Skip to content

CLASS-12: Roof + Ceiling decoders + IfcRoof / IfcCovering emission #92

Closed

Description

@DrunkOnJava

Problem

Roofs and ceilings are not yet decoded. CHANGELOG [0.2.0] entry
#79 added a "Roof tiebreaker" tuple disambiguation but no Roof
class is yet emitted. Ceilings have no path at all.

Scope

  • Identify Roof + Ceiling ElemTable tuples.
  • Roof: boundary profile + pitch + thickness -> sloped extrusion
    -> IFCROOF.
  • Ceiling: boundary profile + level offset -> planar extrusion
    -> IFCCOVERING with PredefinedType=.CEILING.
  • Material associations (per RE-15-08 pattern for walls).

Acceptance criteria

  • At least 1 IFCROOF entity emitted per corpus file with roofs.
  • At least 5 IFCCOVERING(CEILING) entities per file with
    ceilings.
  • Per-storey routing correct (roofs/ceilings nested under right
    storey).

Related

Activity

  1. added
    area:elements
    area:ifc
    area:partitions
    priority:P2
    type:feature
    on May 23, 2026
  2. DrunkOnJava commented on Aug 29, 2026

    @DrunkOnJava
    OwnerAuthor

    Re-baseline 2026-08-29: CLASS-* stretch goals remain open but are behind typed architectural recoveries and RE walls (Door/Window/schema Wall). Do not schedule as near-term MVP. Labels/milestones can stay; treat as post-evidence backlog only.

  3. self-assigned this
    on Aug 30, 2026
  4. DrunkOnJava commented on Sep 23, 2026

    @DrunkOnJava
    OwnerAuthor

    Status, 2026-09-23. The elements in this issue's categories are now recovered from Revit 2024 and 2025 partition element records, typed by their BuiltInCategory and matched element for element against Revit's own IFC exports:

    • ceilings: RE-33, IfcCovering .CEILING.;
    • roofs: feat(elements): export roofs from element records as IfcRoof (#323) #326, IfcRoof;
    • stairs: RE-39, IfcStair aggregating IfcStairFlight, landings and stringers;
    • railings: RE-33, IfcRailing;
    • structural framing: RE-36, IfcBeam;
    • curtain panels and mullions: RE-33, IfcPlate, IfcMember;
    • lighting fixtures and plumbing fixtures: RE-37 and RE-33;
    • specialty equipment: RE-33.

    Each also carries Revit's Family:Type name where it is a family instance (RE-38, RE-42).

    What this issue asks for beyond that is still open: the modelled geometry. Bodies are the element record's bounding box, or the sketched outline for slabs, not a sloped roof extrusion, stair treads, a swept railing, a beam along its curve or a curtain grid. The README's "What rvt-rs reads from real projects" table and docs/status.md have the measurements.

  5. DrunkOnJava commented on Sep 27, 2026

    @DrunkOnJava
    OwnerAuthor

    Closing against the acceptance criteria above, rechecked on main (ebba730), 2026-09-27:

    • IfcRoof on every file with roofs: Snowdon Towers exports its 20 roofs, each a Tag in Revit's own IFC4 export (feat(elements): export roofs from element records as IfcRoof (#323) #326, RE-50).
    • At least 5 IfcCovering .CEILING. per file with ceilings: Snowdon Towers 68 (RE-33).
    • Per-storey routing: Snowdon Towers 5,949 elements in the storey Revit's export gives them, 1 in another, 1 on none (RE-27, RE-59, RE-60, RE-68).

    Beyond the criteria, roofs carry their sketched outline (13 of 20, 11 with Revit's area, RE-50) and a shed roof is drawn along its slope (RE-56). Hip and gable roofs remain level plates; that residual is #356.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

Labels

area:elementsarea:ifcarea:partitionspriority:P2type:feature

Type

No type

Projects

No projects

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions