Skip to content

feat(ifc): a wall whose base join names an element covering its plan in part is cut over the covered part (#1411) (RE-349) - #1469

Closed
DrunkOnJava wants to merge 3 commits into
mainfrom
fix/1411-base-covered-in-part
Closed

DrunkOnJava wants to merge 3 commits into
mainfrom
fix/1411-base-covered-in-part

Conversation

@DrunkOnJava

@DrunkOnJava DrunkOnJava commented Nov 5, 2026 •

Copy link
Copy Markdown
Owner

Summary

A wall whose base join names a floor or footing that covers only part of the wall's plan is cut at that element's top over the covered part and stands from its own base over the rest, as Revit draws it. Draft until the unfiltered run and the second read.

Motivation

#1411: the BIM4LCA office's Basement walls 2058499 and 2058501 as built stand past the edge of their footing (2058504), which covers their plan only in part. RE-337 (#1398) kept their ends 0.31 ft short of Revit's because a base that is not cut would have grown their volume from 4.497 to 6.919 ft3 over Revit's.

Changes

  • src/ifc/export_content/wall_tops.rs: decide_base takes an element that covers the plan in part (covered_pieces: the wall's convex pieces clipped by the element's outline), base_cut_solid splits each piece into the part inside the covered pieces, cut at the element's top, and the rest from the wall's own base.
  • New BodyBaseSource values wall_base_cut_at_floor_covering_in_part and wall_base_sloped_at_floor_covering_in_part; new BaseCoverRefusal reason partly_covered_plan_not_read (docs and schema updated).
  • tests/export_decisions_counts.rs: the office as built no longer witnesses wall_base_cut_refused and wall_end_extension_refused, so the table no longer requires them.
  • Report reports/element-framing/RE-349-wall-base-covered-in-part.md, a docs/format-reconnaissance.md addendum, a changelog fragment and the support-matrix evidence line.

Testing

Unit tests are banned; measured end to end on Revit's own exports.

  • Verified end to end on real Revit files: Measure run 42099826920 (both BIM4LCA office files, CC BY-SA 4.0, scorers wall_heights_vs_ifc, wall_quantities_vs_ifc, wall_top_cover_vs_ifc, wall_layers_vs_ifc) at c413f382 against main at 44c055db. Reproduce: gh workflow run measure.yml --ref main -f ref=c413f382e7615100170862e14bb50c7e431b582e -f base=main -f nordic=true -f models="nordic-office-as-built nordic-office-permit" -f scorers="wall_heights_vs_ifc wall_top_cover_vs_ifc wall_quantities_vs_ifc wall_layers_vs_ifc" -f keep_ifc=true.
  • Office as built: of 607 walls, 2 bodies differ (2058499, 2058501). Both keep Revit's lowest point (174.2126 ft), take Revit's end (y 75.7285 to 75.4183 ft) and go from 4.497 ft3 over Revit's volume (35.302 against 30.805) to 0.147 ft3 under (30.658), the upper step of the end that RE-337 omits (Wall ends Revit steps up the height: the second step is left out (RE-337 follow-up) #1410). The office at building permit is byte for byte main's.
  • Not yet measured on this head: Core Interior, RE1 Architecture, the R2025 models, Autodesk's samples, the held-out files (the unfiltered run, which also writes the same-project verdict, comes before this is armed). The level top of a partial cover is exercised by no measured wall.

Audit-honesty checklist

  • README / docs reflect the current state after this PR
  • A user-visible change has its entry as a fragment under changelog.d/fixed/
  • No emojis, no private paths
  • Reverse-engineering finding: report RE-349, addendum in docs/format-reconnaissance.md; the measurement is reproducible from the office exports with the scorers above

Legal and contribution hygiene

  • Apache-2.0; no Autodesk proprietary source (clean-room: Revit's exported IFC bodies and public bytes only)

Breaking changes

None. New property values and one new refusal reason; wall_base_refusals and wall_end_refusals of the office as built are empty instead of 2 each.

Related issues

Closes #1411

Closed unmerged 2026-11-05: replaced by #1470, which holds these commits and the second read's fixes. Landed alone, this PR would have put the labelled approximation wall_end_to_base_wall_upper_step_omitted on two more walls until #1470 retired it, and Griffin approved it for one wall case only.

@DrunkOnJava DrunkOnJava added the ready-when-green Draft whose code is complete: marked ready for review once its fast CI passes label Nov 5, 2026
@DrunkOnJava
DrunkOnJava marked this pull request as ready for review November 5, 2026 20:21
@DrunkOnJava DrunkOnJava removed the ready-when-green Draft whose code is complete: marked ready for review once its fast CI passes label Nov 5, 2026
@DrunkOnJava DrunkOnJava closed this Nov 5, 2026
DrunkOnJava added a commit that referenced this pull request Nov 5, 2026
…and a profile-edited wall's end follows the walls its record joins (#1409, #1410, #1411) (RE-348) (RE-349) (#1470)

## Summary

Two readers for one set of walls, in one PR (it holds #1469's commits;
#1469 is closed unmerged):

- RE-349 (#1411): a wall whose base join names a floor or footing that
covers only part of its plan is cut at that element's top over the
covered part and stands from its own base over the rest.
- RE-348 (#1409, #1410): a profile-edited wall's end is drawn, at each
height, to the face of the first wall its record joins there
(`JoinEndGStep.m_realJoined`, in the record's order) that stands at that
height, instead of to the wall beneath up to that wall's top. The
labelled approximation of #1398
(`wall_end_to_base_wall_upper_step_omitted`) is retired.

**What changes in the diagnostics.** Every export's `diagnostics.json`
gains three counters, `exported.wall_end_sources`,
`exported.wall_base_sources` and `exported.wall_ends_order_dependent`
(zero or empty on all but the BIM4LCA office files). On the office as
built, `wall_base_refusals` `no_element_covers_the_wall_plan` (2) and
`wall_end_refusals` `base_not_cut_over_the_extended_plan` (2) go away,
`wall_base_sources` is 4 level cuts, 10 sloped and 2 `_in_part`,
`wall_end_sources` is 4 and `wall_ends_order_dependent` 4; at permit
`wall_end_refusals` `wall_beneath_not_one_rectangle` (2) becomes
`joined_wall_face_inside_the_wall` (2) and `wall_end_sources` is 4. The
first unfiltered run (`e5ff94f4`) marked every refusal and put two on
Autodesk's Snowdon Towers Architectural
(`joined_walls_do_not_reach_the_wall_height`: 736143, which `main`
already draws as Revit's export does, and 1996083, which it draws 1.03
ft short) and two on the office as built
(`end_join_curve_not_at_the_box_end`: 2056705 and 2056770, the walls of
#1474, whose bodies are centreline bodies with trims 0 so that no curve
end lies at the end of the record box the rule starts from). A marker on
a wall that already has Revit's end says the rule failed where nothing
needed doing, so a wall now carries `BodyEndRefusal` only where the
faces of the joined walls read before the refusal show its end short of
or past them (`joined_wall_face_inside_the_wall` on the same two walls
at permit qualifies); any other end the rule could not read is counted
in `exported.wall_end_reads_unmarked` and the wall carries nothing. In
the verdict run below (42119702779 on `2272c31c`) the hash of the
Snowdon file does not move and both of its walls are counted with no
marker, 1996083 among them: `main` draws it 1.03 ft short of Revit's
local export and the faces read before the refusal show no offset, so
the rule leaves a known-wrong wall with a count and no marker.

**Why one PR.** Griffin's labelled approximation was approved for "this
wall case only" (2057668 and 2057670). The base cut alone would carry
RE-337's approximate end to 2058499 and 2058501 as well, four walls on
the as-built office against two on `main`, until the order rule retired
it. Landing them apart would extend that approval for no reason, and
cost two unfiltered runs and two full CI rounds on stacked code. It is
also one set of walls: 2058499 and 2058501 as built take Revit's end
only with both.

**The order rule rests on 4 walls in one project** (8 ends), and only
the 4 as-built ends depend on the order at all: they give 3 pairwise
orderings, which the rule was fitted to after about four alternatives
had been tried; the permit ends would pass under any order. It is
fail-closed: a wall whose join list does not fit keeps the end its
record gives, with a counted `BodyEndRefusal` (an end whose record lists
no wall is not read and carries no marker; one the record trimmed is
counted when its list is not read or no curve end lies at the box's
end). The base cut rests on 2 walls in one file. The rule is on its own
release list (Revit 2024).

**#1410's volume done-when is not met and is not loosened.** After this
change the four walls' ends are Revit's at every height, and their
volume is 0.209 ft3 over Revit's as built (0.207 at permit): all of it
the far end's sloped top, which the profile line does not reach (#1473).
The wedge is 0.2088 ft3 from the record's `GLine` and the box's top, and
0.2088 ft3 is what the scorer measures on each wall. So this PR is `Refs
#1410`.

## Motivation

#1411: the BIM4LCA office's Basement walls 2058499 and 2058501 as built
stand past the edge of their footing (2058504); RE-337 kept their ends
0.31 ft short of Revit's because the longer plan would only have added
uncut base. #1410: Revit steps the ends of 2057668 and 2057670 up the
wall's height, and RE-337 omitted the second step. #1409: at building
permit the wall beneath 2058499 and 2058501 (1347201) is drawn with a
stepped profile, so RE-337 did not read its face.

## Changes

- `src/ifc/export_content/wall_tops.rs`: `decide_base` takes an element
that covers the plan in part (`covered_pieces`) only where none that
covers the whole is eligible, `base_cut_piece` splits each convex,
counter-clockwise piece of the wall into the part inside the covered
pieces, cut at the element's top, and the rest from the wall's base;
`read_end` reads an end over every height band from the plans of the
walls its record joins (`followed_wall`, including the pieces of a wall
whose top a floor cut in steps), `strips_of` draws it as the wall's plan
to its top and one column from the base for each distance the end
reaches beyond the next.
- `src/research/native_walls.rs`,
`src/research/partition_schema_mvp/walls.rs`, `fields.rs`: each wall's
location curve (`VWallDriver.m_pCrv`) and `JoinEndGStep.m_realJoined` of
each end, as fields.
- `BodyBaseSource` `wall_base_cut_at_floor_covering_in_part` and
`wall_base_sloped_at_floor_covering_in_part`, `BaseCoverRefusal`
`partly_covered_plan_not_read` and `base_cut_solid_not_made` (a cut that
resolves and whose solid cannot be made no longer leaves a silent
prism); `BodyEndSource` `wall_end_stepped_to_joined_walls`; nine new
`BodyEndRefusal` reasons, three of RE-337's kept, two gone (docs and
schema updated).
- Diagnostics: `exported.wall_end_sources`, `wall_base_sources` and
`wall_ends_order_dependent` (the ends only the order decides), and
`tools/re/wall_rule_counts.py`, which Measure runs for every model and
`scrub-holdout-results.sh` keeps as `wall rules:` count lines, so
held-out models report per-model counts.
- `decide_base`: a wall whose base join names any element that covers
the whole plan takes no partial cut, so no wall `main` cut or refused
over a whole cover changes; `covered_pieces` refuses overlapping pieces.
- Fail closed: a joined wall whose base join names elements is not read
as standing from its base.
- `tests/export_decisions_counts.rs`: the office as built no longer
witnesses `wall_base_cut_refused` and `wall_end_extension_refused`.
- `probes/examples/probe_1410_wall_end_steps.rs`, reports RE-348 and
RE-349, `docs/format-reconnaissance.md` addenda, changelog fragments
(`1410-...`, `1411-...`; `1396-...` rewritten, the approximation is gone
from it) and the support matrix.

## Testing

Unit tests are banned; measured end to end on Revit's own exports.

- [x] Verified end to end on real Revit files (both BIM4LCA office
files, CC BY-SA 4.0; scorers `wall_heights_vs_ifc`,
`wall_quantities_vs_ifc`, `wall_top_cover_vs_ifc`,
`wall_layers_vs_ifc`): the probe run 42096049754 at `a24305af`; Measure
42099826920 at `c413f382` (the base cut alone) against `main` at
`44c055db` and 42101944733 at `006f5f98` (both) against `main` at
`fb486064`. Reproduce: the commands in the reports. These runs predate
the second reads' fixes (`decide_base`, `covered_pieces`,
`base_cut_piece`, `subtract_convex`, the counters, the new reasons and
the release list), which are meant to change nothing the four walls
take; the unfiltered run on the final head is the verdict.
- Office as built: of 607 walls, 4 bodies change (2057668, 2057670,
2058499, 2058501); at permit, those four are the only bodies that
change, and 2056705 and 2056770 (same bodies) gain `BodyEndRefusal`
`joined_wall_face_inside_the_wall`: Revit cuts their end back above
182.087 ft and the rule only adds, so this is an existing error of
`main`'s, named now (their as-built siblings, 15 of 100 points taller on
`main` too with no marker, are #1474).
- The four walls have Revit's lowest point on both files (2058499 and
2058501 as built keep 174.2126 ft; at permit they go from 0.0439 ft
above Revit's to Revit's; walls with Revit's base and top at permit 587
to 589 of 589), Revit's end at every height, and no point of their plan
above Revit's top.
- Unfiltered run 42111477633 on `e5ff94f4` against `main` (`base=main
nordic=true r2025=true samples=true holdout=true`, no other filter; 111
exports, 18 of them held-out): `ifc.sha256` moved on 3 models only, the
two office files and Autodesk's Snowdon Towers Architectural; Core
Interior (wall 55840 included), Einhoven, RE1, the 24 R2025 models, the
other 57 samples and all 18 held-out models are byte-identical. **Only
the two office files take either rule**
(`wall_end_stepped_to_joined_walls` 4 as built and 4 at permit,
`*_in_part` 2 as built); no wall of the other 109 models does, so the
green `same-project gates` (success on the head: 9 samples held to their
earlier saves and the Areas on 4 saves) says nothing about these rules.
Schema: `validate` and EXPRESS `rules` findings 0 on both office files
and Core Interior, head and base (the new Compound bodies are in the
as-built file). Corpus health (witness replay, project counts),
`IfcOpenShell validates exports` and `semver checks` pass on the head.
Export time summed over 93 exports 432 s head against 449 s base; 100
job-minutes. The marker policy above came after that run. Its verdict
run, 42119702779 on `2272c31c` (`base=main nordic=true samples=true`, no
`ifc_flags`, 68 exports), moved `ifc.sha256` on the two office files
only (Snowdon's does not move), and its `same-project gates` check run
is success (9 samples held to their earlier saves, and the Areas on 4
saves and on the 2021 save). `exported.wall_end_reads_unmarked` holds
`end_join_curve_not_at_the_box_end` 2 on the office as built (2056705
and 2056770) and `joined_walls_do_not_reach_the_wall_height` 2 on
Snowdon Towers Architectural, none on any other of the 68; the office at
permit keeps its 2 marked `joined_wall_face_inside_the_wall`. No
unfiltered repeat was run, and the Revit 2025 and held-out exports are
not measured on this head: none had a refusal or a count at `e5ff94f4`,
and the policy acts only on a refusal.
- Not exercised by any measured wall: every `BodyEndRefusal` reason but
`joined_wall_face_inside_the_wall`, the high end of a wall, walls along
x, the level top of a partial cover, a partially covered wall with no
end extension, a clockwise or concave ring.

## Audit-honesty checklist

- [x] README / docs reflect the current state;
`wall_end_to_base_wall_upper_step_omitted` no longer appears in the
matrix, the diagnostics reference or schema, or the changelog's rule
description (it is named in the retirement note and in the RE-337 and
RE-349 reports as history)
- [x] User-visible changes have fragments under `changelog.d/fixed/`
- [x] New limitations are documented in the PR body, the reports and in
code (the four walls' 0.209 ft3 is #1473)
- [x] No emojis, no private paths
- [x] Reverse-engineering finding: probe under `probes/examples/`,
reports RE-348 and RE-349, addenda in `docs/format-reconnaissance.md`

## Legal and contribution hygiene

- [x] Apache-2.0; no Autodesk proprietary source (clean-room: public
bytes of the record and Revit's exported IFC bodies only)

## Breaking changes

Against `main` only, not against any release: this removes the public
constants `WALL_END_AT_BASE_WALL_BODY_END_SOURCE` and
`WALL_END_UPPER_STEP_OMITTED_BODY_END_SOURCE` and replaces the
`BodyEndSource` values they hold, and the `BodyEndRefusal` reasons
`wall_beneath_not_one_rectangle` and
`walls_beneath_reach_the_end_at_different_faces`. All of them came in
with #1398 (`b510ff3c`), which no release contains (`git tag --contains
b510ff3` is empty; v0.15.0 predates it), so no released API or output
changes. The `semver checks` job compares with `main` and accepts only
an announcement, so the footer below is for it, not a break of a
release:

BREAKING CHANGE: removes WALL_END_AT_BASE_WALL_BODY_END_SOURCE and
WALL_END_UPPER_STEP_OMITTED_BODY_END_SOURCE, unreleased constants added
by #1398; no release has them.

## Related issues

Closes #1409. Closes #1411. Refs #1410 (volume done-when not met,
#1473). Replaces #1469.
@DrunkOnJava
DrunkOnJava deleted the fix/1411-base-covered-in-part branch November 9, 2026 10:50
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

A wall base covered in part: cut over the covered part (RE-337 follow-up)

1 participant