Repository navigation
fix(rooms): a Revit 2026 or 2027 room takes the outline of its stored solid, as on 2025 (#1260) (RE-314) - #1288
Merged
Merged
Conversation
DrunkOnJava
marked this pull request as ready for review
November 3, 2026 16:26
DrunkOnJava
enabled auto-merge (squash)
November 3, 2026 16:26
DrunkOnJava
added a commit
that referenced
this pull request
Nov 3, 2026
… the 2018 to 2021 pairs (#1260) (#1261) (#1293) ## Summary `docs/rooms.md`'s held-out rows, re-measured on `main` now that #1281 (the space scorer) and #1288 (2026 and 2027 rooms from their stored solid) have both landed: Measure [41680717786](https://github.com/DrunkOnJava/rvt-rs/actions/runs/41680717786), `main` at 21cb2ef, held-out models, counts only. ## Changes - **2026 and 2027 row:** stored solid, as on 2025. The 16 held-out rectangles are 16 of 16 in area, boundary and outline. - **Held-out 2026 house:** area within 0.1% on 10 of 12 (was 7 as boxes). Boundary and outline 0 of 12. - **New rows for the 2021 pairs held out since #1284:** - Gdynia: 18 of 19 spaces paired; area 18, boundary 0. - Warmond: 179 paired; area, boundary and outline 174. - **Spaces written for none of Revit's:** Vitoria 2018 (73), until #1286; BIM Whale 2021 (8), whose spaces are Areas. - **Removed:** "2021 projects decode with no rooms". The 2021 pairs read theirs, and BIM Whale has no rooms. ## Testing Docs only. Every figure is a count line of the cited run.
Owner
Author
|
Automated Claude Code review (the maintainer's review agent; it read the code and the Measure runs): two blocking items, fixed in 84abce0. RE-314 quoted one held-out room's area, where held-out models are quoted as counts only; it now quotes none. It also lists what follows a room's outline unscored on 2026 and 2027: furniture assignment to spaces, the room schedule CSV and the plan SVG. |
12 of 14 tasks
DrunkOnJava
added a commit
that referenced
this pull request
Nov 3, 2026
…the outline its solid's faces make, labelled stored_solid_faces or stored_solid_approximate (#90) (RE-316) (#1292) ## Summary A room whose stored solid RE-101's exact walk does not close on its record box is read again from the faces its solid lists, up to the solid's own end, and labelled apart in `SpaceOutlineSource`: `stored_solid_faces` where the faces' edges close as the walk reads them, `stored_solid_approximate` where a column overlaps a wall (its area depends on whether Revit's export takes the column off) or the outline falls up to 0.02 ft short of the box (Griffin, 2026-11-03: close them, labelled). `stored_solid` stays the exact walk's. On the BIM4LCA office as built all 13 rooms that kept their box take an outline (9 `stored_solid_faces`, 4 `stored_solid_approximate`); at building permit 11 of 12 do (all `stored_solid_approximate`). ## Motivation Rooms first (#1260): a room written as its record box where it is not a rectangle is the failure that matters. RE-313 left 12 rooms per office file on their box with the cause not found; RE-316 finds it (a record longer than 0x200 bytes between two faces, walls on lines up to 0.0015 ft apart, a column overlapping a wall, a solid longer than the 64 KB window). Round 3 of the review found room 1671995 at 323% over Revit's area (350% at permit) and asked for a guard. The 323% is the scorer's: it compares the faces of Revit's mesh that point up, and Revit's ceiling over that room is mostly not flat (1218.33 ft² in 9 patches). Revit's floor under it is 5177.37 ft² and ours 5154.12, 0.45% under; the same metric reads RE-313's 66% room (2611271) as 66% off where its floor agrees to 0.1%. See RE-316 section 3. ## Changes - `src/research/partition_room_boundaries.rs`: the span reads its edges two ways. As the walk reads them (`stored_solid_faces`: one outer loop, nested loops, no crossing, and a span bounded by the solid's list of objects and a gap of 1,024 bytes) or as the boundary of the region they wind around (`stored_solid_approximate`). Column-involved rooms are no longer labelled as the exact reading. - `tools/re/space_overlaps_vs_ifc.py` (new scorer, registered in Measure's IFC scorers; its count lines are kept for held-out models by `tools/ci/scrub-holdout-results.sh`): each space's upward-face, floor and every-face plan areas against Revit's, and how much of a room lies inside the walls and rooms around it. - Docs and labels: `docs/rooms.md`, `docs/export-diagnostics.md` (+ schema), `docs/status.md`, `docs/supported-profile.md`, `docs/evidence.md`, `changelog.d/changed/1260-room-solids-resolved.md`, `reports/element-framing/RE-316-room-solids-resolved.md`; the closure probe says why each resolved room's edges do or do not close. ## Testing Unit tests are banned in this repository: none added. End to end on Measure (commands in RE-316 section 6). - [ ] `tools/check-local.sh` passes: not run on this Mac (no local compute); CI's fmt, clippy, doc, MSRV, real-file and IfcOpenShell jobs ran green on this branch - [x] Verified end to end on real Revit files, against Revit's own IFC4 exports: the BIM4LCA office (CC BY-SA 4.0) as built and at permit with `space_profiles_vs_ifc` and `space_overlaps_vs_ifc`, room by room in RE-316 section 3; Core Interior and RE1 Architecture unchanged (116 of 116, 11 of 11); a held-out Revit 2021 project, counts only - [x] Unfiltered Measure against `main`: [41728355227](https://github.com/DrunkOnJava/rvt-rs/actions/runs/41728355227) (`-f base=main -f nordic=true -f r2025=true -f samples=true -f holdout=true`, head a00e705, base 7fd339e): scorer output differs on five files, the exports' hashes on the office, the held-out project and one `rme` room per file; nothing else - [ ] N/A: not a performance change Rooms per outline source (export diagnostics): | | `stored_solid` | `stored_solid_faces` | `stored_solid_approximate` | room `record_box` | |---|---:|---:|---:|---:| | Office as built | 221 | 9 | 4 | 0 | | Office at permit | 222 | 0 | 11 | 1 (3095831) | Area within 0.1% of Revit's export, the scorer's upward faces (before to after): office as built 221 to 230, at permit 222 to 232, Warmond (held out, counts only) 174 to 179 of 179; Core Interior and RE1 unchanged. By Revit's floor: `stored_solid` 221 of 221 and 222 of 222; `stored_solid_faces` 9 of 9 (and 6 of 6 on Warmond); `stored_solid_approximate` 0 of 4 as built (0.45% to 0.68% under) and 10 of 11 at permit (1671995, 0.45% under). **The review's four guards** (wall overlap, shell closure, volume, containment) were measured on every room the span reads. None rejects 1671995 and keeps the rooms that agree: it covers 0.03% of itself with walls (the agreeing rooms 0.10% to 7.59%, the walk's rooms up to 23%) and 0.00% of other rooms (0.00% on every room); a closed shell and the volume need the floor and ceiling faces, which `face_at` reads on 3 of the 13 rooms as built; containment holds on all. No guard is applied, no room is refused for a guard's reason. The residual (a closed loop of another element's faces inside the box and within 1,024 bytes of the last listed face) is not closed by these either; a foreign face that crosses a wall makes the room `stored_solid_approximate`. **Where this differs from the round-3 instruction:** the fallback (withhold the faces reading) would turn 1671995 and the 9 exact rooms back into boxes, which are 1.0% over Revit's floor for 1671995 and 3% to 67% over for the nine. Instead the exact label is narrowed to rooms whose edges close as the walk reads them, and every column-involved room is `stored_solid_approximate` with its measured error. Withholding it is a small change to `resolved_outline_of_solids` if the coordinator wants it. ## Audit-honesty checklist - [x] README / docs reflect the current state after this PR - [x] A changelog fragment: `changelog.d/changed/1260-room-solids-resolved.md` - [x] Limitations resolved and introduced are in RE-316 sections 3 to 5 and docs/rooms.md: the approximate rooms, the scorer's upward-face limit, the unproven foreign-face bound, the six `rac_advanced` rooms with round columns, 49 of 50 `rme` rooms, Snowdon Towers' seven and room 3095831 keep their box - [x] Commit messages describe what and why - [x] No emojis - [x] No private paths, personal email addresses or internal jargon in committed files - [x] A reproducible probe or scorer under `probes/examples/` and `tools/re/`, and a dated report ## Legal and contribution hygiene - [x] Apache-2.0 - [x] No Autodesk proprietary source, decompiled internals or NDA'd SDK content: byte observations on files Measure fetches - [x] No fixtures ## Breaking changes None to the API outside `rvt::research`. `SpaceOutlineSource` gains two values; an importer that matched `stored_solid` exactly now sees `stored_solid_faces` and `stored_solid_approximate` on rooms that were `record_box` before. ## Screenshots or output samples IFC output changes on 13 + 11 office rooms, the held-out project's 6 and one `rme` room per file: their `IfcSpace` body is the outline where it was the box. Room by room in RE-316 section 3. ## Related issues Refs #90 (rooms still drawn as their box: this resolves 13 office rooms as built and 12 at permit, and lists those that keep it: office 3095831 at permit, six `rac_advanced` rooms with round columns, 49 of 50 `rme` rooms, Snowdon's seven). #1260 (closed by #1288) is the rooms-first report that started this.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
For #1260: a Revit 2026 or 2027 room takes the outline of its stored solid, read as on 2025, instead of its record box.
partition_room_boundaries::ROOM_SOLID_SUPPORTED_REVIT_VERSIONSstopped at 2025, so on those releases every room kept its box. An L-shaped or notched room was written larger than it is (rac_basic's Master Bedroom: 35.34 m² against 26.97 m²).Motivation
inevitable-co-ai reported 7 of
rac_basic's 14 rooms larger on 2026 and 2027 than on 2015 to 2025, and a room of a 2026 house that Measure holds out (#1260). Room and space import is the first workflow being made dependable end to end (Griffin, 2026-11-03).Changes
src/research/partition_room_boundaries.rs: 2026 and 2027 join the supported releases; the doc states the measurement.reports/element-framing/RE-314-room-outlines-2026-2027.md.docs/supported-profile.md(2026 row) anddocs/support-matrix.json(2027 notes).changelog.d/fixed/1260-room-outlines-2026.md.Testing
probe_re101_room_solidswith no release gate. All 257 rooms ofrac_basic,rac_advanced,rme_basicandrme_advancedgive the same verdict and outline area in their 2026 and 2027 saves as in 2025.main, 60 models. 13 exports change: the 2026 and 2027 saves of those four samples, and the five held-out 2026 and 2027 models. The other 47 are byte-identical.Not yet measured
rac_advancedand 50 of 76 onrme_basicandrme_advanced. Another lane works on that.contain_in_spaces, point in outline);Legal and contribution hygiene
Breaking changes
None.
After review
RE-314 quotes no held-out room. Its §5 lists the unscored consequences above, and its list of identical models names the 8 other held-out ones. "Same outline" now reads "same verdict and area".
docs/evidence.mdand the 2026 support-matrix entry note room outlines.