property without one, as it already skipped one whose `NominalValue` is `None`. `placement_source` reads it the same way (it tested the property's name first, so it was not reached for a Shape, but it had the same pattern). ## Testing Unit tests: N/A. The check is the scorer run on the exports that tripped it. - **The six exports that failed**, from the `keep_ifc` run [42585486357](https://github.com/DrunkOnJava/rvt-rs/actions/runs/42585486357) of #1524's head, through this branch's scorer with each save held to the 2024 and 2025 saves as Measure holds it: all six print `bodies across saves: PASS` and exit 0, with their ports, cut openings, door and window sizes, properties and census lines compared against the 2025 save (for example `rme_advanced` 2026: ports 7,276 of 7,276 the same, properties 5,158 equal and none different, census 6,605 bodies the same). The same scorer from `main` raises the `AttributeError` on all six, as the run's own files show. - **The Measure with this branch as its scorers' ref** is dispatched on #1524's head next; its `same-project gates` verdict is the check on that pull request. ## Audit-honesty checklist - [x] The gate still fails on a real difference: only the read of a property without a single value changed; every comparison after it is as before. - [x] No emojis, private paths or PII. ## Legal and contribution hygiene - [x] Apache-2.0. No Autodesk source, internals or NDA material. ## Breaking changes None.
Owner
|
Thanks for the ducts. What changed on this branch since you pushed:
rvtDevelop reads it next and I land it after. |
3 tasks done
DrunkOnJava
added a commit
that referenced
this pull request
Nov 9, 2026
## Summary Release 0.17.0. Everything merged since 0.16.1 (29 pull requests, `main` at 52282ea): Revit 2015 to 2023 curtain walls, curtain parts and steel beam I sections, duct and port reads of Revit 2015 to 2027, walls' `Height` on 2015 to 2023, room outlines from a stored solid's edges, two wall rules on Revit 2024 (a stub cut whole; a profile-edited wall's top and `Height`), no `ObjectType` on Revit 2026 and 2027 saves, and two export claims made conditional (#1598). The saved-mesh default for every class (#1610) and the wall profile pockets (#1608) are not in it; they go in the next release. ## Changes - Version 0.16.1 -> 0.17.0 in: - Cargo.toml; - rvt-py/Cargo.toml and its `=` pin; - rvt-mcp/Cargo.toml and its `=` pin; - rvt-wasm/Cargo.toml; - tools/stream_evidence/Cargo.toml's pin; - viewer/package.json; - CITATION.cff (version and date); - Cargo.lock and fuzz/Cargo.lock. - `python3 tools/release/changelog.py assemble`: 17 fragments go into `[0.17.0]`, with an introduction, what is not measured, and "Upgrading from 0.16". - README: the latest release and the "Upgrading from 0.16" and "after 0.17.0" fragments sentence. - The Core Interior witness observations and verdicts, and the synthetic fixtures, from this pull request's CI run (to be pushed). ## Testing - `python3 tools/ci/release_preflight.py check --event workflow_dispatch --ref-type branch --ref-name release/v0.17.0 --sha HEAD`: ok, version 0.17.0. - `python3 tools/release/changelog.py check`: ok. - The release's baseline Measure, `main` at 52282ea against v0.16.1 with every flag and the held-out models: run [42632958286](https://github.com/DrunkOnJava/rvt-rs/actions/runs/42632958286) (its result goes into the changelog before this is merged). - The dry run RELEASE.md step 7 asks for, `publish.yml` dispatched on this branch (to be run, and linked here). Unit tests: N/A. ## Audit-honesty checklist - [x] Each entry keeps its caveats; the introduction lists what is not measured. - [x] No emojis, private paths or PII. ## Legal and contribution hygiene - [x] Apache-2.0. No Autodesk source, internals or NDA material. ## Breaking changes The API changes of #1524 and #1598 and the `ObjectType` change of #1601, listed under "Upgrading from 0.16".
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
A duct's own native record (
RbsDuctCurve) gives it its type, its section, the line it runs along at any slope, its taps, its reference level and elevations, and each connector's join, direction and system, on every release from 2015 to 2027. Every duct is now typed and drawn as its section along that line, with Revit'sConstraintsvalues; every port gets theSystemTypeits connector's system names, and Exhaust Air ports areSOURCEANDSINK; on 2015 to 2022 the family instances' ports and joins are read. On Snowdon Towers HVAC (2025) the record gives Revit's own type name,Length, section, body andConstraintsvalues on 1,053 of 1,053 ducts. It's an eleventh slice of #1190, stacked on #1523 (pipes, RE-370), whoseattach_native_pipesit mirrors.Motivation
Duct-<ElementId>box with noLengthand two unplaced ports: 724 ducts onrme_basic, 728 onrme_advanced.Lengthor ends.SystemType(A port's SystemType (its connector's system classification) and an electrical port's Flow=Source/Sink description are not written (RE-212 follow-up) #834); Revit's IFC4 export writes one on every port.SOURCEANDSINK(1,004 on Snowdon).rme_basic, against 7,370 and 2,948 on its 2024 save.Changes
src/research/partition_schema_mvp/mep.rs:attach_native_ducts. One projected native pass over the ducts not yet drawn along their line and the file'sAbsDuctTyperecords. From each duct's record: its type (m_idType, named bySymbolInfo.m_name, shaped by its sweep profile), its section (m_dWidthOrDiameter,m_dHeight, the height alongm_vNormal), its oneGLine, its taps (SegmentConnectorPosition.m_paramOnCurvebetween 0 and 1), each connector's join (m_arrRefs, type 1), and, where it's justified at its centre, its reference level (m_assocLevelId, before 2024m_idLevelStart) and the elevations of its ends above it (m_dOffsetStart,m_dOffsetEnd). It writes the fields RE-134 writes, so the system family,Pset_DuctSegmentTypeCommon, quantities and end ports come from the existing code, plus the normal, the taps, the joins and the offsets. The line must pass a box test like RE-131's (the swept section is the record box within 0.002 ft); an oval duct keeps its box. It runs in the 2015 to 2023 branch and, on 2024 to 2027, before RE-134's scan; RE-134, the duct end keys and RE-172's level leave a duct the record gave values alone.native_pipe's line and end reading is shared, and a pipe's record now gives its joins too. The 2015 to 2023 branch callsattach_connector_pairs.src/research/native_connectors.rs: the connector pass reads each calculation'sm_eSystemType(Calculation,InstancePort::system_type), names it (distribution_system_of: 1 and 2VENTILATION, 3EXHAUST, 7HEATING, the classifications measured against Revit's IFC4 export; revit-ifc'sConnectorExporterread for the names, nothing copied), and gives an Exhaust Air connectorSOURCEANDSINK(port_flow_direction). It andfamily_instance_joinsread 2015 to 2027 and ids in their 4-byte form as well.native_duct_shapesreads 2015 to 2027.src/ifc/export_content.rs: a duct drawn along its line is its section extruded along it (BodySourcenative_duct_line); each tap's port is on the line at its parameter;Constraintsgets the Start, End and Middle Elevation, the Lower and Upper End Centerline, Bottom and Top Elevation,Slope(anIfcRatioMeasure) and the justification.src/ifc/mod.rs,src/ifc/step_writer.rs,src/ifc/entities.rs: a port'sSystemTypeis written; a port joined to a placed one takes its point with the axis turned unless exactly one of the two is a sink; a tap places no other port; a port with no direction or system read takes the opposite direction and the system of the port joined to it.PropertyValue::Ratio.src/ifc/export_content.rs,src/ifc/mod.rs,src/ifc/from_decoded.rs,docs/export-diagnostics.mdand its schema: a join of two connectors is written only where each end keeps the other as its one partner, or as the one partner both sides' lists name; the joins left out are counted inexported.port_joins_left_outunderconnector_named_with_conflicting_partners.src/research/partition_schema_mvp/levels.rs: a reference level a duct's own record named is not pushed a second time.probes/examples/probe_re371_ducts.rs(each duct as the export draws it; with--native, each duct's record and every connector's calculation),tools/re/ducts_vs_ifc.py,reports/element-framing/RE-371-native-ducts.md, an addendum todocs/format-reconnaissance.md,docs/status.md,docs/evidence.md,docs/supported-profile.md,changelog.d/added/1190-ducts-slopes-port-systems.md.Testing
Unit tests are banned in this repository: do not add them. Show the change working end to end on real files instead.
tools/check-local.shpasses (fmt, clippy, rustdoc, build, real-file / CLI / contract checks)tools/check-local.sh --corpuson the local corpus passes: all 301 real-file tests on the default and full-corpus runs, and the API doc-id check. A first run failed one test,value_sources_offsets::project_corpus_value_sources_name_the_copy_the_reader_took, because the newBodySourcenative_duct_linenamed no reader; the duct's own record and its type's are now noted as its value sources (native_duct,native_duct_type, listed indocs/export-diagnostics.md), and the export doesn't change with it.cargo +1.87 check --all-targets(MSRV) is clean.probe_re371_ducts --nativeandtools/re/ducts_vs_ifc.py: Snowdon Towers HVAC (2025, Revit 2025's IFC4X3 export, local only) 1,053 of 1,053 ducts with Revit's type name,Length, section and body (the swept section's world box against Revit's within 0.01 ft; 1,045 round, 8 rectangular, level, vertical and sloped), and everyConstraintsvalue Revit writes (Slopeon 1,012 of 1,012, none on the 41 vertical ducts, as Revit); RE1 Mechanical (MIT,magnetar-io/revit-test-datasets, IFC2X3) 25 of 25 with Revit's type name,Lengthand body.tools/re/ports_vs_ifc.pyon the export: Snowdon Towers HVAC 5,155 ports (4,749 before; Revit 5,217, the other 62 on its 31 flex ducts, not read), 2,528 of Revit's 2,590 connections (2,122 before) and none it leaves out, every port at Revit's point (17 unplaced before), 5,008 with its axis (4,100),SystemTypeRevit's on 5,118 (0; the other 37 electrical),FlowDirectionon 4,889 (3,496), all 1,004 Exhaust Air ports among them. RE1 Mechanical and Plumbing keep 59 of 59 and 118 of 118 connections and every flow, and every port of both now has Revit's point and axis (16 fitting ports were reversed). The BIM4LCA office's 24 pipe ports areHEATING, as Revit's (local only).rme_basicandrme_advancedname one duct connector as the partner of two others: three joins in a chain, of which the 2024 save has two and not the third. The first form of this change wrote all three (2,774 connections onrme_basic2019, 2,769 of them the 2024 save's). A join is now written only where each of its ends keeps the other, so 10 joins on each of those four saves are left out, five the 2024 save has and five it does not, and each is counted. Of the 93 models of Measure run 42585494298 those four are the only ones with a join left out. Onrme_basic2019 the connections are 2,764 and all the 2024 save's, and the cost is 10 ports: 5 lose the place their join gave them and 5 their direction (flow different 38 to 43). The ports table and the per-file table of RE-371 are restated, with the comparison that reproduces the old rows to the digit (section 5).SOURCE_DATE_EPOCH=1700000000: 25 of 58 sample saves (Autodesk's 53 of 2015 to 2027, Snowdon Towers' five of 2024) and 173 of 206 local project files of 2008 to 2027 export IFC and diagnostics byte for byte as before, Core Interior among them. On each of the 33 + 33 that change, an element-by-element comparison (class, name, every property set and representation by GlobalId; every port's name, flow, type, system and place; the connections) finds nothing changed but ducts, ports and connections. The files that change are the MEP files, the 2025 Snowdon, Golden Nugget and サンプル files, RE1 Mechanical and Plumbing (port axes), the office (24 ports'SystemType), and architectural files of 2015 to 2023 whose MEP family instances (lighting, sanitary, electrical fixtures, 30 to 36 a file) now have ports. Report §6 has the table. The join rule changes the four saves above further, and no other model of that run.tools/bench.shand attached the before / afterrme_basic2027, 30.2 s and 28.1 s on Golden Nugget's building services, 3.9 s on both forrac_advanced2023. A 2015 to 2022 MEP file now reads its family instances' ports and joins, as 2024 does:rme_basic2019 takes 6.7 s against 4.4 s (its 2024 save takes 17.4 s).Audit-honesty checklist
changelog.d/<section>/(seechangelog.d/README.md), not inCHANGELOG.mddocs/status.md,docs/evidence.md(the 2024 and 2025, 2026 and 2023 rows),docs/supported-profile.md.GHermiteSpline), oval ducts' sweep, a pipe'sConstraintselevations and a level pipe's invert outside 2025 (no oracle), a port'sSystemTypeother than the four measured and any electrical port's, the flow directions revit-ifc's export order decides (266 on Snowdon), and the 2015 to 2022 family instances the native path doesn't decode.probes/examples/and a dated addendum todocs/format-reconnaissance.mdare includedprobes/examples/probe_re371_ducts.rs,tools/re/ducts_vs_ifc.py.Legal and contribution hygiene
CONTRIBUTING.md)CLEANROOM.md)ConnectorExporter(CLEANROOM.md source 5) was read for how Revit's export names a classification and orders a join's ports; no code was copied or translated.testuser,111111,FY-20XX, etc.) and contain no real-world PIIBreaking changes
Public API, research and IFC model types:
native_connectors::port_flow_directiontakes a fourth argument, the connector's system classification.native_connectors::ConnectorPorts::segmentsmaps to aCalculation(direction and system) instead of a direction.native_connectors::InstancePorthas asystem_typefield, andifc::entities::IfcEntity::Portasystem_typefield (#[serde(default)], so serialised models still read).ifc::entities::PropertyValuehas aRatiovariant; an exhaustivematchoutside the crate needs an arm for it.ifc::IfcModelandifc::ExportedModelDiagnosticshave aport_joins_left_outfield (a count by reason); a struct literal of either outside the crate needs it.New:
NATIVE_DUCT_REVIT_VERSIONS,DUCT_NORMAL_FIELDS,DUCT_OFFSET_FIELDS,DUCT_TAPS_FIELD,DuctBody,duct_body_from_fields,duct_offsets_from_fields,duct_taps_from_fields,square_to,native_connectors::{Calculation, EXHAUST_AIR, distribution_system_of},DuctShape::of_profilemade public.Screenshots or output samples
rme_basic, duct 420841, as the export writes it:Related issues
Refs #1190, #96, #834, #869
Notes
Rebased on
mainafter RE-370 and after #1518, #1519 and #1587 landed. rvtReview's commits on this branch are the join rule (baab0262) and the restated RE-371 (215fd384).