CLASS-16: MEP: the duct family, sloped runs, fittings and route geometry left after pipes and ducts #96
MEP fixtures (ElectricalFixture, LightingFixture,
MechanicalEquipment, PlumbingFixture, SpecialtyEquipment) are
not decoded. Required for MEP-discipline real-project parity.
Scope
Identify ElemTable tuples for each MEP category.
Decode FamilyInstance dimensions + connector geometry where
available (full route geometry deferred).
Emit IFCFLOWFITTING / IFCFLOWTERMINAL / IFCDISTRIBUTION-
ELEMENT per IFC4 mapping.
Acceptance criteria
At least 1 IFC entity emitted per MEP category present in
an MEP-discipline corpus fixture (Gate B requirement).
MEP route geometry explicitly deferred and labeled in
diagnostics.
Related
Required for ROADMAP Gate B (MEP corpus expansion)
Status, 2026-09-23. The elements in this issue's categories are now recovered from Revit 2024 and 2025 partition element records, typed by their BuiltInCategory and matched element for element against Revit's own IFC exports:
stairs: RE-39, IfcStair aggregating IfcStairFlight, landings and stringers;
railings: RE-33, IfcRailing;
structural framing: RE-36, IfcBeam;
curtain panels and mullions: RE-33, IfcPlate, IfcMember;
lighting fixtures and plumbing fixtures: RE-37 and RE-33;
specialty equipment: RE-33.
Each also carries Revit's Family:Type name where it is a family instance (RE-38, RE-42).
What this issue asks for beyond that is still open: the modelled geometry. Bodies are the element record's bounding box, or the sketched outline for slabs, not a sloped roof extrusion, stair treads, a swept railing, a beam along its curve or a curtain grid. The README's "What rvt-rs reads from real projects" table and docs/status.md have the measurements.
Milestone review, 2026-09-27: the element-emission criteria here are met on Revit 2024 and 2025 (see the status comment above). One criterion is not: the export diagnostics do not yet say which bodies fall back to the element record's bounding box. Every element carries a BodySource property, but nothing summarises it. That is #409; this issue closes when it lands. Remaining geometry (stair flight kinds, curved beams) is tracked in #357 and the 0.4.0 milestone.
Progress, measured 2026-09-27 on Snowdon Towers Architectural (an architectural model, not an MEP one): 447 IfcLightFixture, 134 IfcSanitaryTerminal and 26 IfcElectricAppliance are emitted from their element records' BuiltInCategory, with boxes as bodies (or saved display meshes with the opt-in from #255). The two acceptance criteria are still unmet: there is no MEP-discipline fixture in the reference pack (#407) to measure one entity per category against, and route geometry is not yet labelled as deferred in the diagnostics. Needs an openly licensed MEP model.
Activity
DrunkOnJava commentedon Aug 29, 2026
Re-baseline 2026-08-29: Backlog only (1.0.0). MEP equipment decoders unsupported; project-count fixtures still expect 0 IFCFLOWTERMINAL on Core Interior.
DrunkOnJava commentedon Sep 23, 2026
Status, 2026-09-23. The elements in this issue's categories are now recovered from Revit 2024 and 2025 partition element records, typed by their
BuiltInCategoryand matched element for element against Revit's own IFC exports:IfcCovering.CEILING.;IfcRoof;IfcStairaggregatingIfcStairFlight, landings and stringers;IfcRailing;IfcBeam;IfcPlate,IfcMember;Each also carries Revit's
Family:Typename where it is a family instance (RE-38, RE-42).What this issue asks for beyond that is still open: the modelled geometry. Bodies are the element record's bounding box, or the sketched outline for slabs, not a sloped roof extrusion, stair treads, a swept railing, a beam along its curve or a curtain grid. The README's "What rvt-rs reads from real projects" table and
docs/status.mdhave the measurements.DrunkOnJava commentedon Sep 27, 2026
Milestone review, 2026-09-27: the element-emission criteria here are met on Revit 2024 and 2025 (see the status comment above). One criterion is not: the export diagnostics do not yet say which bodies fall back to the element record's bounding box. Every element carries a BodySource property, but nothing summarises it. That is #409; this issue closes when it lands. Remaining geometry (stair flight kinds, curved beams) is tracked in #357 and the 0.4.0 milestone.
feat(diagnostics): count exported bodies by how they were derived, an…
DrunkOnJava commentedon Sep 27, 2026
Progress, measured 2026-09-27 on Snowdon Towers Architectural (an architectural model, not an MEP one): 447 IfcLightFixture, 134 IfcSanitaryTerminal and 26 IfcElectricAppliance are emitted from their element records' BuiltInCategory, with boxes as bodies (or saved display meshes with the opt-in from #255). The two acceptance criteria are still unmet: there is no MEP-discipline fixture in the reference pack (#407) to measure one entity per category against, and route geometry is not yet labelled as deferred in the diagnostics. Needs an openly licensed MEP model.
65 remaining items