Skip to content

feat(ifc): write walls' side areas and volumes where nothing cuts them and their body is the record's box (#1046) (RE-270) - #1162

Merged
DrunkOnJava merged 8 commits into
mainfrom
feat/1046-wall-areas
Oct 30, 2026
Merged

DrunkOnJava merged 8 commits into
mainfrom
feat/1046-wall-areas

Conversation

@DrunkOnJava

@DrunkOnJava DrunkOnJava commented Oct 30, 2026 •

Copy link
Copy Markdown
Owner

Summary

rvt-rs now writes a wall's Qto_WallBaseQuantities.GrossSideArea, NetSideArea, GrossVolume and NetVolume on the walls whose native record holds no step that cuts, embeds or sweeps the solid and whose body is the record's box cut back at its joins, a rectangle. They are Revit's on all 49 of the BIM4LCA office's such walls as built, 48 at building permit and 91 R2025 walls, none different and none Revit's export leaves out (RE-270).

Motivation

#1046 step 1 (walls). revit-ifc's CreateWallBaseQuantities (24.1 and 24.2, the office's exporter) takes the side areas from the faces of the wall's joined solid, NetVolume from its volume and GrossVolume as the type's width times the gross side area. Revit's export writes the first three exactly where it writes a Height and the NetVolume on every wall, so a body that is Revit's gives all four. This is the first slice: the walls where the record says nothing but the joins shapes the solid and the body is a plain rectangle. The rest (top joins, openings, cut pairs, layered bodies) follow as their own rules.

Changes

  • src/research/native_walls.rs, src/research/partition_schema_mvp/{fields,walls}.rs: WallRecords::whole, the walls whose record holds no step but BaseWallGStep, JoinEndGStep, VCWSplitFaceGStep, WallRefPlanesGStep, WallJoinTweakGStep and VerticalExtensionOfLayersGStep, and WALL_WHOLE_FIELD on each.
  • src/ifc/export_content.rs: add_wall_areas_and_volumes writes the four from the body's rectangle: the longer side times the height for both areas, the rectangle's area times the height for NetVolume, the written Width times the side area for GrossVolume.
  • tools/re/wall_quantities_vs_ifc.py (new scorer): meshes both files' walls and works the candidate quantities out of the faces; it pins the definitions on Revit's own bodies and sorts rvt-rs's walls by what their records hold.
  • research/witness/magnetar-2024-core-interior{,-slim}/observations/rvt-rs.json: IFCQUANTITYAREA 211 to 489 and IFCQUANTITYVOLUME 78 to 356 (139 Core Interior walls gain four quantities, counted apart: its export has base quantities off), copied from Measure's witness output.
  • RE-270, the reconnaissance addendum, docs/supported-profile.md, docs/release-1.0-criteria.md (W7), README, changelog.d/added/wall-areas-volumes.md and changelog.d/research/wall-areas-volumes.md.

Testing

Unit tests are banned in this repository; none added. Measure 41108951821: this branch (8890550, the code; the commits after it change a doc comment and the docs) against main (d1ef190), every model and every scorer. Only ifc.sha256 and qtos_vs_ifc move, apart from Core Interior's witness observations. Quantity census (tools/re/qtos_vs_ifc.py):

office as built at permit R2025 (24 models)
walls the rule selects 49 48 91
GrossSideArea, NetSideArea, GrossVolume: equal before, after 0 to 49 of 579 0 to 48 of 565 0 to 91 of 138
NetVolume: equal before, after 0 to 49 of 607 0 to 48 of 589 0 to 91 of 138
quantities equal, before 27,752 27,686 411
quantities equal, after 27,948 27,878 775
different, before and after 1 (the mullion) 1 0
written that Revit's export omits 0 0 0

The four are written on every wall of the selected 188 and on no other, so no value Revit omits is written (Revit writes all four on each). Left out and measured: walls with a top join (217 as built that have only roof or floor joins and clean joins, 163 right on the side areas and 118 on the net volume), walls with openings, cut pairs, embedded walls or sweeps (334, 71 right on the net volume), bodies from a wall's line or layers (7), and GrossFootprintArea, which Revit omits on one of the 49 as built (3184170) and one of the 48 at permit. RE-270 has the definitions pinned on Revit's own bodies, the tables, and the reproduce commands.

  • Verified end to end on real Revit files (BIM4LCA office, CC BY-SA 4.0; puzzbobb's R2025 models, Apache-2.0): Measure above, tools/re/wall_quantities_vs_ifc.py and probes/examples/probe_1067_native_dump.rs reproduce it
  • Witness observations refreshed in this PR
  • No local build: rustfmt only; CI is the gate

Audit-honesty checklist

  • README, W7, the supported profile and the reconnaissance addendum say what is and is not written
  • Changelog fragments under changelog.d/added/ and changelog.d/research/
  • Limitations (the walls left out) are in RE-270 §6 and the PR body
  • Reverse-engineering finding: scorer, probe, addendum and report included

Legal and contribution hygiene

  • Apache-2.0; clean-room: revit-ifc is read for what Revit's exporter writes and cited (CreateWallBaseQuantities), not copied

@DrunkOnJava DrunkOnJava changed the title feat(ifc): write walls' side areas and volumes where nothing cuts them and their body is the record's box (#1046) (RE-269) feat(ifc): write walls' side areas and volumes where nothing cuts them and their body is the record's box (#1046) (RE-270) Oct 30, 2026
@DrunkOnJava

Copy link
Copy Markdown
Owner Author

Owner review: add_wall_areas_and_volumes writes the four only where the wall is uncut (m_wall_uncut), whole (no record step outside HARMLESS_STEPS), drawn as its join-trimmed record box, and a plain extrusion with no profile override, and where its Width is written; all sizes finite and positive. It fails closed elsewhere. No overlap with #1152: a top join or CutPairGStep is outside the harmless steps, so no wall #1152 cuts is selected here. Measure 41108951821 (every model and scorer against main): equal 27,752 → 27,948 as built, 27,686 → 27,878 at permit, R2025 411 → 775; different unchanged (1, the mullion); nothing written that Revit omits; Core Interior's witness observations refreshed (its 139 walls' quantities are counted apart, base quantities being off in its export). Renumbered to RE-270 (aac3d5b), RE-269 being #1159's. Armed.

@DrunkOnJava
DrunkOnJava enabled auto-merge (squash) October 30, 2026 19:08
@DrunkOnJava
DrunkOnJava merged commit a866151 into main Oct 30, 2026
28 checks passed
@DrunkOnJava
DrunkOnJava deleted the feat/1046-wall-areas branch October 30, 2026 19:17
DrunkOnJava added a commit that referenced this pull request Oct 30, 2026
…e floors it is joined to leave it whole (#1046) (RE-270) (#1166)

## Summary

#1162 and #1152 are on `main`. rvt-rs now also writes a wall's
`GrossSideArea`, `NetSideArea`, `GrossVolume` and `NetVolume` on a wall
joined to roofs, floors or footings that lie clear of it, when its
record confirms its length: 18 more office walls as built and 22 at
building permit, Revit's on every one, none different and none Revit's
export leaves out (RE-270, the second rule). 2 of each are walls #1152
cuts at a floor.

## Motivation

#1046 step 1 (walls). The first rule (#1162) takes the walls nothing
joins to or cuts. Most of the rest are joined to a floor or roof at the
top. Two readings decide whether such a wall is still the prism its
record's box gives: whether the elements it is joined to leave it whole,
and whether the box's ends are Revit's. The first is measured on
rvt-rs's own bodies, the second by the record's `Length` (RE-252: the
curve cut back at its joins is as long as the curve, both ends read
twice alike). Each is needed: with the joins clear but no length, 45 of
53 office walls as built are right; with both, 18 of 18 (RE-270 §4).

## The wall top cuts (#1152)

The pass runs after `wall_tops`, on purpose (stated in
`export_content/wall_areas.rs` and at the call site): it reads each
extrusion at its final height, and a wall that pass cut has the floor's
underside for its top, which that floor then clears.

RE-267 §7 found Revit's export writes no `Height`, and so (RE-270 §1) no
side areas, on the cut walls it draws as a mesh: 1746099 and 1767978 as
built, 1488456, 1746099, 1795193 and 3363820 at permit, and nothing read
tells them from the rest. None of them gets a value: each holds a step
the rule does not allow (a cut pair or a cutout), or a body that is not
the record's box with a confirmed length (1767978 as built is drawn from
its line). The rule takes 2 cut walls in each office (2897628 and
2897629, joined to floor 2991742 alone, Revit's on all four quantities
in both files); the 3 other cut walls with a confirmed length and a
record-box rectangle (2872774, 2872775, 2872777) are also joined to slab
1875411, whose body lies inside their height, so they stay out. No cut
wall gets a value Revit omits, so no exclusion of
`wall_top_cut_at_covering_floor` walls was needed; the exclusion would
cost 2 walls in each office.

## Changes

- `src/research/native_walls.rs`,
`src/research/partition_schema_mvp/{fields,walls}.rs`:
`WallRecords::bounded`, the walls whose record holds no step but the
harmless ones, `JoinToRoofGStep` and `CleanPairGStep`, with the
ElementIds their roof and floor joins name (top and base), and
`WALL_BOUNDED_FIELD` on each.
- `src/ifc/export_content/wall_areas.rs` (new),
`src/ifc/export_content.rs`: a pass after `wall_tops` writes the four
quantities of the first rule on each such wall that carries a `Length`,
whose body is the record's box (a rectangle) and whose named elements
are slabs, roofs or footings drawn as plain extrusions lying wholly
above its top or wholly below its base. `prism_quantities` is the one
formula both rules use.
- Core Interior's witness observations (one wall more: `IFCQUANTITYAREA`
489 to 491, `IFCQUANTITYVOLUME` 356 to 358, copied from Measure's
witness output), RE-270 §4, README, W7 (its own line, as #1177 sets
out), the supported profile, the reconnaissance addendum and
`changelog.d/added/wall-areas-volumes-joined.md`.

## Testing

Unit tests are banned in this repository; none added. Measure
[41120485504](https://github.com/DrunkOnJava/rvt-rs/actions/runs/41120485504):
this branch (972d215) against `main` (6eca8e0, with #1152 and #1162),
every model and every scorer. Only `qtos_vs_ifc` and Core Interior's
witness observations move; every other scorer's output and
`diagnostics.decoded.parameter_value_count` are byte-identical to
`main`'s. Since that head, the branch only merges `main` commits that
touch no `src/` file (probes, `psets_vs_ifc.py`, the holdout scrub,
docs), so the exports are unchanged.
[41124825328](https://github.com/DrunkOnJava/rvt-rs/actions/runs/41124825328)
lists each wall (`tools/re/wall_quantities_vs_ifc.py`).

| | office as built | at permit | R2025 |
|---|---:|---:|---:|
| walls the second rule adds | 18 | 22 | 0 |
| ... of them cut by #1152 | 2 | 2 | 0 |
| walls carrying the four, with #1162's | 67 | 70 | 91 |
| the four equal to Revit's, of those | 67 | 70 | 91 |
| the four equal before, after (each quantity, of 579 and 607 as built,
565 and 589 at permit) | 49 to 67 | 48 to 70 | 91, unchanged |
| quantities equal, before | 27,948 | 27,878 | 775 |
| quantities equal, after | 28,020 | 27,966 | 775 |
| different, before and after | 1 (the mullion) | 1 | 0 |
| written that Revit's export omits | 0 | 0 | 0 |

The R2025 walls under roofs are all under sloped roofs, which rvt-rs
draws as solids and the rule does not measure. Left out and measured:
walls a floor passes through, cut pairs, cutouts, embedded walls and
sweeps (RE-270 §6).

- [x] Verified end to end on real Revit files (BIM4LCA office, CC BY-SA
4.0; puzzbobb's R2025 models, Apache-2.0): Measure above,
`tools/re/wall_quantities_vs_ifc.py` and
`probes/examples/probe_1067_native_dump.rs` reproduce it
- [x] Witness observations refreshed in this PR
- [x] No local build: `rustfmt` only; CI is the gate

## Audit-honesty checklist

- [x] README, W7, the supported profile and the reconnaissance addendum
say what is and is not written
- [x] Changelog fragment under `changelog.d/added/`
- [x] Limitations (walls a join intrudes on, sloped roofs, walls without
a confirmed length, mesh-drawn cut walls) are in RE-270 §4 and §6 and
this body
- [x] Reverse-engineering finding: scorer, probe, addendum and report
included

## Legal and contribution hygiene

- [x] Apache-2.0; clean-room: revit-ifc is read for what Revit's
exporter writes and cited (`CreateWallBaseQuantities`), not copied
Repository owner deleted a comment from chatgpt-codex-connector Bot Oct 31, 2026
Repository owner deleted a comment from chatgpt-codex-connector Bot Oct 31, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant