Skip to content

fix(ifc): a rectangular wall opening in a stepped wall is written, and one whose corners do not lie in the wall's plane is left out (#1165) (RE-321) - #1310

Merged
DrunkOnJava merged 1 commit into
mainfrom
fix/1165-stepped-wall-openings
Nov 4, 2026
Merged

DrunkOnJava merged 1 commit into
mainfrom
fix/1165-stepped-wall-openings

Conversation

@DrunkOnJava

Copy link
Copy Markdown
Owner

Summary

Follow-up to #1305 from its second read, which came back after #1305 had landed. #1305's openings took only walls drawn as one extrusion, so in a wall #1304 (RE-320) draws stepped, which #1305's Measure run predates, a rectangular wall opening was left out without a word. A stepped wall keeps its whole prism as extrusion, and an opening voids every piece of its body (#1304's review checked this with IfcOpenShell), so host_of now accepts a wall whose BodyHeightSource is wall_top_stepped_at_covering_floor. An opening whose corners spread across the wall by more than 0.02 ft is now left out, which also fails closed on a wall whose axis was not read. The contribution map no longer says curtain-wall cuts and fire hose cabinets are written: #1305 withholds them.

Changes

Testing

Unfiltered Measure on this head against main (cited below once in): the office's rectangular openings must stay 30 of 30 as built and 24 of 24 at permit, extras unchanged, every other model byte-identical.

Legal and contribution hygiene

  • Apache-2.0; no Autodesk proprietary content.

Related issues

Refs #1165.

…d one whose corners do not lie in the wall's plane is left out; the contribution map says what RE-321 withholds (#1165) (RE-321)
@DrunkOnJava

Copy link
Copy Markdown
Owner Author

Automated Claude Code review (the maintainer's review agent; it read the code): no blocking items. A stepped wall's mark is set before the openings pass runs. Its opening's placement does not depend on the wall's solid shape, and walls with other solid shapes (slanted, tapered) are still refused as hosts. Measure 41758561091, on both office files, keeps every rectangular opening: 30 of 30 as built and 24 of 24 at permit, with box, GlobalId, name, type, both References and Depth equal. The 17 and 16 extras, plus the one counted apart, are unchanged.

DrunkOnJava added a commit that referenced this pull request Nov 4, 2026
…ed, where both office files keep every rectangular opening (#1165) (RE-321) (#1313)

## Summary

RE-321's office figures were measured before RE-320's stepped wall tops
(#1304) landed. #1310 then made the openings pass accept a stepped wall
as a host. This adds #1310's own run to the report, as the second read
of #1310 asked. Measure 41758561091, on both office files at cc085b4:

- **Openings:** 30 of 30 as built and 24 of 24 at permit, with box,
GlobalId, name, type, both `Reference`s and Depth equal.
- **Extras:** 17 and 16 extras plus the one counted apart, the same Tags
as in run 41748430211.

## Testing

- `tools/ci/api-doc-ids.py` passes. Docs only.

## Legal and contribution hygiene

- [x] Apache-2.0.

## Related issues

Refs #1165, #1310.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant