You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Roofs and ceilings are not yet decoded. CHANGELOG [0.2.0] entry #79 added a "Roof tiebreaker" tuple disambiguation but no Roof
class is yet emitted. Ceilings have no path at all.
Re-baseline 2026-08-29: CLASS-* stretch goals remain open but are behind typed architectural recoveries and RE walls (Door/Window/schema Wall). Do not schedule as near-term MVP. Labels/milestones can stay; treat as post-evidence backlog only.
Status, 2026-09-23. The elements in this issue's categories are now recovered from Revit 2024 and 2025 partition element records, typed by their BuiltInCategory and matched element for element against Revit's own IFC exports:
stairs: RE-39, IfcStair aggregating IfcStairFlight, landings and stringers;
railings: RE-33, IfcRailing;
structural framing: RE-36, IfcBeam;
curtain panels and mullions: RE-33, IfcPlate, IfcMember;
lighting fixtures and plumbing fixtures: RE-37 and RE-33;
specialty equipment: RE-33.
Each also carries Revit's Family:Type name where it is a family instance (RE-38, RE-42).
What this issue asks for beyond that is still open: the modelled geometry. Bodies are the element record's bounding box, or the sketched outline for slabs, not a sloped roof extrusion, stair treads, a swept railing, a beam along its curve or a curtain grid. The README's "What rvt-rs reads from real projects" table and docs/status.md have the measurements.
At least 5 IfcCovering .CEILING. per file with ceilings: Snowdon Towers 68 (RE-33).
Per-storey routing: Snowdon Towers 5,949 elements in the storey Revit's export gives them, 1 in another, 1 on none (RE-27, RE-59, RE-60, RE-68).
Beyond the criteria, roofs carry their sketched outline (13 of 20, 11 with Revit's area, RE-50) and a shed roof is drawn along its slope (RE-56). Hip and gable roofs remain level plates; that residual is #356.
Activity
DrunkOnJava commentedon Aug 29, 2026
Re-baseline 2026-08-29: CLASS-* stretch goals remain open but are behind typed architectural recoveries and RE walls (Door/Window/schema Wall). Do not schedule as near-term MVP. Labels/milestones can stay; treat as post-evidence backlog only.
DrunkOnJava commentedon Sep 23, 2026
Status, 2026-09-23. The elements in this issue's categories are now recovered from Revit 2024 and 2025 partition element records, typed by their
BuiltInCategoryand matched element for element against Revit's own IFC exports:IfcCovering.CEILING.;IfcRoof;IfcStairaggregatingIfcStairFlight, landings and stringers;IfcRailing;IfcBeam;IfcPlate,IfcMember;Each also carries Revit's
Family:Typename where it is a family instance (RE-38, RE-42).What this issue asks for beyond that is still open: the modelled geometry. Bodies are the element record's bounding box, or the sketched outline for slabs, not a sloped roof extrusion, stair treads, a swept railing, a beam along its curve or a curtain grid. The README's "What rvt-rs reads from real projects" table and
docs/status.mdhave the measurements.DrunkOnJava commentedon Sep 27, 2026
Closing against the acceptance criteria above, rechecked on main (ebba730), 2026-09-27:
Beyond the criteria, roofs carry their sketched outline (13 of 20, 11 with Revit's area, RE-50) and a shed roof is drawn along its slope (RE-56). Hip and gable roofs remain level plates; that residual is #356.